1. CPU function
As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB.
2. Built-in analog input and output (alarm output by the way)
Built-in 12-bit 2-channel analog input and 1-channel analog output.
Parameters can be used to set the transmission of values, the scale of the scale, and the alarm output.
3. Built-in SD memory
The built-in SD card slot is very convenient for mass production of program upgrades and settings.
4. Built-in RS-485 port (with MODBUS function)
Corresponding to the MODBUS function, it can be connected to PLC, sensors, temperature regulators and other peripheral equipment, and can be connected to 32 units.
5. Safety
The MELSEC IQ-F can use security functions (file code, long-distance code, security code) to prevent unauthorized access by third parties and unauthorized data theft and illegal execution.
6. High-speed system bus
The MINELC IQ-F is equipped with a high-speed CPU and achieves a communication speed of 1.5K bytes/ms (about 150 times that of the FX3U), which can be used to the maximum even when expanding multiple modules.
7. No battery required, simple protection
The program can be maintained without batteries, and the timer data can be held for 10 days through a large capacitor
8. Built-in Ethernet port
The Ethernet communication port is the largest on the network, capable of connecting up to 8 computer devices, and can correspond to the protection of long-distance equipment or seamless SLMP communication between host computers.
9. Advanced positioning function
Built-in 4-axis, 200KHZ positioning function. It can be used to complete the function of abort positioning, variable speed operation, and simple interpolation through special instructions.
10. Advanced motion control function
|
More on that
|
The correct maintenance method for Mitsubishi inverters
Mitsubishi inverter we have to maintain the inverter module frequently, to regularly check the Mitsubishi inverter module, especially the maintenance of the cooling fan, due to the high power of the cooling fan, high speed, in the dusty working environment, simply lead to the radiator exhaust hole blockage, so that the internal electric ...
|
|
An introduction to the types of data inside the Mitsubishi FX series
A lot of data is used in the internal structure of the PLC and in the user's use program. These data have the following forms in terms of structure or number system.
(1) Decimal number
Decimal numbers are also known as word data in PLC. It is first and foremost ...
|
|
Mitsubishi FX5U series PLC ten advantages
1. CPU function
As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB.
2. Built-in analog input and output (alarm output by the way)
Built-in 12-bit 2-channel analog input ...
|
|
Mitsubishi servo motor for precise positioning
The servo?mechanism is a process control system that enables the output of the direction, direction, and condition of the block to change at will according to the input overall goal (or given value).
How to finish the Mitsubishi servo motor ...
|
|
PLC commonly used physical memory - Mitsubishi
(1) Random Access Memory (RAM) The user can read out the content of the RAM with the programming device, and can also write the user program to the RAM, so the RAM is also called read/write memory. It is volatile memory, and when its power is interrupted, the stored information is lost. The use of the computer's memory module ...
|
|
Mitsubishi servo selection robot method
When evaluating which process is suitable for which process to use in the production environment, it is necessary to carefully consider the problem you want to solve and consider all the costs that the robot can save: reduce waste, improve power, improve yield, improve safety or reduce labor costs. These costs ...
|
|
There are three major classifications of inverters - Mitsubishi inverters
There are several ways to classify frequency converters:
According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter;
In accordance with the ...
|
|
Mitsubishi FR-E540 inverter parameter settings
1. Press the mode button continuously until you enter the parameter writing state, and the LED display is: Pr.O
2. Press the upper button to adjust the parameter to the Pr.34O parameter.
3. Press SET, the LED displays the initial value of Pr.340, press ...
|
|
The protection function of the inverter to the motor - Mitsubishi
The inverter is the control equipment for the operation of the motor, and it has a certain maintenance function for the motor. Most of the inverter appliances have functions such as overvoltage, overcurrent, undervoltage and overload maintenance.
Overcurrent maintenance function. In any link of motor acceleration, deceleration and constant speed operation, ...
|
|
The relationship between torque and performance of Mitsubishi servo motors
1. Additional torque
The torque that occurs on the motor shaft under additional voltage, extra load is called the extra torque of the motor.
2. Starting torque
The torque generated by the motor at the moment when a voltage is applied to the motor in the aborted condition is called the starting torque. The starting torque characterizes the electrical...
|
|
Z series and A200 series inverter fault solving
Low-power Z024 series inverter, our common problems include OC, ERR, no appearance, etc. There are two possible causes of OC.
(1) Aging of the drive circuit
Because the use of a long period of time will inevitably lead to the aging of components, which will cause the driving waveform to occur.
|
|
The origin of Mitsubishi servo motion control is returned
1. The so-called positioning is to let the servo motor go to a confirmed position.
2. This direction can be so incremental, or so ***. For example, we are now on the road, and we have to go forward 10 meters, which is equivalent to adding 10 meters to our bearing.
|
|
Mitsubishi PLC communication detection steps
When you are ready to communicate through AJ71QE71, perform the ping procedure in MS-DOS mode to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. Support communication with Weilun touch screen through serial port.
...
|
|
Introduction to the principle of Mitsubishi tension controller
The tension controller can be called the tension manipulator, which is generally equipped with magnetic powder brake, magnetic particle clutch and tension detector, and is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the ability to give a certain amount of output through the tension manipulator ...
|
|
How does Mitsubishi PLC work?
1. A scanning cycle is divided into input sampling, program fulfillment, and output rewriting.
2. Each scan process. The convergence samples the input signal. The convergence rewrites the output signal.
3. The inner ...
|
|
PLC control system daily maintenance process - Mitsubishi
After overhauling and confirming that all connections of the system are accurate, power on the relevant modules until the card indicator is normal.
The initiation process of the system after the scheduled repair is as follows:
(1) Power supply. Open power supply equipment (including throwing up...
|
|
The connection of the Mitsubishi inverter FR-A800
The connection of the Mitsubishi inverter FR-A800
|
|
Advantages and disadvantages of different output types of PLC – Mitsubishi
The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types?
(1) Transistor output:
The big advantage is that it is accustomed to high-frequency action, and the echo time is short, generally about 0.2ms, but ...
|
|
Power factors affecting Mitsubishi inverters
The speed regulation of Mitsubishi inverter power regulator is adopted, one is to regulate the speed according to the requirements, and the other is to save energy. It is based on the following elements:
1) The frequency conversion speed regulation system has low loss and high operating power.
2) The motor is always kept running at a low slip rate, which reduces the rotor loss.
|
|
The difference between Mitsubishi FX3u and FX5u
Mitsubishi FX3U series PLC is the third generation of miniature programmable manipulators, using a class of programmable memory for its internal storage programs, to execute logic operations, sequence control, timing, counting and arithmetic operations and other user-oriented instructions, and through digital or analog input/output control of each ...
|
|