What happens when the inverter-controlled motor presses the abort button, and the motor is not controlled to speed up?
1. If it is a newly installed inverter, it is generally necessary to consider the wiring problem, you can first change the parameters to switch to the panel control, the panel gives the frequency, and then see if the inverter operation will have this kind of problem, if not, you can be 100% sure that it is caused by wiring fault, if the panel operation has this situation, it is clear that it is caused by the internal problem of the inverter or the load problem.
2. If there is a PLC or other device to control the inverter, this is the need to find the problem from the whole system, if it is a newly installed PLC, not to sweep is caused by incorrect programming logic, this can be diagnosed online start and stop signal and frequency given signal to find out the problem. If there is communication at the same time, there is analog and /0 manipulation, which may cause logical disorder to form together.
3. If it is the linkage of multiple inverters, involving some synchronous stretching actions and the like, or some coiling systems, the inverter controls the motor to operate in the vector torque mode, and the parameters are not adjusted, resulting in the loss of torque control during parking and causing the motor to stall, this situation is more common in the debugging process, because the motors will pull each other, there is a certain balance force, a certain shutdown, will be pulled by other in the opposite direction to speed up, or the reaction force of some elastic data is instantly formed.
4. Some multi-functional European and American inverters, there are a lot of functional modules, many of its /0 can be programmed to set the start and stop, the parameters are confused, although you follow the factory start and stop terminal to wiring, but the function has changed, although your abort signal input, but not the abort signal inside the inverter, but become a speed signal, at this time you need to restore the factory value to reset.
5. The inverter motherboard is broken, for example, there is a problem with the 1/0 handling chip, and the inverter has been out of control, which is relatively rare, but it also exists, and the special shortcomings of some power supply are damaged, which may cause this problem.
6. Disturbance problem, this situation is mostly generated in some workshops with a lot of dust, the inverter is used for a long time, and some disordered conductivity is formed in the accumulation of a lot of dust, or there is some static electricity that causes the inverter to operate out of control, at this time, the disassembly and cleaning of the inverter can generally solve the problem, or the strong electrical signal of the inverter output main circuit and //O is not separated during wiring, and it needs to be separated.
|
More on that
|
Inverter-related knowledge - Senlan inverter
1. What does open-loop mean in the use of inverters?
The speed detector (PG) is installed on the motor equipment in operation, and the speed response of the actual speed is sent to the control equipment, which is called "closed loop", and the speed detector that does not use PG is called "open loop". Most general-purpose drives are open-loop ...
|
|
Failure of robot contactor and inverter - Senland
Robot contactors are noisy?
Cause:
It is likely that the joint contact surface of the contactor is uneven, and the surface is sand or rust. The result will constitute a phase loss, which will lead to the burnout of contactors, switch frequency conversion and other components.
Solution:
will control the ...
|
|
Inverter braking resistance connection method - Senlan inverter
If the drive has a built-in braking unit and additional braking resistors, it is important to pay attention to the correct wiring of the braking resistors. The braking resistor should be connected between the P terminal and the DB terminal, but not between the P terminal and the N terminal, otherwise the three-phase rectifier bridge will operate at full load when it is not running, resulting in the equipment can not be ...
|
|
Senlan inverter selection points
1. Select the inverter according to the load characteristics, such as the load is constant torque load, you can choose Siemens MM440 inverter, ABB ACS800 series inverter, etc.; If the load is a fan or pump load, you can choose Siemens MM430 inverter, ABB ACS510 series inverter, etc.
2、 ...
|
|
Sunland inverter electromagnetic interference suppression method
When the peripheral equipment and the inverter share the same power supply, the disturbance generated by the inverter is transmitted against the power line, which will cause other equipment in the same system to malfunction. The following methods can be adopted:
(1) The input device of the inverter is equipped with an EMI filter or a ferrite common-mode filter (magnetic ring) ...
|
|
Misunderstandings and countermeasures of industrial control inverter - Senlan
Today, with the rapid development of science and technology, with the continuous improvement of industrial automation, inverters have also been widely used. Choosing a suitable inverter is very important to ensure the normal and efficient work of the inverter, but in practice, it is necessary to pay attention to some ...
|
|
Inverter water inlet maintenance method - Sunland inverter
The first step is not to turn on electricity! First open the inverter panel, wipe the inverter dry, and then use a hair dryer to dry the display, PC board, push board, power components, fans, etc., with 95% alcohol, scrub the components with 95% alcohol, and dry the hair dryer with cold air.
Step 2: After an hour, use alcohol ...
|
|
Hope Sunland inverter application introduction
1. Motor control
The inverter is mainly used in the field of motor control, which can complete the speed control, torque control, and azimuth control of the motor. The inverter can adjust the speed and load of the motor according to the process requirements, which can improve the output power and quality.
2. Air conditioning refrigeration
...
|
|
Get to know the capacitor of the inverter - Sunland inverter
1. The capacitance is generally indicated by "C" plus a number in the circuit (e.g., C25 indicates the capacitance numbered 25).
A capacitor is a component composed of two metal films close to each other and separated by an insulating material in the center. The characteristic of the capacitor is first and foremost the communication through the DC block. The size of the capacitance is ...
|
|
The method of heat dissipation of small-capacity inverter - Sunland inverter
Natural heat dissipation methods are generally used for heat dissipation of small-capacity inverters, because their operating environment should be well ventilated and free of dust and floating objects. The drag targets of such inverters are mostly household air conditioners, CNC machine tools, etc., and the power is small.
Still...
|
|
Inverter interference solution - Sunland inverter
1. Make proper grounding
After a detailed investigation of the site, we can see that the grounding situation on the site is not very ambitious. The correct grounding can not only be useful for the system to press the external disturbance, but also to reduce the disturbance of the equipment itself to the outside world, which is the most useful for dealing with the disturbance of the inverter.
|
|
Motor inverter principle and precautions for use - Senlan
The difference between a voltage converter and a current converter
Voltage inverter and current inverter are two different operating principles, for example, the operating principle of voltage inverter is mainly to regulate the voltage source, and the voltage source regulates the current to achieve the effect of conditioning, while the current inverter is a direct ...
|
|
The reason for using frequency conversion speed regulation - Senlan
Now, the frequency conversion speed regulation system has been widely used in the industrial production of various small and medium-sized enterprises. This is all due to our ability to provide accurate speed control and complete stepless speed regulation. Therefore, it can easily control the ascent and descent of mechanical transmissions, traverse ...
|
|
The reason for the explosion of the inverter module - Senlan inverter
1. Condensation The temperature difference in the workshop is large, and the inside of the inverter presents condensation.
2. Impact load. The load fluctuates greatly, and the output current of the inverter suddenly increases, resulting in module damage.
3. The inverter is overloaded in the start, ...
|
|
How to expand the application range of inverter - Sunland inverter
In the electrical profession, the use and development of energy-saving frequency conversion is very good, which has promoted the electrical profession to reach the pinnacle of science and technology again. Frequency converter (VFD) has a very good development shape in China, but it still has to withstand various tests. As long as you give full play to your professional advantages, you can gain a firm foothold in this society. VFD ...
|
|
The remote control of the inverter meets the function - Sunland inverter
In general, the long-distance operation of the frequency converter requires the following functions:
1) Long-distance setting, if the parameters only need to be set for the first time, and do not need to be adjusted during operation, then long-distance setting is not required.
2) Long-distance start-stop, long-distance start or stop inverter, and ...
|
|
Inverter control method for motor - Senlan
1. U/f stable control
U/f control is to change the voltage of the motor power supply together with changing the frequency of the motor power supply, so that the magnetic flux of the motor is kept constant, and the efficiency and power factor of the motor do not decrease within a wide range of speed regulation. Because it is to control the voltage and frequency ...
|
|
Advantages of Senlan vector control system
Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed.
At low frequencies ...
|
|
Suppression method of electromagnetic interference of inverter - Sunland inverter
The operating principle of the inverter determines that it will have a certain disturbance, which may bring EMC (electromagnetic compatibility) problems to the equipment or system, and the inverter, as an electronic device, will also be affected by external electromagnetic disturbance.
Below...
|
|
Differential overhaul method of inverter - Senlan
For the dual requirements of anti-interference and galvanic isolation, the pre-circuit of the output current detection or voltage detection of the inverter usually uses the "matching" circuit of the linear optocoupler device and the differential amplifier to complete the transmission mission of the detection signal. The circuit of the differential amplifier is based on the current detection circuit ...
|
|