1. Closed busbar hooking technology
The circuit breaker and contactor can be hooked on the bus through the bus adapter, and the fuse switch and other products are directly attached to the bus, so the bus plays a two-layer effect of conductive and fixed rotation, which greatly saves the space in the cabinet; At the same time, other components of the bus system ensure that the bus system is fully enclosed, which is both safe and beautiful;
2. No perforated connection
Perfectly deal with the problem of user power supply inlet, the cable main inlet and bus system in the cabinet, or the connection of cables and switches, circuit breakers and other components, do not need to do a wire nose, just peel off the outer skin and directly crimp the connection.
3. High current, multi-circuit, high power distribution level
Regarding the application occasions where there are many power distribution and control loops, the current is relatively large, and the system is required to operate safely and safely, Wiener products are handled vividly with bus system technology.
|
More on that
|
Characteristics of the common box closed busbar - Wiener
The common box closed bus includes the non-phase isolated, common box closed bus, phase isolated common box closed bus and AC and DC excitation common box bus, which are used for current transmission between the generator lead wire below 100MW and the low-voltage side of the main transformer or between the low-voltage side of the transformer and the high-voltage distribution device of the unit of 75MW and above.
|
|
Fast protection of medium and low voltage busbars – Wienal
1.It is necessary to install arc light maintenance
Arc maintenance in foreign countries has nearly 20 years of history, the first set of maintenance devices in 1995 has been put into operation, China's previous imported units in the introduction of foreign complete sets of arc light maintenance (such as Guohua Tianjin Panshan Power Plant), domestic units ...
|
|
Development of the busbar trunk system – Wiener
(1) Air-type busway
Since the mid-50s of the last century, represented by Beijing Baizhifang Airport Electrical Appliance Factory, the conductive row has been supported in the shell with insulating liner and insulated by air medium. The phase-to-phase distance is 50mm.
(2) Secret ...
|
|
Introduction to the Wiener busbar system
The 60mm bus system refers to the three- or four-wire bus spacing of 60mm.
In the 60mm bus system, the different cross-sectional areas of rectangular copper bars or special-shaped copper busbars such as 2T and 3T can be used to achieve the optimal distribution of current intensity levels, ...
|
|
What is the role of the busbar in the distribution box
Busbar refers to a product made of copper and aluminum materials with high conductivity to transmit electrical energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transport electrical energy. In the power system, the busbar in the distribution box connects the various current-carrying branch circuits in the distribution unit, ...
|
|
The difference between busway and busbar - Vernal
The busway and busbar are actually closed one after the other, and the other is not closed.
Closing the busbar is referred to as the busway, which means that the busway is the vest that closes the busbar, and the closing busway and the busbar refer to the same thing.
...
|
|
Wiener is a common way to wiring busbars
Single bus wiring method: all outgoing wires are connected to the same busbar, which is also the most cost-effective and simplest wiring method
Single bus segmentation: The outgoing line is arranged in two parts on different sections of the single busbar, so that a power failure in the meantime does not affect the power supply of the other bus
...
|
|
There are several main ways to wiring the Wiener bus
Bus line refers to a product made of copper (copper bar) and aluminum material with high conductivity to transmit electrical energy and have the ability to collect and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the output of the generator, transformer or rectifier ...
|
|
How to choose the right fuse - Wiener
1. Select the type of fuse according to the line requirements and installation conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses.
...
|
|
Rectangular busbar, trough busbar, and tubular busbar analysis
The rectangular bus has good heat dissipation performance and is easy to fix and connect. But its skin effect is quite large. In order to reduce the skin effect, the cross-sectional area of a single busbar should not exceed 1250 square millimeters. When the working current exceeds the promised current of a single bus, 2 to 4 rectangular buses can be used. Rectangular conductor a ...
|
|
Detailed explanation of Wiener DC bus
1. Three-phase AC power supply inlet
The power input of each inverter is connected in parallel on the same AC bus, and the power phase of the input end of each inverter is ensured. The circuit breaker QF is the incoming line protection device for each inverter. LR is an incoming reactor, when multiple inverters are operating in the same environment.
|
|
Wiener plug-in busway features
The plug-in busway has a high overload capacity
The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105C is selected for the insulation material used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed ( ...
|
|
Busbar system reverse operation – Wiener
(1) For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...
|
|
The Hazards of Arc Light – Wiener Busbar System
The arc of the switchgear cable spacing causes the pressure and temperature in the switchgear to increase rapidly, and if not removed in time, it will cause serious harm in the following aspects:
(1) The arc temperature is 2 times the appropriate solar temperature, and the large ...
|
|
Conductor and bus welding requirements - Wiener
1. Before welding, it is necessary to check whether the welding equipment is defective, whether the grounding of the electrical equipment is reliable, and strictly abide by the "welder safety operation procedures" when welding.
2. Correct wires and busbars, and prohibit the use of handleless files.
...
|
|
Application and technical requirements for bus protection on the low voltage side - Wiener
1. The use status of bus maintenance on the low-voltage side
According to the national standard "Code for Relay Maintenance and Automatic Equipment Design of Power Equipment" (GB50062-92): about the 3-10kV bus and the double bus running in parallel of the power plant and the primary substation, as long as the following conditions are installed.
|
|
Precautions for installation of Wiener busway
1. Before the bus duct installation, it should be ensured that the electrical shaft, substation and distribution room, the decoration project of the place through which the bus duct passes, and the heating and ventilation project are all completed to ensure that the bus duct is not polluted. The reserved holes and embedded parts of the floor and wall should be embedded and reserved according to the position required by the design. The functions of the busway are single ...
|
|
Wiener bearing repair technology
1. Comprehensive correction of bearings
The comprehensive correction of the bearing includes the comprehensive and strict correction process of the damaged bearing after cleaning, dismantling, inspection, roller table grinding or replacement of inner and outer rings, new rolling element manufacturing/original rolling element grinding, rolling element replacement, assembly, clearance adjustment and inspection and packaging.
|
|
The busway power system is a key component - Wiener
The busway is one of the more critical components in the power system, and it is an important part of connecting cables to important equipment such as substations, overhead lines, transformers, circuit breakers, etc. It is widely used in various power systems, mainly for the reliable operation of power systems.
...
|
|
Venal common bus scheme applicable places and precautions
When multiple inverters are used in the common DC bus, because the DC bus between the inverters is connected together, the bus energy between the inverter in the power generation operation state and the inverter in the electric operation state can flow to each other, so that the voltage of the common bus remains relatively stable, and the body ...
|
|