Functions of input/output pins P0, P1, P2, P3 – Schneider

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

P0.0——P0. 7 : Port P0 is an 8-bit open-drain bidirectional I/O port. When visiting off-chip memory, it is time-shared for a low-8-bit address and an 8-bit bidirectional data bus. When EPROM is programmed, the instruction byte is input by P0, and when the program is verified, the instruction byte is output. When verifying the program, an external pull-up resistor is required. P0 can drive 8 LSTTL loads by soaking current.

                                 Functions of input/output pins P0, P1, P2, P3 – Schneider

P1. 0 ——P1. 7 (1-8 pins): P1 is an 8-bit bidirectional I/O port with an internal pull-up resistor. When EPROM is programmed and validated by the program, it enters the lower 8-bit address. P1 can drive 4 LSTTL loads.

In 8032/8052, P1. 0 is also equivalent to the dedicated utility terminal T2, which is the count-triggered input of the timer; P1. 1 is also equivalent to the dedicated utility terminal T2EX, which is the external control end of timer T2.

P2.0 – P2.7 (21 – 28 pins): P2 is also an 8-bit bidirectional I/O port with an internal pull-up resistor. When visiting external memory, it outputs an 8-bit higher address. When programming and verifying the EPROM, it enters an 8-bit higher address. P2 is capable of driving 4 LSTTL loads.

P3. 0 ——P3. 7 (10-17 pins): P3 is also a bidirectional I/O port with an internal pull-up resistor. In the MCS-51, these 8 pins are also used for a dedicated secondary function. The P3 can drive up to 4 LSTTL loads.

P3. 0 RXD (Serial Port Input)

P3. 1 TXD (Serial Port Output)

P3. 2 INT0 (External Abort 0 Input)

P3. 3 INT1 (External Abort 1 Input)

P3. 4 T0 (external input for timer 0)

P3. 5 T1 (external input for timer 1)

P3. 6 WR (off-chip data memory write gating)

P3. 7 RD (off-chip data memory read gating)

More on that
Schneider UPS power supply preventive maintenance precautions Schneider UPS power supply preventive maintenance precautions

1 Contingency plan Contingency plans are the top priority of preventive protection. Arrangements need to be better partnered with service providers to be part of the corporate programme. This means implementing processes and procedures for every type of thing, including contingency plans. ...

Schneider miniature circuit breaker problem analysis and answer Schneider miniature circuit breaker problem analysis and answer

Fault 1: The shell of Schneider MCB product is yellowed or burned. Reason 1: It is very likely that the magnetic coil inside the circuit breaker is burned out because of harmonics or high-frequency signals. Method 1: * The good thing is that the filtering can be satisfied with the use of 50Hz/60Hz power frequency. ...

About the characteristics of Schneider explosion-proof inverter cabinet About the characteristics of Schneider explosion-proof inverter cabinet

1. Aluminum alloy shell or steel plate welding, surface spraying; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; 3. It mainly regulates ordinary three-phase by changing its output frequency ...

Automatic control instrument construction content and procedures - Schneider Automatic control instrument construction content and procedures - Schneider

1. Construction preparation. Including the preparation of operating conditions (construction skills documents and detailed planning documents), construction organization planning, equipment list, data budget, and list of machined parts; 2. Cooperate with civil engineering majors to do a good job of embedding, ...

Schneider intermediate relays Schneider intermediate relays

  Schneider 24VDC intermediate relays are the most common components in control systems. Generally, 2 normally open and 2 normally closed are the most commonly used, but sometimes 4 normally open and 4 normally closed contacts are not enough. Both have different coil and base models. ...

For the first time, Schneider presents a new lightweight MES in packaging For the first time, Schneider presents a new lightweight MES in packaging

Packaging Lightweight MES is a production line and workshop-level digital management and processing solution created by Schneider Electric based on more than 20 years of experience in packaging machine automation, combined with the digital transformation needs of the FMCG (Consumer Packaged Goods) profession, which can be widely used in food and beverage, life ...

Dual-fan inverter selection - Schneider Dual-fan inverter selection - Schneider

1. Qualified after inspection When selecting a double fan inverter, it must be strictly checked for its quality. The first requirement is that it must have relevant certificates of qualified inspection, and some qualified materials must be taken out. This is the only way to ensure that this change ...

There is no indication on the UPS boot panel that UPS is not working - Schneider There is no indication on the UPS boot panel that UPS is not working - Schneider

Fault analysis: judging from the fault phenomenon, the fault is in the mains input, battery and mains detection part and battery voltage detection loop: 1. Check whether the mains input wire is incinerated; 2. If the mains input is stable...

Commissioning steps for Schneider drives Commissioning steps for Schneider drives

1. Type recognition: Recognize whether the type of inverter is common with the type of inverter purchased. 2. Transportation acknowledgement: After opening the package, check whether the inverter is damaged during transportation. 3. Voltage recognition: the power supply voltage on the site should be borne by the inverter.

Schneider inverter external potentiometer connection Schneider inverter external potentiometer connection

The two wires are connected to the resistor, and the other wire is connected to the conditioning terminal. The red thread is attached to the blackhead and inserted in a small hole. Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI. ...

Schneider inverter inverter field interference solution Schneider inverter inverter field interference solution

1. Use software anti-disturbance method In detail, the carrier frequency of the inverter is lowered through the human-machine interface of the inverter to an appropriate scale. If this method does not work, then the following hardware anti-disturbance method can only be adopted. 2. Carry out positive ...

Schneider ATV series inverter used as inverter power supply? Schneider ATV series inverter used as inverter power supply?

Can Schneider ATV series inverter be used as a variable frequency power supply? No, you can't. The inverter is a control device designed according to the characteristics of the communication asynchronous motor, and cannot be used as a variable frequency power supply. The entire circuit of the variable frequency power supply is composed of a ditch ...

Schneider inverter debugging steps and brief description Schneider inverter debugging steps and brief description

Commissioning process of the Schneider 61 series 1. Preparations 1. Measure insulation. Connect the power supply side (R.S.T) and the motor side (U.V.W) of the inverter Disconnect the cable, insulate the cable with a 500 megaohm or 1000 megaohm shake meter, and if it meets the requirements, restore it.

Schneider servo model introduction Schneider servo model introduction

LXM23DU01M3X servo drive 0.1 kW LXM23DU02M3X servo drive 0.2 kW LXM23DU04M3X Servo drive 0.4 kW LXM23DU07M3X Servo drive 0.75 kW LXM23DU10M3X ...

Schneider Electric executive support merger software Saas company Schneider Electric executive support merger software Saas company

MergerWare has raised an undisclosed amount of money ahead of its Series A funding round, an executive told TechCircle. The Company provides software solutions to help integrate mergers and acquisitions-related businesses. The funding came from electrical equipment manufacturer Schneider Electric (Schneider ...

How Schneider contactors work How Schneider contactors work

1. Contactor refers to an electrical appliance that uses a coil to flow through an electric current to generate a magnetic field, so that the contact is closed, and then the load can be controlled. Because it can quickly block the main circuit and frequently connect the equipment with high-current control circuits, it has been widely used in electrical engineering.

Diode selection and substitution method - Schneider Diode selection and substitution method - Schneider

1. Selection of detection diode Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Despite the ...

Inverter control motor speed method - Schneider Inverter control motor speed method - Schneider

1. Why can the rotation speed of the motor be changed freely? Motor rotation speed unit: r/min number of rotations per minute, can also be expressed as rpm. Example: 2-pole motor 50Hz 3000 [r/min] 4-pole motor 50Hz 1500 [r/min] Conclusion:...

Precautions for the use and maintenance of instruments and meters - Schneider Precautions for the use and maintenance of instruments and meters - Schneider

Attention should be paid to the following matters during the use and maintenance of the appearance of the instrument: 1. Don't blindly knock and bump when overhauling, so as not to expand the problem, and the more you repair, the worse it will become. ​ 2. Do not plug and unplug various control boards and plugs with electricity. Due to the power-on ...

Rebecca · Lowell · Edwards Schneider Electric's first Global Head of Communications Rebecca · Lowell · Edwards Schneider Electric's first Global Head of Communications

GENEVA – Rebecca Lowell Edwards, who has been with the International Olympic Committee for the past 18 months·· has joined Schneider Electric as the company's first global communications chief. In the new work that starts today, love ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top