In most cases, in Europe, the thermostat is a necessary accessory for the wall-hung boiler, and the two are delivered to the user at the same time, and most of the thermostats equipped are intelligent thermostats. In China, nearly 95% of the wall-hung boilers that have been installed and are being installed and debugged and ready to be put into use are not equipped with any form of simple or intelligent thermostats. The room heating system is equipped with thermostats, especially intelligent thermostats, which is an extremely prominent and important link in the energy-saving heating comprehensive system.
Convenient: Automatically adjust the wall-hung boiler in advance or delayed every day, eliminating manual operation, which is the most necessary for office families;
Comfort: The room temperature is automatically adjusted in the morning, noon and evening every day, so as to avoid the embarrassment of waiting for the room to heat up and freeze after getting up in the morning and returning home from work;
Gas saving: change the backward extensive water temperature control to advanced and accurate room temperature control, plus the time period to set the room temperature on demand, no need to open day and night gas heating;
Rest assured: when the room temperature is too low, the wall-hung boiler is forced to start, and only a very small amount of gas is needed to safely carry out anti-freezing protection in the room.
Thermostats are widely used in various home appliances, such as refrigerators, water dispensers, water heaters, coffee pots, etc. The quality of the thermostat directly affects the safety, performance and life of the whole machine, and is a very critical component. Among the many technical indicators of thermostats, life is one of the most important technical indicators to measure thermostat products. The standard for household appliances stipulates that the life of the thermostat is at least 10,000 times, and the life of some thermostats in some household appliances, such as refrigerator products, which control the motor-compressor, and some thermostats in the liquid-filled radiator, are required to be at least 100,000 times. The corresponding standard GB14536.10-2008/IEC60730-2-9:2004 for household thermostats has detailed provisions on the life test of thermostats.
|
More on that
|
For some considerations in the RKG thermostat setup
RKC Thermostat Operation Note:
1. Clean the instrument only after the power is off;
2. To remove the stains on the monitor, please use a soft cloth or cotton paper;
3. The display is easy to be scratched, and it is forbidden to use hard objects to operate the panel buttons, otherwise the buttons will be damaged or scratched.
RLC thermostat ...
|
|
RRKC thermostats – how are temperature controllers wired and commissioned?
1. Take out the room temperature controller, and then connect the power supply terminal of the temperature controller to the power supply according to the terminal diagram of the temperature control chart
2. Then take out the temperature sensor that comes with the temperature controller and detect it
3. According to the temperature controller terminal, the temperature sensor is connected to the controller's transmission.
|
|
RKG thermostat – how the temperature controller sets the parameters
1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. The upper limit deviation alarm is set ...
|
|
RHK thermostat – a rapid detection method for common air conditioner thermostats
1. Bellows or diaphragm air conditioner thermostat
1. Fault phenomenon: poor contact or burning, resulting in the circuit can not be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control.
...
|
|
RK Level Gauge - Four common types of faults and solutions for float level gauges
1. The indicated value is large (or out of range).
According to the investigation of our staff, this kind of problem often appears in the atmospheric pressure workshop. When we find that the counterweight of the float in the float level gauge is at a low point, the liquid level must be very high at this time, and the glass plate is inconsistent with the indication of the instrument.
|
|
RRC Thermostat – Instructions for use of smart thermostats
1. Turn on the power of the smart thermostat, and the current temperature is displayed on the display. Because the sensor is not in contact with other devices, but is exposed directly to the air, this is the current temperature: 31 degrees Celsius, which is not too hot.
2. At the bottom right of the display is the "Startup Temperature" setting.
|
|
What should I pay attention to when operating the RKC thermostat?
The instrument can be cleaned only after the power is off;
To remove stains from the monitor, use a soft cloth or cotton paper;
The display is easy to be scratched, and it is forbidden to use hard objects to operate the panel buttons, otherwise the keys will be damaged or scratched.
...
|
|
Introduction to the types of alarms for RRKC thermostats
* Alarm table {ALM1} (standard built-in)
A: Upper limit deviation alarm G: Standby upper and lower limit deviation alarm attached
B: Lower limit deviation alarm H: Upper limit input value alarm
C: Upper and lower limit deviation alarm J: Lower limit input value alarm
D: Alarm in the range K: Attached standby ...
|
|
RHK thermostat - the thermostat shows the reasons for the deviation between the temperature and the actual temperature and the solution
The thermostat shows a nonlinear relationship between the temperature and the actual temperature deviation:
(1) The input type of the thermostat is selected incorrectly;
(2) There is no calibration or calibration error in the analog input;
(3) There is interference in the thermostat;
(4) There is interference with thermocouples;
(5) The use of quality is not ...
|
|
RKC thermostat - introduction of three wiring methods of thermal resistance
1. The three wiring methods of Pt100 RTD are different in principle:
The two-wire system and the three-wire system are measured by the bridge method, and the relationship between the temperature value and the analog output value is given after ***. There is no bridge on the four wires, it is completely just sent with a constant current source, measured by a voltmeter, and the test is given after *** ...
|
|
RHK thermostat – a rapid detection method for common air conditioner thermostats
1. Bellows or diaphragm air conditioner thermostat
Fault Symptom:
Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The leakage of the thermostat in the temperature sensing chamber causes the contact to fail to operate and lose control ...
|
|
RHK thermostat - the use of electronic thermostat and its classification introduction
First, the use of electronic temperature controller
The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, and these resistors have their own advantages and points. Home Air Conditioner ...
|
|
RKC thermostat How to quickly understand the wiring diagram of the thermostat
There are many models of temperature controllers, and the output methods are slightly different, but the wiring principle is the same.
The working principle of the thermostat: the main circuit of the power supply is directly connected to the heating device through the main contact of the AC contactor.
|
|
RLC Thermostat – The reason why the temperature control meter shows HHH
The reasons why the temperature control table shows HHH are as follows:
1. The thermocouple signal line is reversed, or short.
2. If the temperature control meter is in normal use before, it is recommended to check whether the signal line of the thermocouple is broken.
3. The wire inside the thermocouple is broken.
4 ...
|
|
Specifications and models of RLC thermostats
CH102 (48×48×100mm)
CH402 (48×96×100mm)
CH902 (96×96×100mm)
1. RH400 size: 48*96, depth 60, about 250g
1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L
...
|
|
RRC thermostat - how to adjust the smart thermostat
1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET button digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, long press the △ key or ▽ key The data will change rapidly, press the SET key again ...
|
|
Wiring method and control method of RKC thermostat
1. Wiring method
Take CD901 as an example,
L(1) pin to 220 volt live wire,
N(2) pin 220 volt neutral wire,
3,4 pins for the first output,
5,6 pins for the second output,
7, 8, 9 pins are alarm output,
The last three legs are connected to ...
|
|
What are the solutions to the failure of the RRKC thermostat - the sudden thermostat?
1. The cleanliness and finish of the contact surface have a great impact on the working condition of the contact. When the surface of the contact is rough or there is excess material on the contact, it is easy to cause arcing and reduce the life of the contact. Therefore, the parts cleaning process should be improved to eliminate excess materials; Increasing the process of screening excess materials, ...
|
|
RKC Thermostat – What are the common faults of thermostats?
1. There is no manifestation when the power is on. For this kind of problem, first confirm whether the power supply is there and whether the power supply matches the power supply required by the thermostat, and then check whether the wiring is strong. The problem is still there, then it is the problem of the thermostat itself.
2. There is a manifestation, and the manipulation makes mistakes. The first thing to look at this kind of problem is to look at the control ...
|
|
RLC thermostat – the working principle of an electronic temperature controller
Electronic temperature controller, as the name suggests, is a kind of controller that controls the temperature through electronic circuits, it is mainly used for temperature control of electric heating and plumbing, it is easy to learn in the operation method, and the accuracy of control is also very accurate.
|
|