1. For the switching input and output circuits, pay attention to the consistency criterion of maintaining the situation; The positive logic criterion is usually used, that is, when the input and output are live, it is the "ON" state and the data value is "1"; On the other hand, when the input and output are powered off, it is in the "OFF" state and the data value is "0". In this way, it is easy to understand and protect.
2. The switching input and output modules with large loads should be isolated from the site through relays; That is, the field contact should not be directly connected with the input and output module as much as possible.
3. When using the mandatory function provided by the PLC, it should be noted that the situation should be restored after the test; At the same time, you should not force too many points to avoid damaging the module.
|
More on that
|
Causes and solutions of inverter leakage - Xinjie
1. The cause of the leakage problem
Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reason for this problem is explained and stated as follows.
Depend on...
|
|
A brief introduction to some XD series PLCs of Xinjie
XDM Series Sport Control (Control Points: 24/32/48/60)
Support basic motion control instructions, can realize two-axis linkage, interpolation, follow-up and other functions, can achieve 4-axis independent pulse output, up to 10-axis pulse output, together to support almost all of the standard PLC...
|
|
PLC programming algorithm - Xinjie PLC
1. The switching quantity is also called the logical quantity, which means that there are only two values, 0 or 1, ON or OFF. It is the most commonly used control, and it is the advantage of PLC to control it, and it is also the most basic use of PLC.
The intention of switching quantity manipulation is to use the current input combination of the switching quantity with the historical input ...
|
|
False load connection method in the debugging of the inverter - Xinjie
There are many novices who are not familiar with the false load about the maintenance inverter, and the maintenance inverter uses the false load to keep many of their modules, because the maintenance novice generally does not know how to do this, and now the electric light is on to clarify that the module is going to be broken. A dummy load is a load with a resistor of several hundred ohms ( ...
|
|
Common problems and solutions of Xinjie PLC
1. Why can't the PLC communicate with the peripherals?
Communication failures are generally summarized as the following problems:
1. Communication cable: The connection may be incorrect, or the contact is poor, the user can change the communication cable and try again.
2. Communication parameters: PLC communication port and peripheral equipment ...
|
|
Xinjie WIFI communication module WBOX
Product Description:
According to the 2.4GHz Wifi wireless communication module, it has RS232 and RS485 interfaces
Compatible with Xinjie XC2 - XCM series, XD series PLC, MODBUS RTU equipment
The XD-WBOX-ED is connected to the left side of the XD series PLC
Opt IEEE802.11b.g. ...
|
|
The range of use of Xinjie general inverter
A universal inverter is an electronic device used to control the speed of an electric motor, which can change the speed of the motor according to the demand, and then achieve higher output power and power savings. Universal inverters have a wide range of application scales and can be used for various types of electric motors, including communication motors, direct ...
|
|
VFD Configure Braking Resistor step
Confirm the rated power and resistance value of the braking resistor. The rated power of the braking resistor should be determined according to the power and moment of inertia of the motor, and the resistance value should be selected according to the specifications of the VFD.
In the VFD's parameter settings, find the parameters related to the braking resistor, such as the braking resistor selection ...
|
|
Advantages of using motor soft starter - Xinjie
The motor soft starter is a new type of starting equipment designed and produced by using power electronics skills, microprocessing skills and modern control theory.
The motor soft starter can effectively limit the starting current of the AC asynchronous motor when starting, and can be widely used in wind ...
|
|
Attention to the solution of heat dissipation in the application of inverter - Xinjie
Assuming that the inverter has a long service life, heat dissipation must be carefully considered. Because the equipment failure rate of the inverter increases exponentially with the increase of temperature, the service life decreases. If the operating temperature rises by 10 degrees, the service life of the inverter will decrease.
...
|
|
The way the PLC controller works - Xinjie
Although many relays, timers and counters are often used in the ladder diagram programs used by PLCs, PLC does not have these hardware physically, but uses memory and program programming methods to do logic control and editing, and connects external mechanical devices to make physical devices through output components.
|
|
Xinjie released MS6 series B3 motors
Since the advent of the MS6 series B1 and B2 servo motors, they have been widely recognized by customers for their outstanding performance advantages, and their performance in terms of temperature rise, overload ability, overspeed range and protection level is far better than that of MS5 series servo motors.
This MS6 series B3 motor released will ...
|
|
Advantages and opportunities of domestic PLC - Xinjie
At present, in the domestic PLC market, there are many kinds, but there are not many domestic PLC manufacturers with real strength, most of the domestic PLC is not an individual who does not have the qualification of a legal person, or a single-chip microcomputer enthusiast, from the domestic PLC factory to buy the underlying programming code or buy a domestic PLC chip (the domestic P that burns the underlying code...
|
|
The safety standard of the inverter - Xinjie
World electrical safety standards: The requirements are in line with the world's electrical safety standards, such as the CE standard in Europe and the UL standard in the United States. These specifications specify the requirements for electrical safety functions, mechanical safety functions, EMC functions, etc.
Machine...
|
|
The risk cost of using the inverter - Xinjie
When we select the right inverter brand, we need to recognize whether it can help enterprises better manage the risks and costs caused by potential safety, security and downtime accidents.
Safety: Reverse arc drives assist users in meeting stringent reverse arc specifications. These inverters (Variabl ...
|
|
Advantages of Xinjie touch screen and PLC wireless measurement and control network solution
1. Save the transformation cycle, no need for large-scale construction: eliminate the trouble of wiring maintenance, and easily complete the transformation within one day and meet the requirements of communication stability.
2. The device is simple, no programming is required: the wireless communication terminal only needs to ...
|
|
The main role and function of TP touch screen
The primary role of the TP contact screen
Supervision: Reflect the internal bit status of the PLC in various ways such as data, curves, graphics, animations, etc., store the numerical value, and then intuitively reflect the process and direction of the industrial control system.
Exercise...
|
|
Introduction to the configuration method of inverter - Xinjie inverter
1. Acknowledging the characteristics of the load such as load type, speed, and nature;
2. Acknowledging whether it is continuous work, long-term work, short-term work and other work characteristics;
3. Acknowledging the maximum consumption output value and the extra output value;
4. Acknowledging ...
|
|
Small PLC Market Analysis - Xinjie
PLC programmable logic manipulators are the core part of industrial control. According to the number of I/O points of PLC, PLC can be divided into three categories: small PLC, medium and large. It is a digitally operated electronic device designed for industrial production. It uses a programmable memory to store programs that execute user-facing ...
|
|
Xinjie PLC inverter visual system
XC can be divided into multiple sub-series according to the incompatibility of functions, including XC1 (economy), XC2 (foundation), XC3 (standard), XC5 (enhanced) and their corresponding expansion modules, as well as special imitation ontology, activity control models, etc. Powerful function, complete variety, can be full ...
|
|