1. The fastening wiring force should be moderate, avoid sliding the bolts and nuts with excessive force, and replace the bolts and nuts that have been slid in time, and prohibit the operation.

                               Precautions for terminal block wiring - Wiener

2. When tightening or loosening the screws with a screwdriver, it is necessary to force the screwdriver to hold up the screws, and then tighten or loosen them to avoid the screwdriver and the screws slipping, resulting in screw damage that is not easy to disassemble and assemble, especially the common empty opening in the hanging box.

3. If you find bolts and nuts that are difficult to disassemble, do not act recklessly to avoid deformation and more difficult to disassemble, you should give a proper hit, or add screw loosening agent, dilute hydrochloric acid, etc.

4. Do not use vise to tighten or loosen the bolts and nuts to prevent damage, and adjust the opening when using a live wrench to avoid damage and deformation of the bolts and nuts, which is not easy to disassemble and assemble.

5. The same terminal is promised to connect up to two wires of the same type and standard.

6. For terminals that are easy to loose or easy to touch, it is necessary for wire joints to start with "? It is fastened to the terminal block to increase the touch area and avoid loosening.

7. When the wire joints or wire noses are connected to each other, it is forbidden to install non-copper or gaskets with poor conductivity in the middle.

8. When the wire joint is connected, the touch surface is required to be lubricated and there is no oxidation, and when the wiring nose or copper bar is connected, the conductive paste can be changed after the touch surface is cleaned and then fastened.

9. When connecting the temporary wire, half of the terminal head of a single wire is required to be connected to the soft wire, and then it is connected to the empty opening of the lower port; Single-core hard wire should be "? The type is connected to the empty open lower mouth.

10. For the wiring of 30KW and above motors, it is required that the gaskets with poor conductivity should not be crossed between the motor outlet and the cable wires connecting the motors, such as galvanized nuts, flat washers, spring gaskets, etc.

11. When using insulating tape to wrap around cables or other equipment to protect insulation, the insulation layer should be surrounded from one end to the other end by pressing 1/2 share, and at least one back and forth.

More on that
Busway installation method - Wiener Busway installation method - Wiener

1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm; 2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts. 3. In the process of installation construction, priority should be given to the power supply system, ...

Introduction to Laminated Busbar System – Wiener Introduction to Laminated Busbar System – Wiener

In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar. ...

Power system bus wiring features - Wiener Power system bus wiring features - Wiener

1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, small investment, convenient operation and conducive to expansion, but the reliability and flexibility are poor. When there is a fault or maintenance of the bus bar or bus barrier switch, the full power supply of the bus must be disconnected. ...

Rectangular busbar, trough busbar, and tubular busbar analysis Rectangular busbar, trough busbar, and tubular busbar analysis

The rectangular bus has good heat dissipation performance and is easy to fix and connect. But its skin effect is quite large. In order to reduce the skin effect, the cross-sectional area of a single busbar should not exceed 1250 square millimeters. When the working current exceeds the promised current of a single bus, 2 to 4 rectangular buses can be used. Rectangular conductor a ...

Development of the busbar trunk system – Wiener Development of the busbar trunk system – Wiener

(1) Air-type busway Since the mid-50s of the last century, represented by Beijing Baizhifang Airport Electrical Appliance Factory, the conductive row has been supported in the shell with insulating liner and insulated by air medium. The phase-to-phase distance is 50mm. (2) Secret ...

The advantages of busway are used in cable tray installations The advantages of busway are used in cable tray installations

At the time of the cable tray installation, the wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plug-in bus...

Wiener enclosed busbar installation Wiener enclosed busbar installation

Closed busway is a busbar system composed of metal plates (steel plates or aluminum plates) as protective shells, conductive strips, insulating materials and related accessories. It can be made into a piercing closing bus with spaced piercing junction boxes, or a feed-in closing bus without a junction box in the middle. ...

The advantage of closed busbar over open busbar is Wiener The advantage of closed busbar over open busbar is Wiener

1) Closing the bus duct can reduce the grounding fault, prevent the short circuit between the phases, and fundamentally eliminate the grounding fault caused by external moisture, dust and foreign objects, and improve the continuity of generator operation. 2) Eliminate the surrounding ...

Comparison of several insulated tubular busbars Comparison of several insulated tubular busbars

The use of insulated tube bus in China has a history of nearly 20 years, and it has made a historic contribution to reducing the layout space of the distribution bus and improving the reliability of the bus operation. There are many manufacturers who supply this product, and their production processes are uneven, and the differences in processes are mainly reflected in the ...

Features of the use of closed busway - Wiener Features of the use of closed busway - Wiener

Compared with other air-type busway, Wiener closed busway has many similarities in appearance, and its difference lies mainly in the shell, the structure of the closed busway is more distinctive, which also makes its use have certain advantages. As long as it is in contrast ...

How to solve the fault of the busway How to solve the fault of the busway

If there is a problem in the bus duct of the double bus wiring, it is necessary to pay attention to the operation mode of bus maintenance in the process of dealing with the problem, and if necessary, the bus maintenance should be stopped for a short time. After the bus voltage disappears, the dispatcher should immediately swing the switch (including the bus tie switch) that may call, and notify the operation team to ...

Uses and characteristics of busbar systems – Wienal Uses and characteristics of busbar systems – Wienal

The bus system is a system with standardized bus distance, which is used in low-voltage power supply and distribution switchgear and control equipment, so that the bus can play the effect of conducting electricity and supporting electrical components. The system is divided into 40, 60, 100 and 185mm ...

Closed busway essentials – Wiener Closed busway essentials – Wiener

Before the closed busway device, it should be ensured that the electrical shaft, the transformer and distribution room, the decoration project of the place through which the busway passes, and the heating and ventilation project are all completed to ensure that the closed busway is not polluted. The reserved holes and embedded parts of the floor and wall should be embedded and reserved according to the position required by the design. ...

Introduction to the hazards of arc light – Wiener Introduction to the hazards of arc light – Wiener

The arc of the switchgear cable distance problem causes the pressure and temperature in the switchgear to increase quickly, and if not removed in time, it will form a major hazard in the following aspects: (1) The arc temperature is 2 times the appropriate solar temperature, and the large ...

Wiener fixed and busbar mounting Wiener fixed and busbar mounting

Precautions for the device VDE 0660 Specification Section 107 / EN 60947-3 Specification / IEC 60947-3 Specification 3 poles are broken at the same time, double breakpoints. Operator-independent, safe opening/closing, in position ...

Advantages of installing cable trays with busway – Wiener Advantages of installing cable trays with busway – Wiener

When it comes to cable tray installation, wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plug-in bus duct, fireproof bridge is the way it uses plugged in.

Wiener is a common way to wiring busbars Wiener is a common way to wiring busbars

Single bus wiring method: all outgoing wires are connected to the same busbar, which is also the most cost-effective and simplest wiring method Single bus segmentation: The outgoing line is arranged in two parts on different sections of the single busbar, so that a power failure in the meantime does not affect the power supply of the other bus ...

Advantages of cable tray installed in busway Advantages of cable tray installed in busway

At the time of the cable tray installation, the wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plugging ...

The difference between metal busbar and closed busbar - EVOC The difference between metal busbar and closed busbar - EVOC

The nature is different Busbar: It is a common path on which multiple devices are connected in the form of side-by-side branches. Busway: It is a closed metal equipment composed of copper and aluminum busbars. Different uses Mother...

Wiener busbar system PT disconnection treatment Wiener busbar system PT disconnection treatment

The judgment of PT three-phase voltage loss (symmetrical disconnection) is fundamentally the same for each manufacturer, and it is judged according to the three-phase no voltage and the current of the line. The same is true for PT asymmetrical wire breakage. After analyzing the characteristics of PT wire breaking, the specific judgment of PT asymmetric wire breaking of different manufacturers ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top