The advantage of the busway is that its structural design is simple, it is composed of metal plates, which can connect the circuits together, so as to achieve the safe and reliable transmission of electric energy. In addition, its structural design can effectively help reduce the occurrence of short circuits, reduce heat loss, and effectively ensure the reliable operation of the power system. There are also a number of other advantages. It can effectively reduce the noise of current activity, reduce the disturbance of electromagnetic waves, effectively improve electromagnetic compatibility, assist in improving the reliability of the power system, and effectively reduce the energy consumption of the power grid.
In general, the busway is an important part of the power system, which can effectively reduce the energy consumption of the power grid, improve electromagnetic compatibility, and help us transmit electric energy more safely and reliably. It can be said that it is a magical thing in the power system, which provides more bento for our days. It is an indispensable and important part of the modern power system, which can effectively solve the connection problem of the power system. The structure of the bus duct is simple, the ability to resist electromagnetic disturbance is strong, and it is the primary wiring equipment in the large-scale power system. The following is an introduction to the strategy of busway.
When selecting a bus duct, it is necessary to select the appropriate bus duct model according to the actual situation of the power system. There are many types of busway, such as ordinary type, detachable type, quick disassembly type, fixed type, etc. According to the different loads, the low-voltage bus duct and the high-voltage bus duct can be selected, and the standard parameters of the bus duct should be paid attention to when and time of selection, so as to ensure the safety and reliability of the bus duct. Next, it is necessary to pay attention to the insulation of the device to ensure electrical safety. In the process of installation, the spacing between each bus duct should be ensured to ensure safe and reliable operation. Before installing the busway, it should be cleaned first to avoid pollution, oil pollution, etc. that damage the safety performance of the busway. Once the busway has been installed, it is necessary to check them accordingly to ensure that they are in the correct orientation and that there is no damage.
It is to connect the bus duct, and when connecting the bus duct, we should pay attention to the insulation to ensure the safety of the operation. When connecting the bus duct, it is also necessary to pay attention to the wiring method of the bus duct, and ensure that the conductor of the bus duct is outstanding to ensure the normal activity of the current. When connecting the bus duct, it is also necessary to pay attention to the current to ensure that the bus duct can meet the needs of the power system.
The above is the strategy about the bus duct, the bus duct is an important part of the modern power system, in the use of the bus duct to pay attention to safety, in order to ensure the normal operation of the power system.
|
More on that
|
Knowledge points of Wiener busway
Busway was born in the United States, first put into practical use in Japan, and then spread all over the mountains and regions in prosperous countries and regions. So what is a busway? Busway is a high-current trunk tappable power supply system, usually made of a metal housing (iron or aluminum).
|
|
The way in which the Wiener high-voltage busway is selected
In the selection, the following elements should be fully considered: fire protection specifications, insulation layer to flame retardant, good temperature resistance, high temperature is not easy to release harmful gases, structure type to avoid chimney effect, should give priority to the use of aggregate insulation layer bus duct, such as the use of air insulation type, it must be in the electric ...
|
|
Wiener bus differential protection switching operation
1. Whether the scale of bus differential maintenance is determined, and whether the maintenance goal is unchanged
Generally, differential maintenance includes bus differential maintenance, transformer differential maintenance, generator differential maintenance and line differential maintenance. The basic principle of achieving differential maintenance is common, i.e. on all sides or on each side...
|
|
Introduction to busbars, busway, and busbridges - Wiener
generatrix
In the field of electricity, the busbar can also be called the busbar, busbar, etc., which mostly refers to the busbar or power supply trunk in the high and low voltage cabinet, which is used to connect multiple electrical lines. The system will install various interface cards through the bus, and transmit various data to the devices connected to the interface cards.
|
|
Analysis of the product characteristics of Wiener busway
Since the busway is made of copper bars or aluminum as conductors, it has a large current capacity and good electrical and mechanical properties. In addition, it is made of a metal trough as the shell, so it is non-flammable, safe and reliable, and has a long service life. Compared with traditional power distribution or ...
|
|
Dense busbar installation – Wiener
1. Requirements for civil engineering before installation
1) The foundation, structure, reserved holes and embedded parts all meet the design requirements of electrical equipment.
2) After the construction of the roof and floor slab is completed, there shall be no leakage.
3) After the indoor ground construction is completed, mark the ground leveling line on the well wall.
...
|
|
Ship unloader distribution cabinet convergence mode - Wiener
In the hardware layout planning of the ship unloader distribution cabinet, in order to omit the wiring slot pawn, save time and effort in wiring, prevent wiring errors, and make the distribution cabinet beautiful and useful, the circuit breaker inlet end in the distribution cabinet will use the confluence method. Here are a few commonly used ways to combine the flow with Siemens circuit breakers.
|
|
Advantages of a shared DC bus system – Wienal
The shared DC bus system is the future development direction in the application of multi-drive motors, which makes reasonable use of the regenerative energy of the system together with better dynamic and static functions and speed regulation accuracy, eliminating a lot of braking units and braking resistors, and the energy efficiency ratio of the system has been greatly improved.
|
|
Wiener bus adapters are suitable for use with Siemens 3VA1 and 3VA2 circuit breakers
For the use of Siemens' new 3VA1 series circuit breakers in the 30Compact system with currents up to 160A, Wiener has developed an EQUES® bus adapter.
A spring-loaded base and high-performance internal power rails ensure safe connection to the circuit breaker.
advantage
...
|
|
Busbar system in detail – Vernal
1. In the 60mm bus system, the square fuse type blocking switch can be directly hooked.
2. The 60mm bus system refers to the three-wire or four-wire bus spacing of 60mm.
3. Strip NH-fuse type load barrier switch with scale 00 ...
|
|
What is the role of the busbar in the distribution box
Busbar refers to a product made of copper and aluminum materials with high conductivity to transmit electrical energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transport electrical energy. In the power system, the busbar in the distribution box connects the various current-carrying branch circuits in the distribution unit, ...
|
|
Specific optimization application of ship unloader bus system - Wiener
1. Bus system 1
The bus adapter used in bus system 1 is more miscellaneous, and -Q1 selects a bus type blocking switch that can be directly attached to the bus; -Q11 is a 3VL2 switch, select an appropriate universal adapter to hook up to the bus; The 3-pole switch-Q12——-Q15 is less than 63A, but ...
|
|
The essence of Wiener busbar technology
1. Closed busbar hooking technology
Circuit breakers and contactors can be hooked on the bus through the bus adapter, and fuse switches and other products are directly attached to the bus, so the bus bar plays a two-layer effect of conductive and fixed rotation.
|
|
The difference between metal busbar and closed busbar - EVOC
The nature is different
Busbar: It is a common path on which multiple devices are connected in the form of side-by-side branches.
Busway: It is a closed metal equipment composed of copper and aluminum busbars.
Different uses
Mother...
|
|
What are the characteristics of the bus wiring method of the power system?
(1) Single bus wiring. Single bus wiring has the advantages of simplicity and clarity, less equipment, less investment, and convenient operation and expansion, but its reliability and activity are poor. When the bus or bus separator is faulty or overhauled, all power to the bus must be disconnected.
...
|
|
Differences and differences between busway and other busbars
The busbar and busway are actually one open and one closed, and the other is not closed. The closed busway is referred to as the busway, that is, the busway is sealed
The closure of the busbar, the closure of the busbar and the busway all refer to the same east...
|
|
Performance characteristics of low-voltage busbar system - Wienal
Introduction to the performance of low-voltage bus system:
1. The bus bar is not perforated, and is connected with the cable and copper bar through the connection clip or terminal
2. Switches, contactors and other electrical components can be directly hung on the bus through adapters
3. Save ...
|
|
A new product has been added to the world of CrossBoard® systems
A new addition to the world of CrossBoard® systems: the MOTUS® hybrid motor starter with IO-Link interface is a new networking feature in the MOTUS® IO-Link family that enables continuous communication between the control and device levels. Control the delivery of instructions, control the parameters ...
|
|
Precautions for installation of Wiener busway
1. Before the bus duct installation, it should be ensured that the electrical shaft, substation and distribution room, the decoration project of the place through which the bus duct passes, and the heating and ventilation project are all completed to ensure that the bus duct is not polluted. The reserved holes and embedded parts of the floor and wall should be embedded and reserved according to the position required by the design. The functions of the busway are single ...
|
|
Wiener busway plug-in box wiring method
The bus duct bracket has to be firmly installed, and the bus duct should be correctly placed according to the segment sequence number, phase sequence, number, direction and device mark, and when the sections are connected, the adjacent section of the bus duct should be aligned, and the conductor and shell of the bus duct should not accept mechanical stress after the connection.
...
|
|