Steps for using Pilz safety relays

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

Pilz safety relays consist of several relays and circuits to compensate for each other's abnormal defects and achieve the full functionality of a relay with low misoperation or even correct relays. The lower the fault value and fault, the higher the safety factor. In order to prevent unavoidable misoperation or natural wear and tear of the machine, what other aspects should be prevented from misoperation so that it can be used correctly? Let Bianshaw take you through safety relays from Pilz.
Steps for using Pilz safety relays
  First of all, the correct operation steps of the Pilz safety relay are demonstrated:

Measure the contact resistance.

Using the resistance file in the table, measure the moving point resistance and the normally closed contact, the resistance value of which should be 0, (in this way, the contact resistance value can be measured within 100 milliohms); The value of resistance between the normally open contact and the moving point will be unlimited. This makes it possible to distinguish which one is NO and the other is NC.

Measure the coil resistance.

The resistance value of the power relay coil can be measured in the 10Ω position of Table R× to determine whether the coil is open.

Measure adsorption current and adsorption voltage.

Find an instrument that can regulate the regulated current and power supply, input a set of voltages to the power relay, and connect an ammeter in series in the power supply circuit for monitoring. Slowly increase the mains voltage. When the sound absorption of the power relay is heard, the sound absorption current and sound absorption voltage are recorded. To make the recording more accurate, you can try a few times to get an average.

Measure the release current and release voltage.

Also like the connection test mentioned above, when the power relay is engaged, and then gradually reduce the power supply voltage, when you hear the power relay release sound again, write down the current and voltage at this time, you can also try several times to achieve the average release current and release voltage.

More on that
Pilz launches the maintenance system "Key in Pocket" Pilz launches the maintenance system "Key in Pocket"

The new maintenance system "key in pocket" from Pilz prevents the risk of unauthorised machine restarts and increases the safety of maintenance work. Digital maintenance assurance is based on the access authorization system PITreader, which ensures the safety of machinery and industrial information.

Peel magnetic relays – what are the ways in which the contacts of relays are used? Peel magnetic relays – what are the ways in which the contacts of relays are used?

There are 3 basic forms of relay contacts: (1) The two contacts are disconnected when the dynamic type (normally open, H-type) coil is not energized, and the two contacts are closed after the energizing is applied. It is represented by the pinyin prefix "H" of the word "合". (2) Dynamic breaking type (normally closed, D-type) coil is not energized when the two contacts ...

Pilz: The best helper for safety control systems Pilz: The best helper for safety control systems

The safety control system generates a large amount of data at all times while ensuring the safety functions of its equipment. For example, when the E-STOP button is pressed, when someone opens a certain safety door, who switches the machine to service mode when, etc. This data is important for device managers ...

Pilz myPNOZ is even better suited to two-handed buttons Pilz myPNOZ is even better suited to two-handed buttons

The two-handed button is a commonly used safety start device, which is commonly used in punches, presses, cutting machines and other equipment; The purpose is to force the operator to leave the danger zone with his hands when driving the machine, so as not to come into contact with dangerous moving parts and cause safety accidents.   The "standard" of two-handed control says ...

Pilz: New rope pull switch - Mini model is more economical Pilz: New rope pull switch - Mini model is more economical

Whether on the assembly line or on the machine, the safety rope pull switch is a proven and reliable solution for triggering an emergency stop function from any point on the pull rope to shut down dangerous work processes. Pilz's rope pull switch PSENrope is available in rope lengths up to ...

Pilz at the Hannover Messe 2019 Pilz at the Hannover Messe 2019

Adhering to the motto "Weautomate.Safely." From April 1 to 5, 2019, Pilz will once again present innovative automation solutions at the Hannover Messe in Hall 9, Stand D17. As a safe automation ...

Peel magnetic relay - fault judgment and treatment method of safety relay Peel magnetic relay - fault judgment and treatment method of safety relay

1. Determine whether the safety relay itself is faulty: 1. Separate from the three circuits of short-circuit S10/S12, S11/S12, S21/S22. 2. Turn on the 24V power supply (A1 is positive, A2 is negative), and the Power light should be on at this moment; 3. Reset the S33/S34 terminals, and the K1 and K2 lamps ...

Pilz presents a new product: Safe Protective Area Monitoring is also available for robotic applications Pilz presents a new product: Safe Protective Area Monitoring is also available for robotic applications

For the monitoring of safe protected areas under harsh conditions, such as dust, dirt, rain, light, sparks or shocks, the safety radar sensor PSENradar in combination with the configurable small controller PNOZmulti 2 offers the best solution: in addition to outdoor applications as well as woodworking and ...

Pilz safety switches – how to install safety switches Pilz safety switches – how to install safety switches

1) The installation of the switch panel should be after the installation of the lamp, and the switch must be connected in series on the live line; Application of sealed or protected sockets in wet locations; The allowable deviation of the verticality of the panel is not more than 1mm; The gap between the panels installed in rows should not be greater than 1mm. 2) Where the socket must be facing the switch panel ...

SIX POINTS FOR SAFETY RELAY REPAIR IN PILZ SIX POINTS FOR SAFETY RELAY REPAIR IN PILZ

PILZ PILZ SAFETY RELAYS ARE THE MAIN COMPONENTS FOR CONTROL CIRCUITS AND MONITORING AND PROTECTION SYSTEMS FOR ELECTRIC LOCOMOTIVES. WHEN THE ELECTRIC LOCOMOTIVE IS RUNNING, WHEN THE MOTORS, ELECTRICAL APPLIANCES OR CONNECTION LINES IN THE MAIN CIRCUIT AND AUXILIARY CIRCUIT FAIL, THE FAULT CAN BE REPLACED BY THE PILZ SAFETY RELAY OF THE CORRESPONDING MONITORING AND PROTECTION SYSTEM.

Pilz: Cleared! The risks of the canning line are "gone" Pilz: Cleared! The risks of the canning line are "gone"

Today we share with you the case of ACMI S.p.A., an Italy company dedicated to the production of high-end filling and packaging lines, to see how they do the safety protection of canning lines.   Let's start with their process...... This mineral water filling ...

Pierz switches – what are the properties of safety switches? Pierz switches – what are the properties of safety switches?

The safety switch prevents personnel from entering the hazardous area until all safety conditions have been met Provide bolt switches, safety magnetic switches, safety door lock switches, safety rope pull switches, emergency stop buttons, twisted chain interlocking switches, safety enable switches, safety limit switches, explosion-proof open...

Pilz: Configurable safety relays with reliable delivery times Pilz: Configurable safety relays with reliable delivery times

Have you encountered any of the pain points of these safety relay applications? Since the invention of the first emergency stop safety relay by Pilz in 1987, after twenty or thirty years of development, the current safety relay market can be described as a hundred flowers blooming and a hundred schools of thought contending. Although, the currently selectable security relay ...

Pilmagnetic switches – what are the properties of safety switches? Pilmagnetic switches – what are the properties of safety switches?

The safety switch prevents personnel from entering the hazardous area until all safety conditions have been met Provide bolt switches, safety magnetic switches, safety door lock switches, safety rope pull switches, emergency stop buttons, twisted chain interlocking switches, safety enable switches, safety limit switches, explosion-proof open...

Peel magnetic relays – features of relay modules Peel magnetic relays – features of relay modules

  1. The same module can be triggered by high or low level through different wiring, and the trigger current is not less than 1mA, and the output capacity of the IO port of some 51 single-chip microcomputers is weak, and the circuit of pulling up or increasing the driving capacity is required (the default is low level triggering); 2. Advantages of low-level drive, ...

Pierz supports ACMI S.p.A.'s packaging process Pierz supports ACMI S.p.A.'s packaging process

ACMI S.p.A. is an Italy company specializing in high-tech bottling and packaging lines. Based in Fornovo Taro, in the province of Parma, Italy, the company initially produced palletizers and depalletizers for the food and beverage industry, and later specialized in all packaging processes. For...

Peel magnetic relays – Precautions for the selection of relay modules Peel magnetic relays – Precautions for the selection of relay modules

1. Whether the control voltage of the relay module is consistent with the system voltage. 2. It is still possible to use high level and low level for the level control mode of the relay module. 3. Depending on the requirements, choose whether you need a fully isolated relay module. 4. Safety: Relay ...

How Pilz replaces the safety switch How Pilz replaces the safety switch

1. First, unscrew out the fixing screws of fixing the noodle frame and the water baffle plate according to the above steps; 2. Unscrew out the two screws that fix the safety switch, and pull out the two lead pins connecting the safety switch; 3. Replace the new safety switch and assemble it according to the original steps. Electrical safety switch ...

Pilz: New system version PSS 4000 1.24 Pilz: New system version PSS 4000 1.24

The automation system PSS 4000 offers new features in the new version 1.24. Here's what you need to know:   New data types FIXED and LFIXED The data types FIXED (a fixed digit with 6 decimal places) and LFIXED (a fixed number with 11 decimal places) are now ...

Peel magnetic relay - introduction to the characteristics of high and low voltage relays Peel magnetic relay - introduction to the characteristics of high and low voltage relays

1. High-precision detection: high and low voltage relays can detect high and low voltage signals with high precision, and realize accurate monitoring and control of electrical equipment. 2. Large capacitance switch: High and low voltage relays have good durability and stability when switching high capacitance loads. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383