1) The installation of the switch panel should be after the installation of the lamp, and the switch must be connected in series on the live line; Application of sealed or protected sockets in wet locations; The allowable deviation of the verticality of the panel is not more than 1mm; The gap between the panels installed in rows should not be greater than 1mm.

2) The socket must be facing the switch panel direction left to the zero wire, the right to the live wire, the upper end of the three-hole grounding wire, and the box is not allowed to have exposed copper wires, three-phase sockets, and protective wires to the upper end.

3) The switch panel should be easy to use after installation. The same plane switch in the same room must be arranged on the same horizontal line and in the order most commonly used.

4) The wire behind the switch panel socket should be straightened out and placed in the bottom box in a wavy shape.

5) The wiring on the switch panel adopts the insertion crimping method, the wire end is stripped of the 10mm insulation layer, and the terminal hole is inserted and pressed with a bolt, if the terminal hole is large or the bolt is slightly shorter, the wire can not be compressed, the wire head can be stripped off and folded into a double wire insertion.

6) The switch panel should be installed in the live wire. When there are multiple switches on a panel, each switch should be wired separately, the wires on each switch should be threaded separately, and several switches should have several inlet pipes connected to the junction box. Turn off the light when you pull the switch up. When the rocker switch is installed, there is a red dot facing up, be careful not to install it in reverse, and press the lower half of the rocker to open.

7) Multiple sockets on a switch panel, some of which have been wired with edge pieces; Some sockets are split and need to be connected in parallel with a short wire. The live wire, the neutral wire and the ground wire in the socket should be connected according to the specified position and cannot be connected wrongly.

When installing the switch panel, press the connected wire and the wire connector in the junction box in the box, buckle the panel on the junction box, and fix the panel on the box with screws. When fixing, pay attention to the panel should be flat. It should not be skewed, and it should be tightly buckled on the wall, and there should be no gaps. After fixing the lower panel with screws, cover the decorative surface.
Pilz safety switches – how to install safety switches


More on that
Pilz Safety Burner Management System Pilz Safety Burner Management System

An autonomously running burner management system has a complex structure and must comply with many international standards. Due to the high level of danger, strict safety regulations need to be applied to avoid the presence of unburned fuel in the combustion chamber. Pilz has a safe burner management system specifically tailored to these requirements. ...

Peel magnetic relays – the characteristics and working principle of relays Peel magnetic relays – the characteristics and working principle of relays

When the input quantity (such as voltage, current, temperature, etc.) reaches the specified value, the electrical appliances that make the output circuit to be controlled on or off can be divided into two categories: electrical quantity (such as current, voltage, frequency, power, etc.) relays and non-electric (such as temperature, pressure, speed, etc.) relays.

Pilz – an example of safety radar in the food industry Pilz – an example of safety radar in the food industry

The safety radar system PSENradar is a safe area protection monitoring device based on FMCW radar technology launched by Pilz, which is different from traditional area protection monitoring sensors, PSENradar is not easily affected by the external environment and is suitable for safe area protection monitoring under harsh conditions. ...

Pilz was rated as an advanced unit of the National Printing Machinery Standardization Annual Conference Pilz was rated as an advanced unit of the National Printing Machinery Standardization Annual Conference

On March 1, 2023, the National Printing Machinery Standardization Annual Conference and the First National Coating Machine Standardization Annual Conference were held in Yiwu, Zhejiang. The meeting was guided by the Standardization Administration of the People's Republic of China, the China Machinery Industry Federation, and the Yiwu Municipal People's Government.

Peel magnetic relay - the selection principle of electromagnetic relays Peel magnetic relay - the selection principle of electromagnetic relays

1. Selection of relay coil application power supply Under normal circumstances, most of the relays of direct current are selected in the circuit design, and the types of power supplies used in relays can also be considered according to the characteristics of the control circuit. Secondly, it is necessary to think about the power consumed by the relay, and assume that the relay coil is supplied ...

Pilz: New rope pull switch - Mini model is more economical Pilz: New rope pull switch - Mini model is more economical

Whether on the assembly line or on the machine, the safety rope pull switch is a proven and reliable solution for triggering an emergency stop function from any point on the pull rope to shut down dangerous work processes. Pilz's rope pull switch PSENrope is available in rope lengths up to ...

Pilz: Cleared! The risks of the canning line are "gone" Pilz: Cleared! The risks of the canning line are "gone"

Today we share with you the case of ACMI S.p.A., an Italy company dedicated to the production of high-end filling and packaging lines, to see how they do the safety protection of canning lines.   Let's start with their process...... This mineral water filling ...

Peel magnetic relays - the principle of selection of thermal relays Peel magnetic relays - the principle of selection of thermal relays

1. The relationship between the specifications of the relay and the installation location For different star/triangle control positions, the specifications of the selected thermal relays are also different. As shown in Figure 1, the current setting value of the selected thermal relay is equal to the rated current value of the protected motor. In Fig. 2, the selected thermal relay ...

Pilz: The path of innovation that began with the "mouse connection". Pilz: The path of innovation that began with the "mouse connection".

The debut of "Mouse Wire" in the world of automation dates back to 2002 at the SPS trade fair in Nuremberg, where Pilz presented users for the first time with a configurable small safety controller: no need to know a "higher-level" programming language, thanks to the ease of operation, the graphical ...

Pilz: Three levels of security validation, tailored to the user Pilz: Three levels of security validation, tailored to the user

Pilz's safety validation services for plants and machines can now be customised to suit your needs, choosing between three different validation levels. This guarantees an efficient service tailored to individual requirements, allowing plants and machines to be designed in accordance with standards and with maximum safety. In the wind ...

Pilz: Mechatronics methods for automation Pilz: Mechatronics methods for automation

Smart factories, Industry 4.0 and autonomous production – the mechanical engineering department is now looking forward to a bright future. The pace of innovation and ever-shortening development moments are playing an increasingly important role in the global race. To streamline the engineering process and add reusability to individual components, the regulations ...

Peel magnetic relays - what are the connection methods of relays? Peel magnetic relays - what are the connection methods of relays?

1. 3-pin relay wiring The common 3-pin relay is the car horn relay. No. 1 is the contact terminal, which connects the load; No. 2 is the common terminal between the contact and the coil, which is connected to the power supply; No. 3 is the coil terminal, which connects the button switch (such as the horn on the steering wheel).

Piermagnetic switches – an introduction to the functions of safety switches Piermagnetic switches – an introduction to the functions of safety switches

1. When the load exceeds the action current, the circuit will be automatically cut off; 2. After the circuit is automatically cut off, the panel indicator light is on, which is convenient for the judgment of the fault part; 3. After troubleshooting, press the red button at the bottom of the panel to restore the normal power supply; 4. For other reasons, the shell ...

Peel Magnetic Relays – How to Choose a Solid State Relay Peel Magnetic Relays – How to Choose a Solid State Relay

The naming of solid state relay models has not been unified, and the following conditions should be considered when selecting the manufacturer's manual. (1) Rated input voltage Refers to the maximum allowable effective voltage of a steady-state resistive load that can be withstood under a given condition. When used for inductive loads ...

Peel magnetic relays – what is the difference between a relay and a contactor Peel magnetic relays – what is the difference between a relay and a contactor

1. The effect is not the same: The primary effect of the relay is: signal detection, transmission, conversion or disposal, the circuit current it is on and off is generally small, and it is generally used in the control circuit to control weak signals. The primary effect of the contactor is to turn on or off the main circuit. Host...

Peel magnetic relay - the wiring method of PLC and relay Peel magnetic relay - the wiring method of PLC and relay

1. Y0 is connected to one end of the coil A1 of KA1; 2. The other end of KA1, A2, is connected to 24V; 3. Y1 is connected to A1 at one end of the coil of KA2; 4. The other end of KA2 A2 is connected to 24V; 5. COM terminated to 24V. ...

Pilz: It's easy to build your own customised safety relay Pilz: It's easy to build your own customised safety relay

The myPNOZ Creator online tool, the configurator for the modular configurable safety relay myPNOZ, can be used via a PC with an Internet connection and no need for local installation in advance. Find the entrance to myPNOZ Creator on this page and start an extraordinary experience. ...

Peel magnetic relay – the role of intermediate relays Peel magnetic relay – the role of intermediate relays

1. Replace small contactors: the contacts of the central relay have a certain ability to carry load, and when the load capacity is relatively small, it can be used to replace the use of small contactors, such as electric roller shutters and the control of some small household appliances. This not only serves the purpose of control, but also saves space, ...

Top 5 reasons to choose myPNOZ from Pilz Top 5 reasons to choose myPNOZ from Pilz

Pilz's modular safety relay myPNOZ has received a lot of attention and acceptance since its introduction. It has been nominated for the Hermes Award, the Germany Innovation Award (GIA) and the Red Dot Design Award. This safety app, which can be customized and mass-produced according to user requirements, can be customized according to user requirements.

Pilz: The first products with IO-Link Safety will soon be available on the market Pilz: The first products with IO-Link Safety will soon be available on the market

IO-Link is an open sensor communication protocol that represents a powerful and standardized (IEC 61131-9) connection technology in the field of point-to-point communication and is fieldbus and system independent. The communication protocol will also be used for functionally safe data exchange in the near future. The advantages of IO-Link are ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top