|
For the 20th year in a row, SICK Germany has been on the list of "Best Employers in Germany".
SICK Germany has been ranked 2nd in the list of "Best Employers in Germany 2022"! For 20 years in a row, SICK has been on the list of "Best Employers in Germany"! The list is published by the Great Place to Work Institute®, the world's leading ...
|
|
SICK brought new products to the Industry Fair
The 17th China International Industry Fair (IAS2015) was held in the National Convention and Exhibition Center (Shanghai) from November 3 to 7, 2015.
|
|
Sick OD2000 laser displacement sensor was launched
The OD2000 is an excellent multi-range sensor with a laser displacement sensor measuring within 1,200 mm with high accuracy. Technology based on the principle of laser triangulation, as well as the versatility of the measuring range, make it suitable for many different industry applications.
OD2000 multi-range not only solves the problem of electric ...
|
|
Sick Sensors – An introduction to the photoelectric effect of photoelectric sensors
It is a physical phenomenon in which light irradiates certain substances and changes the conductive properties of the substance, which can be divided into three categories: external photoelectric effect, internal photoelectric effect and photogenerated volt effect. The external photoelectric effect refers to the physical emission of electrons from the surface of an object under the action of light.
|
|
Sick sensors – the working methods and characteristics of fork photoelectric sensors and their differences
How fork photoelectric sensors work:
Placing an optical transmitter and a receiver facing each other on either side of a slot is a fork photoelectric. The luminaire emits infrared or visible light, and the light receiver receives the light in an unobstructed condition. But when the detected object passes through the trough ...
|
|
How to adjust the SICK UM18-51112 sensor
Preparation tools: calibrator to change the distance of the ultrasonic sensor, special regulator and special power supply.
Disconnect the power supply: Disconnect the ultrasonic sensor from the controller and prepare it for commissioning.
Commissioning time: The commissioning time can be adjusted to any time to meet the needs of personalization.
|
|
Sick Sensors – Applications of Photoelectric Sensors
1. Application of photoelectric sensor in high-voltage and high-current testing
In recent years, the use of optical equipment for high-voltage and high-current measurement has developed rapidly in the power system, and many new photoelectric sensor systems have been put into on-site operation, bringing many convenient measures for the monitoring of high-voltage and high-current.
|
|
Sick Sensor - Introduction to the 7 performance indicators of the sensor
1. Linearity: refers to the degree to which the actual relationship curve between the output and input of the sensor deviates from the fitting straight line. Defined as the ratio of the maximum deviation between the actual characteristic curve and the fitted line over the full scale range to the full-scale output.
2. Sensitivity: Sensitivity is the sensor ...
|
|
Sick released a new product, the safety camera safeVisionary2
With the practical application and demand of security protection, the existing 2D protection equipment has gradually been unable to meet the customer's requirements for safety, and the demand for 3D safety equipment is getting higher and higher.
Today we are launching a new product from SICK---safeVisionary2.
|
|
What are the relevant applications for Sick sensors – ultrasonic sensors?
Main applications:
Ultrasonic sensing technology is used in different aspects of production practice, and medical application is one of its most important applications. The application of ultrasound in medicine is mainly to diagnose diseases, and it has become a clinical...
|
|
Sick Sensor - Introduction to photodiodes for photoelectric sensors
1. Photodiode
Photodiodes are generally in reverse operation in circuits
Dark current, photocurrent (the stronger the light, the photocurrent?) )
2. Phototransistor
There is no lead-out at the base, and the collector is positive with respect to the emitter
When the light shines on ...
|
|
Sick Sensors – A detailed introduction to the principles of the five common pressure sensors
1. Piezoelectric pressure sensor
Based on the piezoelectric effect, electrical components and other machinery are used to convert the pressure to be measured into electricity, and then perform related measurement work. Piezoelectric sensors can only be used for dynamic measurements. Host...
|
|
Sick | Cameras from RIBE Technik are used to monitor the assembly facility
Quality assurance through programmable imaging: RIBE Technik from Schwabach has developed an innovative bumper assembly system that includes an inspection system.
Machine vision from SICK enables the identification of individual components and the monitoring of each operating process as a special system concept ...
|
|
Sick sensors – features of photoelectric sensors
1. Long detection distance
If the detection distance of 10 m or more is retained in the through-beam type, it is possible to achieve detection that is not possible with other detection methods (magnetic, ultrasonic, etc.).
2. There are few restrictions on the detected objects
Due to the detection of shading and reflection caused by the detection of objects ...
|
|
Parameter settings for the Sigg distance sensor
1. Set to "Surface" to measure the distance from the first surface within the sensor's detection range. This setting is available for all sensor heads.
2. Set to Glass Thickness to measure the distance from the front to the back of a transparent object, such as glass. This means that it has been measured with the sensing ...
|
|
Introduction to the characteristics of the Sick sensor - laser distance sensor
1. Wide measurement range and fast response;
2. Reflector is not required for long-distance measurement;
3. High measurement accuracy and large range;
4.905 nm safety laser is not harmful to human eyes;
5. Small size, easy to install and debug;
6. On-line continuous measurement to reach unmanned ...
|
|
Sick sensor - the detection procedure of the sensor, the precautions in the detection process
The detection procedure of the sensor
1. Symptom Judgment: Infer the location where the malfunction may occur.
2. Decoder detection: Confirm whether the suspected sensor has a fault code in the decoder, and strengthen the judgment in the data stream.
3. Inspection around the sensor: In case of ...
|
|
Sick Sensors – Applications for thermistor sensors
1. Thermistor sensor temperature measurement
Thermistor sensors used to measure temperature are generally simple in structure and inexpensive. Thermistors without an outer protective layer can only be used in dry places; Hermetically sealed thermistors are not afraid of moisture erosion and can be used in harsh rings.
|
|
Adjustment method of the Sick WFS3-40N415 sensor
(1) Automatic calibration: When the workpiece enters the sensitive area of the probe, hold down the "SET" button for 3 seconds, and the sensitivity value will be set and displayed in green.
(2) Two-point calibration: When the workpiece does not enter the sensitive area, press and hold the "SET" button for three seconds.
|
|
Sick Sensors - Analysis of common fault codes for fiber optic sensors
1. Alarm code E401
E401 is one of the common fault codes of fiber optic sensors, which indicates that the fiber optic sensor has detected that the fiber is cracked or bent. This problem can usually be dealt with by replacing the fiber or adjusting the fiber installation orientation.
2. Alarm code E402
...
|