Tianyi button signal light - how to choose and use the button indicator light Tianyi button signal light - how to choose and use the button indicator light

How to use the indicator color correctly? 1. The indicator light (also known as the signal light) is mainly used to attract the attention of the operator or instruct the operator to carry out a certain operation in the way of bright indication, and as an indication that a certain state or instruction is being executed or has been executed. 2. General ...

Tianyi switch - the operation precautions of the disconnector switch Tianyi switch - the operation precautions of the disconnector switch

(1) Before operation, check that the circuit breaker (switch) is in the opening position accordingly to prevent the isolation switch from being pulled and closed with load. (2) There is a locking device to prevent misoperation between the knife switch, the grounding knife switch and the switch, and the reverse operation must be carried out in order. If it is locked and cannot be operated, ...

Tianyi switch - introduction to the type of disconnector switch Tianyi switch - introduction to the type of disconnector switch

According to the different ways in which it is installed It can be divided into outdoor disconnector and indoor high-voltage disconnector. Outdoor disconnector refers to the disconnector that can withstand wind, rain, snow, filth, condensation, ice and heavy frost, etc., and is suitable for installation on terraces. According to the different structures of its insulating pillars ...

Tianyi switch - the difference between disconnector and circuit breaker Tianyi switch - the difference between disconnector and circuit breaker

1. The circuit breaker is equipped with an arc extinguishing device, so the circuit breaker can be operated with load, but it cannot operate the current of the load. The disconnector does not have an arc extinguishing device, and it can operate places where the load current is less than 5A, but it is generally not suitable for operation with load. 2. And the circuit breaker ...

Tianyi switch - the allowable operating range of the disconnector Tianyi switch - the allowable operating range of the disconnector

1. Pull together the voltage transformer and lightning arrester under normal conditions. 2. Pull together the 220kV no-load bus. 3. The neutral point of the transformer when there is no ground fault in the latching grid. 4. Pull the bypass current that is closed by a switch or an isolated switch. 5. Outdoor vertical splitting triple isolation ...

Tianyi switch - the selection of disconnector switches Tianyi switch - the selection of disconnector switches

Rated voltage: The rated voltage of the disconnector (KV) = the nominal voltage of the circuit * 1.2/1.1 times. Rated current: The standard value of rated current should be greater than 150% of the maximum load current. Rated Thermal Stability Current: Select a rated ...

Tianyi switch - the operation sequence of the disconnector switch Tianyi switch - the operation sequence of the disconnector switch

(1) First of all, when operating the isolation switch, you should first check that the circuit breaker of the corresponding circuit is indeed in the disconnected position to prevent the load from pulling and closing the isolation switch. (2) When the line is stopped and the power is transmitted, the isolation switch must be pulled and closed in order. During the power failure operation, the circuit breaker must be pulled first, and then ...

Tianyi switch - maintenance of disconnector switch Tianyi switch - maintenance of disconnector switch

1) Clean the dust on the surface of the porcelain, check whether the surface of the porcelain is glazed or damaged, whether there are cracks and flashover marks, and whether the iron and porcelain joints of the insulator are firm. If the damage is severe, it should be replaced; 2) Wipe the oil stains on the blades, contacts or fingers with gasoline and check the contact ...

What are the common problems of Tianyi switch - disconnector? What are the common problems of Tianyi switch - disconnector?

1. What are the common faults? Answer: The common faults of the disconnector are: (1) The contact part is overheated. (2) Porcelain insulation damage and flashover discharge. (3) Refuse to pull and close. (4) Wrong pulling and closing. 2. The overheating of the contact part of the disconnector during operation is caused by ...

What requirements should be met by Tianyi switch - disconnector? What requirements should be met by Tianyi switch - disconnector?

(1) The disconnector should have an obvious disconnection point, which is easy to identify whether the electrical appliance is disconnected from the power grid. (2) There should be reliable insulation between the disconnect points of the disconnector, that is, there should be enough distance between the disconnect points of the disconnector to ensure that it can work reliably under harsh climatic conditions, and ...

Tianyi switch - the use conditions and applicable places of low-voltage isolation switch Tianyi switch - the use conditions and applicable places of low-voltage isolation switch

1. The basic conditions for the use of low-voltage isolation switches (1) The altitude does not exceed 1000 meters; (2) The ambient temperature is not higher than +40°C and not lower than -40°C; (3) The relative humidity is not more than 85% (relative to +20±5°C). 2. The low-voltage isolation switch is not suitable for the following ...

Tianyi switch - the role of low-voltage isolation switch Tianyi switch - the role of low-voltage isolation switch

1. Through the isolation switch, it plays a good insulating role, so that the whole circuit can be safe and secure, and the maintenance personnel or staff also have enough ability to repair the circuit. 2. At the same time, the low-voltage isolation switch can also change the operation mode of the circuit, which is used in the power plant or gas plant.

Tianyi switch - the characteristics of low-voltage isolation switch Tianyi switch - the characteristics of low-voltage isolation switch

1. When overhauling electrical equipment, provide an electrical interval and a visible disconnection point to ensure the personal safety of maintenance personnel. 2. The disconnector can not be operated with load: it cannot be operated with rated load or large load, and it cannot be divided or combined with load current and short circuit current.

Tianyi switch - common faults and troubleshooting methods of low-voltage switches Tianyi switch - common faults and troubleshooting methods of low-voltage switches

1 The contact is overheated Contact heat is mainly caused by the current flowing through the contact, and there is power loss between the contacts (such as contact resistance loss, arc energy loss). It is normal for the contacts to heat up, but severe heat (overheating) is a malfunction. The main ...

Tianyi switch - an introduction to the common types of low-voltage switches Tianyi switch - an introduction to the common types of low-voltage switches

1. Frame circuit breaker (universal type) - ACB: Rated current: In principle, frame circuit breakers are required for rated currents above 630A, and molded case circuit breakers are generally below 630A. It can be seen that the rated current of the frame circuit breaker is much larger, generally 630A-6300A. In addition in segments can ...

Tianyi switch - the high and low voltage division of low voltage switch Tianyi switch - the high and low voltage division of low voltage switch

36V is a safe voltage, but it cannot be used as a standard for dividing high and low voltages. There are two ways to divide high and low pressure: 1. According to the rated voltage: the rated voltage is 1000V and below is called low voltage; The rated voltage of 1000V or more is called high voltage. 2. According to the voltage of the equipment to the ground...

Tianyi switch - the environmental conditions of the high-voltage load switch Tianyi switch - the environmental conditions of the high-voltage load switch

1. Altitude: 2000m and below; 2. Ambient temperature: -25°C-+40°C; 3. Relative humidity: the daily average value is not more than 95%, and the monthly average value is not more than 90%; 4. Places without conductive dust, corrosive gases and water vapors; 5. No fire ...

Tianyi switch - the difference between high-voltage load switch and circuit breaker Tianyi switch - the difference between high-voltage load switch and circuit breaker

1. The high-voltage load switch can be broken with load and has the function of self-extinguishing arc, but its breaking capacity is very small and limited. 2. The high-voltage isolation switch is generally not able to break with load, there is no arc extinguishing cover in the structure, and there is also an isolation switch that can break the load.

Tianyi switch - precautions for high-voltage load switch Tianyi switch - precautions for high-voltage load switch

1. For vertical installation, the switch frame, closing mechanism, cable sheath, and protective steel pipe should be reliably grounded (not connected in series). 2. Before operation, several no-load opening and closing operations should be carried out, and each rotating part should be free of jamming, closing in place, and there should be enough safety distance after opening. ...

Tianyi switch - introduction to the characteristics of high-voltage load switch Tianyi switch - introduction to the characteristics of high-voltage load switch

1. It can isolate the power supply, have obvious disconnection points, and is mostly used for fixed high-voltage equipment. 2. It has an arc extinguishing device and a certain opening and closing speed, and can pass the normal working current and the specified short-circuit circuit in the closing state. 3. It is strictly forbidden to turn on and off the circuit with load.

Tianyi switch - what is the function of high-voltage load switch Tianyi switch - what is the function of high-voltage load switch

1. It can isolate the power supply, with a significant disconnection point, and is mostly used for fixed high-voltage devices; 2. It has arc extinguishing equipment and a certain opening and closing rate, and can pass through the normal working current and the specified short-circuit circuit in the case of closing; 3. It is forbidden to connect and cut off the circuit with load, ...

Next Page »
12345Next
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top