Tianyi switch - a measure to reduce the ripple and noise voltage of the switching power supply
Reduces EMI interference
The metal shell is used as a shield to reduce the interference of external electromagnetic field radiation. To reduce electromagnetic interference from the power line input, an EMI filter is added to the power supply input.
At the output, capacitors with good high-frequency performance and low ESR are used
The use of polymer solids ...
|
|
Tianyi switch - 9 tests and methods for switching power supply
1. Repeated short-circuit test
◆ Test instructions
The output of the module is short-circuited in various input and output states, the module should be able to achieve protection or retraction, repeated short-circuits, and after troubleshooting, the module should be able to automatically resume normal operation.
◆ Test Method
a ...
|
|
Tianyi switch - the use conditions and applicable places of low-voltage isolation switch
1. The basic conditions for the use of low-voltage isolation switches
(1) The altitude does not exceed 1000 meters;
(2) The ambient temperature is not higher than +40°C and not lower than -40°C;
(3) The relative humidity is not more than 85% (relative to +20±5°C).
2. The low-voltage isolation switch is not suitable for the following ...
|
|
Model introduction of Tianyi cam switch
LW42 series
LW42 series cam switch and safety switch are another series of high-quality products announced by Shanghai Tianyi Electric Appliance Co., Ltd. to meet customer needs.
Device function: personal safety is paramount, LW42 series cam switch and safety switch unique terminal plan ...
|
|
Tianyi switch - the characteristics of the disconnector are introduced
1. Provide an electrical interval and a visible disconnection point during electrical equipment maintenance to ensure the personal safety of maintenance personnel [3] .
2. The disconnector can not be operated with load: it cannot be operated with rated load or large load, and it cannot be divided and combined with load current and ...
|
|
Tianyi switch - the role of the disconnector switch
1. After opening, establish a reliable insulation gap to separate the equipment or line that needs to be overhauled from the power supply with an obvious disconnection point to ensure the safety of maintenance personnel and equipment.
2. According to the operation needs, change the line.
3. It can be used to divide and combine small currents in the line, ...
|
|
Tianyi switch - switching power supply failure and maintenance method
1. No output, the fuse is normal This phenomenon indicates that the switching power supply is not working or has entered the protection state. First of all, it is necessary to measure whether the starting pin of the power control chip has a starting voltage, if there is no starting voltage or the starting voltage is too low, it is necessary to check whether the starting resistance and the external components of the starting pin are ...
|
|
Tianyi switch - dual power supply automatic transfer switch normal working conditions
1) Ambient air temperature: The upper limit of ambient air temperature is +40°C, the lower limit of ambient air temperature is -5°C, and the average value of ambient air temperature for 24h does not exceed +35°C
2) Altitude: The altitude of the installation site does not exceed 2000m.
3) Atmospheric conditions: Atmospheric relative humidity in the surrounding air ...
|
|
Tianyi switch button - the color meaning of the button and indicator light and the place of use
1. Buttons
1. Red
Operation in hazardous situations. It is often used for emergency stops
Stop and break. It is often used to stop all machines, stop one or more motors, stop a certain part of a piece of equipment, make the electrical components lose power, and have a stop function reset button.
...
|
|
Tianyi switch - routine detection of air switch
The socket, lamp head, kitchen, bathroom, refrigerator, air conditioner of each route should be put out separately, and each route should have a separate air switch, high-power rooms, such as kitchens and bathrooms, the line of more than 4 square millimeters should reach 20A, and the general lamp head line should only be 16A, and each line ...
|
|
Tianyi switch - the allowable operating range of the disconnector
1. Pull together the voltage transformer and lightning arrester under normal conditions.
2. Pull together the 220kV no-load bus.
3. The neutral point of the transformer when there is no ground fault in the latching grid.
4. Pull the bypass current that is closed by a switch or an isolated switch.
5. Outdoor vertical splitting triple isolation ...
|
|
Q&A on Cam Switches and Load Disconnectors (11-21)
Q11: What is the maximum number of connecting rods for the rear mounting of P1 and P3?
A: Up to 4 sections can be added, each section is 25mm.
Q12: Does the P switch with SVB in the model come with PE grounding and N-wire terminals?
A: P switch models with SVB are equipped with PE grounding and ...
|
|
Tianyi switch - precautions for the use of proximity switches
1. If it is installed on metal, a certain space must be ensured to avoid interference between the proximity switch and the metal other than the detection object, resulting in failure. The metal parallel to the sensing surface must be 3 times the sensing distance from the sensing surface. The metal around the shaft of the proximity switch must be outside the cylinder, close to ...
|
|
Tianyi switch - what are the differences between limit switches and proximity switches?
First, the characteristics are different
1. Limit switch: The limit switch has the characteristics of small size, multiple functions, high precision, adjustable limit, strong versatility and easy maintenance, installation and adjustment.
2. Proximity switch: The proximity switch has the characteristics of a limit switch, and at the same time has the sensing performance.
|
|
What requirements should be met by Tianyi switch - disconnector?
(1) The disconnector should have an obvious disconnection point, which is easy to identify whether the electrical appliance is disconnected from the power grid.
(2) There should be reliable insulation between the disconnect points of the disconnector, that is, there should be enough distance between the disconnect points of the disconnector to ensure that it can work reliably under harsh climatic conditions, and ...
|
|
Tianyi switch - 5 methods to suppress ripple in switching power supply
1. Increase inductance and output capacitance filtering
According to the formula of the switching power supply, the current fluctuation in the inductor is inversely proportional to the inductance value, and the output ripple is inversely proportional to the output capacitance value. Therefore, increasing the inductance and output capacitance can reduce ripple.
In the same way, the output ripple is the same as the output ...
|
|
Tianyi switch - precautions for high-voltage load switch
1. For vertical installation, the switch frame, closing mechanism, cable sheath, and protective steel pipe should be reliably grounded (not connected in series).
2. Before operation, several no-load opening and closing operations should be carried out, and each rotating part should be free of jamming, closing in place, and there should be enough safety distance after opening.
...
|
|
What are the specifications and models of Tianyi switch - air switch?
1. Common air switch models in the family
Common family models: DZ series, C16, C32. C40, C80, C100, C120 and other products, of which C represents the starting current, such as: C32 means that the starting current is 32A, which can drive a 6500 watt water heater, C40 ...
|
|
Tianyi switch - the difference between the use of cam switch and load isolation switch
T-cam switches and P-block switches are used in a wide range of standard circuits and currents, and the number of combinations of cam switches is virtually unlimited. Different designs, front panels and dedicated switches ensure optimum sensitivity to meet the requirements.
Q1: P switch and T switch have ...
|
|
Tianyi switch - introduction to the characteristics of high-voltage load switch
1. It can isolate the power supply, have obvious disconnection points, and is mostly used for fixed high-voltage equipment.
2. It has an arc extinguishing device and a certain opening and closing speed, and can pass the normal working current and the specified short-circuit circuit in the closing state.
3. It is strictly forbidden to turn on and off the circuit with load.
|