Tianyi switch - the high and low voltage division of low voltage switch

Create Date: 2024-8-30 12:03:23|Source: TIANYI/TAYEE

36V is a safe voltage, but it cannot be used as a standard for dividing high and low voltages. There are two ways to divide high and low pressure:

1. According to the rated voltage: the rated voltage is 1000V and below is called low voltage; The rated voltage of 1000V or more is called high voltage.

2. According to the voltage of the equipment to the ground: the voltage of the equipment to the ground is 250V and below is low voltage; If the voltage of the equipment to the ground is above 250V, it is high voltage.

Usually what we call low-voltage electrical appliances is low-voltage electrical appliances with a rated voltage of less than 1000V, and high-voltage electrical appliances with a rated voltage greater than 1kV.
Tianyi switch - the high and low voltage division of low voltage switch

More on that
Tianyi switch - the difference between air switch and leakage protection switch Tianyi switch - the difference between air switch and leakage protection switch

1. Differences in appearance Although these two types of switches seem to be very familiar, but there are still differences, half of the leakage protection switch is the same as the air switch, and the other half is not, it is equipped with a test jump button and a recovery button, which are not available in the air switch. 2 ...

Tianyi switch - precautions for the use of proximity switches Tianyi switch - precautions for the use of proximity switches

1. If it is installed on metal, a certain space must be ensured to avoid interference between the proximity switch and the metal other than the detection object, resulting in failure. The metal parallel to the sensing surface must be 3 times the sensing distance from the sensing surface. The metal around the shaft of the proximity switch must be outside the cylinder, close to ...

Tianyi switch - the characteristics of the disconnector are introduced Tianyi switch - the characteristics of the disconnector are introduced

1. Provide an electrical interval and a visible disconnection point during electrical equipment maintenance to ensure the personal safety of maintenance personnel [3] . 2. The disconnector can not be operated with load: it cannot be operated with rated load or large load, and it cannot be divided and combined with load current and ...

Tianyi switch - the principle of electromagnetic interference generation and three control technologies of switching power supply Tianyi switch - the principle of electromagnetic interference generation and three control technologies of switching power supply

Generation and transmission of electromagnetic interference There are two ways of electromagnetic interference transmission: one is conducted transmission and the other is radiated transmission. Conducted transmission is a complete circuit connection between the interference source and the sensitive equipment, and the interference signal is transmitted to the receiver along the connected circuit.

Tianyi switch - the difference between fuse and air switch? Tianyi switch - the difference between fuse and air switch?

1. In addition to the short-circuit protection function of the fuse, the air switch can also realize the overload protection of the circuit. 2. The fuse is a one-time protection device, which must be replaced once it is blown and is very troublesome, so its reusability rate cannot be compared with the air switch. ...

The main features of VTeam X42 series limit switches The main features of VTeam X42 series limit switches

Uses: X42 series limit switches can be widely used in various types of mechanical equipment, automatic assembly lines and other light and medium load occasions, can detect the object action state, such as presence and absence, movement position, end of stroke, etc. Overview: The switch is mainly composed of switch operating parts, ...

Tianyi switch - the role of low-voltage isolation switch Tianyi switch - the role of low-voltage isolation switch

1. Through the isolation switch, it plays a good insulating role, so that the whole circuit can be safe and secure, and the maintenance personnel or staff also have enough ability to repair the circuit. 2. At the same time, the low-voltage isolation switch can also change the operation mode of the circuit, which is used in the power plant or gas plant.

New Upgrades - A new member of the warning light family reports New Upgrades - A new member of the warning light family reports

JD series warning light is Tianyi electrical appliances in the field of signal control launched high-performance products, once launched, it has won the unanimous favor of customers, products in the design, manufacturing, quality control and other aspects of the company's quality system has always been under the strict testing and supervision of the company's quality system, to ensure that each product ...

Tianyi switch - the performance and main features of dual power automatic transfer switch Tianyi switch - the performance and main features of dual power automatic transfer switch

performance 1. Adopt double-row composite contacts, cross-connected mechanisms, micro-motor pre-energy storage and micro-electronic control technology, basically achieve zero arcing (no arc extinguishing cover); 2. Adopt reliable mechanical interlocking and electrical interlocking technology; 3. Adopt zero-crossing technology; 4、 ...

Tianyi switch - the difference between high-voltage load switch and circuit breaker Tianyi switch - the difference between high-voltage load switch and circuit breaker

1. The high-voltage load switch can be broken with load and has the function of self-extinguishing arc, but its breaking capacity is very small and limited. 2. The high-voltage isolation switch is generally not able to break with load, there is no arc extinguishing cover in the structure, and there is also an isolation switch that can break the load.

Tianyi switch - common faults and troubleshooting methods of low-voltage switches Tianyi switch - common faults and troubleshooting methods of low-voltage switches

1 The contact is overheated Contact heat is mainly caused by the current flowing through the contact, and there is power loss between the contacts (such as contact resistance loss, arc energy loss). It is normal for the contacts to heat up, but severe heat (overheating) is a malfunction. The main ...

Tianyi switch - the difference between disconnector and circuit breaker Tianyi switch - the difference between disconnector and circuit breaker

1. The circuit breaker is equipped with an arc extinguishing device, so the circuit breaker can be operated with load, but it cannot operate the current of the load. The disconnector does not have an arc extinguishing device, and it can operate places where the load current is less than 5A, but it is generally not suitable for operation with load. 2. And the circuit breaker ...

Tianyi switch - the operation method of dual power automatic transfer switch Tianyi switch - the operation method of dual power automatic transfer switch

First, first place the dual power supply on the adjustment table, and the phase wire and the neutral wire (neutral line) are docked in place, and can not be connected wrongly. Second, after the line is connected, it is necessary to check the installed line, and then turn on the main switch of the debugging station to turn on the common and standby working power supply. Three, when the double ...

Tianyi button indicator - button indicator induction circuit fault and solution Tianyi button indicator - button indicator induction circuit fault and solution

First, the reason for the fault of the induction circuit of the switch button indicator 1. Aging of circuit board: The circuit board of the switch button indicator induction circuit board may be aged if it has been used for too long, resulting in leakage in the circuit, and then the induction failure of the indicator light. 2. Sense ...

Tianyi switch - the structural characteristics of high-voltage load switch Tianyi switch - the structural characteristics of high-voltage load switch

The load switch and combination electrical appliances are mainly composed of frames, isolation switches (the current limiting fuse of the combination is on the isolation switch), vacuum switch tubes, grounding switches, spring operating mechanisms, etc. The product has compact structure, small size, long life, strong closing and breaking ability, and simple operation and maintenance.

Tianyi switch - the reason why the air switch trips and cannot be pushed Tianyi switch - the reason why the air switch trips and cannot be pushed

1. What is the reason why the empty trip cannot be pushed? 1. If the air opening itself is faulty or damaged, the air opening should be replaced with a new one. 2. If the line is caused by a short circuit, the line should be found first, and then reconnected.

Tianyi switch - an introduction to the common types of low-voltage switches Tianyi switch - an introduction to the common types of low-voltage switches

1. Frame circuit breaker (universal type) - ACB: Rated current: In principle, frame circuit breakers are required for rated currents above 630A, and molded case circuit breakers are generally below 630A. It can be seen that the rated current of the frame circuit breaker is much larger, generally 630A-6300A. In addition in segments can ...

Tianyi switch - what are the differences between limit switches and proximity switches? Tianyi switch - what are the differences between limit switches and proximity switches?

First, the characteristics are different 1. Limit switch: The limit switch has the characteristics of small size, multiple functions, high precision, adjustable limit, strong versatility and easy maintenance, installation and adjustment. 2. Proximity switch: The proximity switch has the characteristics of a limit switch, and at the same time has the sensing performance.

Tianyi switch - precautions for switching power supply to regulate current Tianyi switch - precautions for switching power supply to regulate current

1. Pay attention to stability When adjusting the output current of the switching power supply, the stability of the circuit must be ensured, otherwise there will be current fluctuations, disturbances and other phenomena, which will affect the normal operation of electronic equipment. Therefore, it is necessary to perform a ...

Tianyi Switch - Cam Switch and Load Disconnector Q&A (1-10) Tianyi Switch - Cam Switch and Load Disconnector Q&A (1-10)

Q1: What is the difference between P switch and T switch? A: P switch is a load isolation switch, mainly used for the opening and isolation of the main circuit load, only 3P and 3+N, can add auxiliary contacts; The T-switch is a multi-function switch with a wide variety of contact sequences, modular contact units, which can ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top