1. Through the isolation switch, it plays a good insulating role, so that the whole circuit can be safe and secure, and the maintenance personnel or staff also have enough ability to repair the circuit.
2. At the same time, the low-voltage isolation switch can also change the operation mode of the circuit, which is widely used in power plants or gas plants. For example, if the production line needs to change the product specification or model scheduling, then the disconnector is needed to change the operation mode of the circuit by cutting off the power supply. Maximize the efficiency of the circuit by scheduling the operation mode.
3. According to the different functions and structure types, the high-voltage isolation switch can be divided into outdoor high-voltage isolation switch and indoor high-voltage isolation switch. The outdoor disconnector has strong adaptability and relatively higher quality, so it can withstand natural weather changes. For example, natural weather such as wind, rain, thunder and lightning. Generally speaking, outdoor high-voltage disconnectors are installed in the open air, in the suburbs or on terraces. The indoor high-voltage disconnector is a common switch in our family life, which is cheaper in cost and easy to operate.
4. In addition to its ability to segment the line, it can also connect the line. In the low-voltage equipment of residential buildings or general buildings, disconnectors reduce the hidden danger of safety accidents through non-manual operation. So it is convenient for our life and the operation of power distribution and transmission.
|
More on that
|
Tianyi switch - switching power supply failure and maintenance method
1. No output, the fuse is normal This phenomenon indicates that the switching power supply is not working or has entered the protection state. First of all, it is necessary to measure whether the starting pin of the power control chip has a starting voltage, if there is no starting voltage or the starting voltage is too low, it is necessary to check whether the starting resistance and the external components of the starting pin are ...
|
|
Tianyi switch - the difference between the use of cam switch and load isolation switch
T-cam switches and P-block switches are used in a wide range of standard circuits and currents, and the number of combinations of cam switches is virtually unlimited. Different designs, front panels and dedicated switches ensure optimum sensitivity to meet the requirements.
Q1: P switch and T switch have ...
|
|
Tianyi Switch - Cam Switch and Load Disconnector Q&A (1-10)
Q1: What is the difference between P switch and T switch?
A: P switch is a load isolation switch, mainly used for the opening and isolation of the main circuit load, only 3P and 3+N, can add auxiliary contacts; The T-switch is a multi-function switch with a wide variety of contact sequences, modular contact units, which can ...
|
|
What are the advantages of Tianyi switch - limit switch?
1. The design is usually simple and straightforward
2. Works well in almost any industrial environment
3. It has high accuracy and repeatability
4. Low-power devices
5. High inductance load can be switched
6. Used to switch multiple loads
7. Simple installation
...
|
|
Tianyi switch - the characteristics of the disconnector are introduced
1. Provide an electrical interval and a visible disconnection point during electrical equipment maintenance to ensure the personal safety of maintenance personnel [3] .
2. The disconnector can not be operated with load: it cannot be operated with rated load or large load, and it cannot be divided and combined with load current and ...
|
|
Tianyi switch - the principle of electromagnetic interference generation and three control technologies of switching power supply
Generation and transmission of electromagnetic interference
There are two ways of electromagnetic interference transmission: one is conducted transmission and the other is radiated transmission. Conducted transmission is a complete circuit connection between the interference source and the sensitive equipment, and the interference signal is transmitted to the receiver along the connected circuit.
|
|
Tianyi switch - precautions for the use of proximity switches
1. If it is installed on metal, a certain space must be ensured to avoid interference between the proximity switch and the metal other than the detection object, resulting in failure. The metal parallel to the sensing surface must be 3 times the sensing distance from the sensing surface. The metal around the shaft of the proximity switch must be outside the cylinder, close to ...
|
|
Tianyi switch - the difference between fuse and air switch?
1. In addition to the short-circuit protection function of the fuse, the air switch can also realize the overload protection of the circuit.
2. The fuse is a one-time protection device, which must be replaced once it is blown and is very troublesome, so its reusability rate cannot be compared with the air switch. ...
|
|
Tianyi switch - what are the functions of limit switches?
1. Protection
The most important role of the limit switch must be its protection effect, the limit switch is also known as the travel limit switch, which is mainly used to control the stroke of mechanical equipment and limit protection. In practice, the travel limit switch is installed in a pre-arranged position, and the travel limit switch is installed in a pre-arranged position.
|
|
Tianyi switch - routine detection of air switch
The socket, lamp head, kitchen, bathroom, refrigerator, air conditioner of each route should be put out separately, and each route should have a separate air switch, high-power rooms, such as kitchens and bathrooms, the line of more than 4 square millimeters should reach 20A, and the general lamp head line should only be 16A, and each line ...
|
|
Tianyi switch - the working condition of the air switch
Ambient air temperature: upper ambient air temperature +40°C; The lower limit of ambient air temperature is -5°C; The average temperature of the ambient air for 24 hours does not exceed +35 ° C.
Altitude: The altitude of the installation site does not exceed 2000m.
Atmospheric conditions: Atmospheric relative humidity at ambient air temperature of +4 ...
|
|
Tianyi switch - the environmental conditions of the high-voltage load switch
1. Altitude: 2000m and below;
2. Ambient temperature: -25°C-+40°C;
3. Relative humidity: the daily average value is not more than 95%, and the monthly average value is not more than 90%;
4. Places without conductive dust, corrosive gases and water vapors;
5. No fire ...
|
|
Tianyi switch - how to choose the right industrial switching power supply?
1. First of all, it is necessary to select the appropriate input voltage specification;
2. Choose the right power. In order to extend the service life of the power supply, it is necessary to select an additional type with 30% of the rated output power.
3. Consider the load characteristics. The load added is a motor, bulb or capacitive load, and the current at start-up ...
|
|
New product release of TPB1TPL1 button signal light
TPB1 series pushbutton switch is designed by VTeam's senior R&D technical team, which is suitable for a variety of industries and various occasions. TPB1 series pushbutton switches have a complete range of colors, rich colors, economic and durable, easy installation and superior performance. Automated production, testing, and quality control are more stringent, and the products are ...
|
|
What are the specifications and models of Tianyi switch - air switch?
1. Common air switch models in the family
Common family models: DZ series, C16, C32. C40, C80, C100, C120 and other products, of which C represents the starting current, such as: C32 means that the starting current is 32A, which can drive a 6500 watt water heater, C40 ...
|
|
Tianyi switching power supply troubleshooting
1. Check the key points:
1) Whether the voltage at point B is 310V.
2) Whether the 15V voltage is normal.
3) Whether the voltage at point C is greater than 14V.
4) Whether the SS terminal of (8) pin IC6 is higher than 10V, whether the SD terminal of pin (10) is lower than 0.6V, and whether there is a square wave transmission at pin 13 and pin 14 ...
|
|
Tianyi switch - the precautions required for the operation of dual power automatic transfer switch
1. When closing, first of all, attention should be paid to check that the circuit breaker that can be connected to the dual-power automatic transfer switch is indeed in the opening position, and then quickly operate the risk isolation switch to close it (whether the enterprise adopts manual management agency or leveraged financial institution personnel operation), but ...
|
|
Tianyi switch - the role of the disconnector switch
1. After opening, establish a reliable insulation gap to separate the equipment or line that needs to be overhauled from the power supply with an obvious disconnection point to ensure the safety of maintenance personnel and equipment.
2. According to the operation needs, change the line.
3. It can be used to divide and combine small currents in the line, ...
|
|
Tianyi switch - the classification of dual power transfer switches
It is mainly divided into ATS and STS.
STS static toggle switch
STS (Static Transfer Switch), also known as static transfer switch. The STS automatically switches to the second channel to supply power to the load after the first channel fails.
|
|
Tianyi switch - the model meaning of the proximity switch is introduced
Unmarked/Z: Inductive/inductive self-diagnosis
C/CZ: Capacitive/Capacitive Self-Diagnosis
N: NAMUR safety switch
X: Analog
F: Hall
V: Reed type
J: Threaded cylindrical
B: Cylindrical
Q: Angular cylindrical shape
...
|
|