Mitsubishi inverter encountered problems and solutions

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

1. If you want to use the inverter to drive the motor with a capacitor to improve the power factor, but the motor does not move, please explain the reason.

As a countermeasure, remove the capacitor and work to improve the power factor, and it is useful to connect an AC reactor to the input side of the inverter to improve the power factor.

                            Mitsubishi inverter encountered problems and solutions

2. How long is the life of the inverter?

Inverters are stop devices, but they also have consumable devices such as filter capacitors and cooling fans, and if they are regularly maintained, they can be expected to have a life span of more than 10 years.

3. There is a cooling fan in the inverter, what is the direction of the wind? What happens if a fan breaks?

For small capacities, there are also models without cooling fans. For models with fans, the direction of the wind is from the bottom up, so do not place machinery that interferes with suction and exhaust in the upper and lower parts of the area where the inverter is installed. Also, do not place heat-sensitive parts above the inverter. When there is a problem with the fan, the fan stops detecting or cooling the fan is overheated for maintenance

4. The filter capacitor is a consumable, so how to judge its life?

The capacitance of a capacitor used as a filter capacitor decreases over time, and the capacitance is measured regularly to determine the life of the capacitor when it reaches 85% of the rated capacity of the product.

5. Whether there is any restriction on the installation direction when installing the inverter.

It should be basically stored in the plate, but the problem is that the plate with a fully enclosed structure is large, occupies a large space, and the cost is relatively high. The measures include:

(1) The planning of the disc should be based on the heat dissipation required by the actual equipment;

(2) Use aluminum heat sinks, fin coolants, etc. to increase the cooling area;

6. What is the function of the inverter DC reactor?

Reduce the higher harmonic interference of the input current and improve the power factor of the input power supply.

More on that
Mitsubishi PLC FAQs Mitsubishi PLC FAQs

1. How to connect a PNP three-wire proximity switch to the input port of FX3U PLC. Answer: The signal output termination of the PNP three-wire system close to the switch is connected to the input port of the PLC, such as X0, and the 0V end of the PNP type close switch to the 0V terminal on the PLC, and the S/S terminal and the 0V terminal ...

Mitsubishi catalogue of some small PLC models and commonly used touch screens Mitsubishi catalogue of some small PLC models and commonly used touch screens

Commonly used touch screen model description Economical touch screen GS2107-WTBD 7 inch widescreen, 800*480, 65535 colors, USB/232/422/Ethernet, DC Pass through...

Ground leakage current of Mitsubishi inverter and countermeasures thereof Ground leakage current of Mitsubishi inverter and countermeasures thereof

There is electrostatic capacitance between the input and output wiring of Mitsubishi inverters and other wires, between the ground and the motor, and there is a leakage current flow. The leakage current value is affected by factors such as electrostatic capacitance and carrier frequency, and the leakage current is high when the carrier frequency of the inverter is set high and the leakage current is operated under low noise conditions.

Mitsubishi inverter heat dissipation causes and countermeasures Mitsubishi inverter heat dissipation causes and countermeasures

1. Whether there is abnormal change in the sound during the operation of the equipment, including whether there is oscillation during the operation of the motor. 2. Whether the ambient temperature of the inverter installation is too high or too low, the working temperature is generally required to be in the range of -10°C - +40°C, and it is better to be about 25°C. ...

The difference between Mitsubishi PLC source type and leak type The difference between Mitsubishi PLC source type and leak type

Mitsubishi PLC split source type (PNP) or drain type (NPN), here are their differences 1: Leakage logic: When the current flows out of the signal input terminal, the signal becomes ON, which is leakage logic. The current flows through the terminals and has the output characteristics of an NPN transistor. 2: Source logic: When ...

Mitsubishi inverter FR-E700 series is selected Mitsubishi inverter FR-E700 series is selected

Q: When will I choose the E740 series inverter? A: E700 is an economical and small inverter with high driving performance, with the function of holding the brake, and can also add options to expand the function, which can be used for transportation, lifting occupations, and has high cost performance. Q: Mitsubishi inverter E740 should ...

PLC Programming Recommendations – Mitsubishi PLC PLC Programming Recommendations – Mitsubishi PLC

1. When the PLC and the host computer (or touch screen) form a monitoring system, there are many hours on the screen that require "manual", "active" and other control forms (generally more than one). In the program, you can use the "MOV" command. For example, when selecting "manual", the constant 1 MOV will be changed to a ...

Mitsubishi touch screen common faults and solutions Mitsubishi touch screen common faults and solutions

Fault 1: Mitsubishi touch screen contact deviation Phenomenon: The direction of finger contact does not match the mouse arrow. Analysis: When calibrating the orientation after installing the screwdriver, there is no vertical contact with the bull's-eye. Solution: Recalibrate the bearing. ...

PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi

The PLC control cabinet is the final level of equipment in the power distribution system. It mainly protects, supervises and controls the entire circuit, which is convenient for unified management. The power distribution cabinet is a kind of equipment that can reasonably distribute electrical energy and make the circuit easy to open and close. But because it is a circuit device, the requirements for the level of safety protection ...

Characteristics of servos and advantages of Mitsubishi servos Characteristics of servos and advantages of Mitsubishi servos

The servo system is an automatic control system that enables the output of the object's orientation, direction, and state to change with the arbitrary change of the input quantity (or given value). In the automatic control system, the system that can echo the control signal with a certain degree of accuracy is called the follow-up system, also known as the servo system.

Mitsubishi drive functions and functions Mitsubishi drive functions and functions

1. Control the start, stop, speed and so on of the servo motor; 2. Carry out various maintenance on the motor (overload, short circuit, undervoltage, etc.) 3. Respond to external signals, and control the servo motor (position, speed, torque) after internal PID conditioning; The manipulator is the control of the electric ...

Mitsubishi Electric one-click adjustment user instruction mode tuning method Mitsubishi Electric one-click adjustment user instruction mode tuning method

1. Set PA08 to 0003 and set the gain adjustment form to; , the function is to prevent the failure of the active calculation of the inertia ratio, and the alarm C005 will be given. 2. Flip it over; menu; , set the speed/acceleration and deceleration/movement amount, according to the actual situation ...

Mitsubishi MELSEC iQ-F makes IoT a simple one Mitsubishi MELSEC iQ-F makes IoT a simple one

The MELSEC iQ-F series of small PLCs completes the high-speed system bus, supports a variety of networks, enriches the built-in functions, and makes it more convenient to use. From stand-alone use to network-based system proposals, we strongly support the needs of customers for "cutting-edge products in the manufacturing industry". Using the MELSEC iQ-F...

Mitsubishi FR-E800 product model introduction Mitsubishi FR-E800 product model introduction

1、3相200V FR-E820-[]K (E)   FR-E820-0.1K、FR-E820-0.2K、FR-E820-0.4K、FR-E820-0.75K、FR-E820-1.5K、   FR-E820-2.2K、FR-E820-3.7K、FR-E820-5.5K、FR-E820-7.5K、FR-E820-11K、 ...

The working principle of the servo motor of the Mitsubishi CNC system The working principle of the servo motor of the Mitsubishi CNC system

1. The servo mainly relies on the pulse to position, basically it can be understood in this way, the Mitsubishi CNC system repair servo motor receives 1 pulse, it will rotate the angle corresponding to 1 pulse, and then complete the displacement, because, the servo motor itself has the function of announcing the pulse, so the servo motor ...

Mitsubishi servo system failure type Mitsubishi servo system failure type

The origin orientation is incorrect, and the encoder debugs/zeros the bit Replacement of bearings, wear of bearing grooves, cracking of the rotor, cracking of the shaft Gear groove wear The magnet bursts steel, the magnet falls, gets stuck and doesn't move Encoder wear, code/glass disc wear and crack ...

Precautions for the use of Mitsubishi servo motor with brake Precautions for the use of Mitsubishi servo motor with brake

1. Occasions with brake servo motors: The servo motor is mainly loaded by the motor shaft, assuming that the load driven by the motor shaft is vertical, after the whole control system is powered off, the load on the servo motor shaft will be driven to run down under the action of gravity, so that ...

Performance comparison of Mitsubishi servo motors Performance comparison of Mitsubishi servo motors

First, the control accuracy is different The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors, which are also some functions, have a smaller step angle after segmentation. ...

Mitsubishi inverter OC causes the failure Mitsubishi inverter OC causes the failure

1. The ERR problem is an under-voltage problem, which is usually caused by the problem of voltage detection loop resistance or wiring, rather than the actual input voltage showing undervoltage. Most of the OC problems of the A200 series are caused by the damage of the drive circuit, and its drive circuit ...

Mitsubishi PLC and inverter are communication methods Mitsubishi PLC and inverter are communication methods

The output point and COM point of PLC (MR type or MT type) are directly related to the STF (forward rotation engine) of the inverter. overflow-wrap: break-word !important; ">. RH (high speed), RM (medium speed) important; overflow-wrap: break-word !important; ">、R ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top