(1) Single busbar. Single busbar, single bus segment, single bus plus bypass, and single bus segment plus bypass.
(2) Double busbar. Double-busbar, double-busbar segmentation, dual-busbar plus bypass, and dual-busbar segmentation plus bypass.
(3) 3/2 wiring.
(4) 4/3 wiring.
(5) Bus, transformer, and generator unit wiring.
(6) Bridge wiring. Inner bridge wiring, outer bridge wiring, double bridge wiring.
(7) Angular wiring (or ring). Triangular wiring, quadrangular wiring, polygonal wiring.
|
More on that
|
Wiener looks at the busway drawing method
First, in the CAD system drawing, it is a plan of the bus duct, and two parallel polylines can indicate the bus duct.
2. The busway includes the following parts:
1. Feeder busbar, which is used to transmit electricity
2. Plug-in busbar with plug-in interface above, ...
|
|
Busbar system reverse operation – Wiener
(1) For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...
|
|
Specific optimization application of ship unloader bus system - Wiener
1. Bus system 1
The bus adapter used in bus system 1 is more miscellaneous, and -Q1 selects a bus type blocking switch that can be directly attached to the bus; -Q11 is a 3VL2 switch, select an appropriate universal adapter to hook up to the bus; The 3-pole switch-Q12——-Q15 is less than 63A, but ...
|
|
Advantages of installing cable trays with busway – Wiener
When it comes to cable tray installation, wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows:
1. Convenient connection of bus duct: the so-called plug-in bus duct, fireproof bridge is the way it uses plugged in.
|
|
Introduction to busbars in Wiener's electrical system
The bus bar is an intermediate link in the voltage distribution device at all levels, and its role is to gather, distribute and transmit electric energy. It is mainly used for the connection of the electrical main circuit between the power plant generator outlet line and the main transformer, the plant transformer and the distribution box, also known as the busbar.
...
|
|
Considerations for purchasing a busbar system – Wiener
The bus system plays a very important role in the practice of construction, and for products such as the bus system, the relevant items can not be ignored, so that we can better use the practical value of this type of product. Generally speaking, when we are purchasing a bus system ...
|
|
Knowledge points of Wiener busway
Busway was born in the United States, first put into practical use in Japan, and then spread all over the mountains and regions in prosperous countries and regions. So what is a busway? Busway is a high-current trunk tappable power supply system, usually made of a metal housing (iron or aluminum).
|
|
Bus load forecasting method and characteristics - Wiener
Bus load guessing is a kind of power system load guessing, and the bus system load can be defined as the sum of the terminal load supplied by the main transformer of the substation to a relatively small power supply area, which is the refinement of the system load. Bus load guessing generally only carries out short-term load guessing, and the result is ...
|
|
Characteristics of power system bus wiring mode
(1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, less investment, convenient operation and expansion, but its reliability and activity are poor. When the bus or bus divider is faulty or overhauled, it is necessary to disconnect all power to the bus.
...
|
|
The difference between busway and silicone rubber inverter cable - Vernal
The internal bus duct uses high-quality T2 electrolytic copper as the transmission conductor, which has high purity, high conductivity, low loss and small heating, which is very suitable for industrial and mining enterprises that need large current load operations.
|
|
Difference Between Busbar and Busway – Vernal
The connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, mostly use bare wires or stranded wires of rectangular or circular cross-section, which are collectively referred to as busbars.
The role of the bus bar is to collect, distribute and transmit electrical energy. Because the busbar ...
|
|
Difference Between Busbar and Cable – Vernal
When the busway has not been developed and introduced, the cable is still an indispensable figure in the low-voltage distribution system, when the busway system is introduced and widely used. Whether to choose the cable or the bus duct has become a topic of endless debate. So it's hard to say which of the two is better ...
|
|
The difference between busway and busbar - Vernal
The busway and busbar are actually closed one after the other, and the other is not closed.
Closing the busbar is referred to as the busway, which means that the busway is the vest that closes the busbar, and the closing busway and the busbar refer to the same thing.
...
|
|
Wiener is a common way to wiring busbars
Single bus wiring method: all outgoing wires are connected to the same busbar, which is also the most cost-effective and simplest wiring method
Single bus segmentation: The outgoing line is arranged in two parts on different sections of the single busbar, so that a power failure in the meantime does not affect the power supply of the other bus
...
|
|
Uses and technologies of cable junction boxes – Wienal
XBT series mine flameproof communication cable distribution box has the characteristics of small size, reasonable cable import and export, and wide coverage. Each distribution box has 4-10 inlet and outlet bells, which is suitable for HUYV type mine signal cable in coal containing sexual gas (methane) mixture (non-mining face).
|
|
Types of corrosion of Wiener tubular busbars
Tubular bus is a new type of equipment that is widely used in our current days, and it itself has the characteristics of high current, outstanding insulation and wide range of application, so we don't seem to be too worried about its function and role when using it. But there is one thing that needs to be ...
|
|
Lighting power busway service life - Wienal
The system consists of a current box, a bus body, a branch plug and device accessories.
When the heat dissipation of conductive copper strip has been effectively improved, the contact between the copper strip and the inner wall of the tube is reduced, and the insulation resistance and anti-aging ability of the tube body are strengthened, so as to prolong the service life of the pipe body. The life of the tube far exceeds ...
|
|
What are the hazards of 220V DC in the bus system - Wiener
The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system.
In the DC system, the positive and negative poles of DC are insulated from the ground, and there is no grounding current when generating a ground current when one pole is grounded.
|
|
The service life of the lighting power busway – Wienal
The system consists of a current box, a bus body, a branch plug and device accessories.
When the heat dissipation of conductive copper strip is effectively improved, the contact between the copper strip and the inner wall of the tube is reduced, the insulation resistance and anti-aging ability of the tube body are strengthened, and then the service life of the tube body is extended. The longevity of the tube far exceeds ...
|
|
Comparison of several insulated tubular busbars
The use of insulated tube bus in China has a history of nearly 20 years, and it has made a historic contribution to reducing the layout space of the distribution bus and improving the reliability of the bus operation. There are many manufacturers who supply this product, and their production processes are uneven, and the differences in processes are mainly reflected in the ...
|
|