The difference between the busbar system and the traditional wiring

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The advantages of the busbar system are:

1. The Wiener bus system adopts the bus bar non-perforation connection technology, and the electrical components are firmly connected to the busbar;

2. It saves the device space, saves the redundant wiring, saves the device time and labor;

3. The busbar is used as both a conductive element and a hook-up element, killing two birds with one stone.

                               The difference between the busbar system and the traditional wiring

The disadvantages of traditional wiring methods are:

1. Punching holes on the bus reduces the current carrying capacity of the busbar, and compared with the bus system, the same current load must be selected with a larger cross-section.

2. The wiring is redundant, the device is messy, time-consuming and labor-intensive, and the device space is significantly increased;

More on that
Busbar wiring problems of busbars - Vernal Busbar wiring problems of busbars - Vernal

Bus, transformer, generator set unit wiring. It has the characteristics of simple wiring, less switchgear, easy operation, suitable for expansion, and because there is no generator outlet voltage bus, the short-circuit current of the low-voltage side of the generator and the main transformer is reduced. ...

Difference Between Busbar and Cable in Power System – Wiener Difference Between Busbar and Cable in Power System – Wiener

Busbar refers to a product made of copper (copper bar) and aluminum materials with high conductivity to transmit electric energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the electrical energy output from generators, transformers or rectifiers is delivered to individual users.

Power system bus wiring features - Wiener Power system bus wiring features - Wiener

1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, small investment, convenient operation and conducive to expansion, but the reliability and flexibility are poor. When there is a fault or maintenance of the bus bar or bus barrier switch, the full power supply of the bus must be disconnected. ...

The common DC bus of the inverter system - Wiener The common DC bus of the inverter system - Wiener

1. Three-phase AC power supply inlet The power input of each inverter is connected in parallel on the same AC bus, and the power supply phase of the input of each inverter is consistent. In Figure 3, the circuit breaker QF is the incoming protection device for each inverter. LR is an incoming reactor, when multiple inverters are in the same ...

The difference between busway and silicone rubber inverter cable - Vernal The difference between busway and silicone rubber inverter cable - Vernal

The internal bus duct uses high-quality T2 electrolytic copper as the transmission conductor, which has high purity, high conductivity, low loss and small heating, which is very suitable for industrial and mining enterprises that need large current load operations.

Some of the Wiener series models Some of the Wiener series models

  05802 Insulator with female thread, bolt, M8, height 35mm 08824 Platen connector for PE- and N-busbar 01 932   08825 Snap-on fastener, for PE- and N-busbars 01126-01129 and 019 ...

Wiener enclosed busbar installation Wiener enclosed busbar installation

Closed busway is a busbar system composed of metal plates (steel plates or aluminum plates) as protective shells, conductive strips, insulating materials and related accessories. It can be made into a piercing closing bus with spaced piercing junction boxes, or a feed-in closing bus without a junction box in the middle. ...

Wiener bearing repair technology Wiener bearing repair technology

1. Comprehensive correction of bearings The comprehensive correction of the bearing includes the comprehensive and strict correction process of the damaged bearing after cleaning, dismantling, inspection, roller table grinding or replacement of inner and outer rings, new rolling element manufacturing/original rolling element grinding, rolling element replacement, assembly, clearance adjustment and inspection and packaging.

Standard parameters of busway specification - Wiener Standard parameters of busway specification - Wiener

1. The standard scale of the bus duct This specification regulates the terminology, skill requirements and test methods of the insulated bus trunk system (bus duct) and its plug-in feed box (hereinafter referred to as the feed box). This specification specification applies to additional voltage AC to 660V...

Application and technical requirements for bus protection on the low voltage side - Wiener Application and technical requirements for bus protection on the low voltage side - Wiener

1. The use status of bus maintenance on the low-voltage side According to the national standard "Code for Relay Maintenance and Automatic Equipment Design of Power Equipment" (GB50062-92): about the 3-10kV bus and the double bus running in parallel of the power plant and the primary substation, as long as the following conditions are installed.

Precautions for busway installation Precautions for busway installation

1. Requirements for civil engineering before installation 1. The foundation, frame, reserved holes and embedded parts meet the planning requirements of electrical equipment. 2. After the construction of the roof and floor slab, there shall be no leakage. 3. After the indoor above-ground construction is completed, mark the leveling elevation on the wall on the ground.

The busway power system is a key component - Wiener The busway power system is a key component - Wiener

The busway is one of the more critical components in the power system, and it is an important part of connecting cables to important equipment such as substations, overhead lines, transformers, circuit breakers, etc. It is widely used in various power systems, mainly for the reliable operation of power systems. ...

Applications in the power of busbar systems – Vernal Applications in the power of busbar systems – Vernal

The bus refers to the connection of voltage transformers and other voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, and most of the bare wires or stranded wires with rectangular or circular cross-sections are selected. Follow the lines ...

Vernal fuse replacement method Vernal fuse replacement method

1. Prepare for replacement. For example, construction personnel should wear labor protection equipment, such as insulating gloves. 2. Confirm the fault type. Check the distribution box with a test pen first, confirm that there is no leakage, and then open the distribution box door. Then use the voltage tester to detect the three-phase power supply, if the three-phase ...

Differences and differences between busway and other busbars Differences and differences between busway and other busbars

The busbar and busway are actually one open and one closed, and the other is not closed. The closed busway is referred to as the busway, that is, the busway is sealed The closure of the busbar, the closure of the busbar and the busway all refer to the same east...

Features of Wiener busway Features of Wiener busway

The Wiener busway mainly acts on the aluminum conductor, which has a large current capacity and good electrical and mechanical properties. In addition, it uses a metal trough as the shell, so it is non-flammable, safe and reliable, and has a long service life. Compared with traditional power distribution, the equipment occupies a significantly smaller area and has a beautiful appearance. ...

Advantages of installing cable trays with busway – Wiener Advantages of installing cable trays with busway – Wiener

When it comes to cable tray installation, wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plug-in bus duct, fireproof bridge is the way it uses plugged in.

The difference between air-type busway and dense busway - Vernal The difference between air-type busway and dense busway - Vernal

1. The insulating medium is different: there is a certain open space between the copper bars of the air bus duct, that is to say, the insulation between the copper bars mainly depends on air, and the insulation medium between the copper bars of the dense bus duct (many people call it a closed bus duct) is an organic insulating material. 2. Copper bar placement ...

Operating regulations for the use of busbars - Wiener Operating regulations for the use of busbars - Wiener

1. Charging to the bus should be carried out with a switch (bus tie, bypass or line switch) with snap-action maintenance that reflects various types of faults. Before charging the bus, it should be considered whether the system may be unstable if the charging bus trips, and if necessary, the active power flow of the relevant line can be reduced. ...

Difference Between Fuse and Circuit Breaker – Vernal Difference Between Fuse and Circuit Breaker – Vernal

The principle of the fuse is to use the current to flow through the conductor to heat the conductor, and the conductor is ablated after reaching the melting point of the conductor, so the electrical appliances and circuits used for circuit maintenance are not burned out. It is an accumulation of heat, so it is also able to complete overload maintenance. Once...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top