Aluminum alloy busway circuit continuity - Wiener

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The continuity of the aluminum alloy bus duct maintenance circuit is related to the PE line, and the crossover PE wire conductor bus of the maintenance conductor and the two-unit bus bar should reach 50% of the phase line, the equivalent cross-sectional area. The continuity resistance of the maintenance circuit between the shell and the PE line ≤ 0.005 ohms, and the unit with jumper wires is not less than the equivalent cross-sectional area of the PE line of the maintenance conductor.

                               Aluminum alloy busway circuit continuity - Wiener

In addition to the incident current of all the power supply equipment of the line from the PE conductor of the bus, the PE wire is used for the safety maintenance of the bus duct, so different PE conductor standards are set according to different current standards to ensure the current dissipation at the end of the line. The fast action of the switch that provides the signal to the bus cuts off the power supply, and the rapid dispersion of the current at the end of the incident. Ensure the safety of people with low terminal voltage. Therefore, when planning and selecting the busway, it is required to ensure the safety and stability of the power supply system.

Temperature control maintenance, the most important technical indicator of the bus duct is the temperature rise, how do you control the bus duct to run at low temperature, how to determine that the products supplied by the bus duct manufacturer can run at full load and reach the temperature rise value you require, this is the most critical problem.

More on that
Wiener busway plug-in box wiring method Wiener busway plug-in box wiring method

The bus duct bracket has to be firmly installed, and the bus duct should be correctly placed according to the segment sequence number, phase sequence, number, direction and device mark, and when the sections are connected, the adjacent section of the bus duct should be aligned, and the conductor and shell of the bus duct should not accept mechanical stress after the connection. ...

Precautions for terminal block wiring - Wiener Precautions for terminal block wiring - Wiener

1. The fastening wiring force should be moderate, avoid sliding the bolts and nuts with excessive force, and replace the bolts and nuts that have been slid in time, and prohibit the operation. 2. When tightening or loosening the screws with a screwdriver, it is necessary to force the screws to ...

Wiener bus load forecasting method Wiener bus load forecasting method

Bus load guessing is a kind of power system load guessing, and the bus system load can be defined as the sum of the terminal load of a relatively small power supply area supplied by the main transformer of the substation, which is the refinement of the system load. Bus load guessing generally only carries out short-term load guessing, and the result is ...

Wiener enclosed busbar installation Wiener enclosed busbar installation

Closed busway is a busbar system composed of metal plates (steel plates or aluminum plates) as protective shells, conductive strips, insulating materials and related accessories. It can be made into a piercing closing bus with spaced piercing junction boxes, or a feed-in closing bus without a junction box in the middle. ...

185Power - The solution for the 185mm busbar system 185Power - The solution for the 185mm busbar system

Since the launch of the 185Power system in 2014, Wiener has continued to develop new connection technologies and fuse-type disconnector technologies for the 185Power system on the basis of the 185mm bus technology. In addition to the application of 1600A below ...

Spring bracket installation steps in busbar system – Vernal Spring bracket installation steps in busbar system – Vernal

The function of the tension spring bracket in the bus system is to fix the orientation and stability of the bus duct, and it must be very careful during construction, otherwise the bus duct will fall, which will cause a very serious accident. The device step of the tension spring support in the bus system ...

Features of busway power supply system - Wiener Features of busway power supply system - Wiener

1. Trunk power distribution system, simple wiring and reliable operation. 2. It is convenient to tap, and you can tap without cutting off the main power supply. Large power supply capacity up to 6300A current-carrying capacity. 3. High dielectric strength, strong overload, superior fire performance. Good heat dissipation performance, low impedance ...

The importance of room power supply and busbar system – Vernal The importance of room power supply and busbar system – Vernal

In today's information society, the computer room is a very common equipment, so the most important thing in a computer room is the bus system, which is the center and skeleton of the power distribution of the entire computer room. Then a reasonable bus system will greatly improve the efficiency of the computer room. So how do you optimize ...

Advantages of Wiener aluminum busway Advantages of Wiener aluminum busway

1. Reliable insulation method There is an insulating layer on the conductive row, and there is a certain air yard between the phase and the phase, and there is an insulating pad block limited by DMC data between the conductive row and the shell, triple insulation, to ensure that the insulation of the bus duct is full of certainty, especially in the humid environment.

Venal common bus scheme applicable places and precautions Venal common bus scheme applicable places and precautions

When multiple inverters are used in the common DC bus, because the DC bus between the inverters is connected together, the bus energy between the inverter in the power generation operation state and the inverter in the electric operation state can flow to each other, so that the voltage of the common bus remains relatively stable, and the body ...

The busway power system is a key component - Wiener The busway power system is a key component - Wiener

The busway is one of the more critical components in the power system, and it is an important part of connecting cables to important equipment such as substations, overhead lines, transformers, circuit breakers, etc. It is widely used in various power systems, mainly for the reliable operation of power systems. ...

What is tubular busbar and dense busbar - Wiener What is tubular busbar and dense busbar - Wiener

What is a tubular busbar Tubular bus bar is a kind of bus bar product with copper tube or aluminum alloy tube as conductor and external insulation. The tubular bus has the characteristics of high current (12000A), high mechanical strength, good insulation, wide application range, etc., ...

Technical requirements for busway system – Wiener busbar Technical requirements for busway system – Wiener busbar

1. The conductor of the bus bar is a high conductivity TMY electrical hard copper bar rolled by T2 electrolytic copper, and the purity of copper must be ≥ 99.95%, and copper-aluminum alloy or other mixed alloy non-pure copper conductor materials shall not be used, and the copper plate is tin plated on the full length. 2. The raw material of the neutral wire and the phase wire in the bus system is the same.

The busway phase in the low-voltage incoming line - Wiener The busway phase in the low-voltage incoming line - Wiener

According to the requirements of the relevant specifications, the placement method of the three-phase busbar can be roughly divided into two kinds according to the model of the low-voltage distribution cabinet and the different manufacturers: the horizontal placement and the placement of the down wire.

Several faults of the Wiener bus system can be avoided Several faults of the Wiener bus system can be avoided

Cause of bus failure 1. The inner network of the bus insulator and the breaker sleeve caused by the dirty appearance 2. The voltage transformer installed on the bus and the current transformer between the bus and the circuit breaker fail 3. Reverse gate ...

How to optimize the busbar system of the computer room - Wiener How to optimize the busbar system of the computer room - Wiener

In today's information society, the computer room is a very common equipment, so the most important thing in a computer room is the bus system, which is the center and skeleton of the power distribution of the entire computer room. Then a reasonable bus system will greatly improve the efficiency of the equipment room. So how do you optimize ...

Application and technical requirements for bus protection on the low voltage side - Wiener Application and technical requirements for bus protection on the low voltage side - Wiener

1. The use status of bus maintenance on the low-voltage side According to the national standard "Code for Relay Maintenance and Automatic Equipment Design of Power Equipment" (GB50062-92): about the 3-10kV bus and the double bus running in parallel of the power plant and the primary substation, as long as the following conditions are installed.

Classification of busway – Vernal Classification of busway – Vernal

According to the different uses of the bus duct, the bus groove is generally composed of the start bus slot, the straight bus slot (without partition jacks and jacks), the L-shaped straight (horizontal) curve bus, the Z-shaped straight (horizontal) offset bus, the T-shaped straight (horizontal) tee bus, the X-shaped straight (horizontal) four-way bus, the transformer...

The main components of the Wiener bus system in the distribution cabinet are composed The main components of the Wiener bus system in the distribution cabinet are composed

(1) Busbar It is the basic element of the bus system, and there are a variety of standards, which can be installed with 5mm or 10mm thick rectangular busbar, double T type and triple T type busbar. The busbar is divided into 1-4 wires, 1 wire can be used with N or PE, 2 wires can be used together with N and PE, 3 wires are two-phase, and 4 wires can be used for three-phase ...

Busbar differential protection switching operation – Wienal Busbar differential protection switching operation – Wienal

1. Whether the maintenance scale of the bus differential is confirmed, and whether the maintenance target is unchanged Generally, differential maintenance includes bus differential maintenance, transformer differential maintenance, generator differential maintenance and line differential maintenance. The basic principle of completing differential maintenance is the same, that is, each side or each ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top