First, the reason for the fault of the induction circuit of the switch button indicator
1. Aging of circuit board: The circuit board of the switch button indicator induction circuit board may be aged if it has been used for too long, resulting in leakage in the circuit, and then the induction failure of the indicator light.
2. Damage to the sensing element: The sensing element is an important part of the indicator to feel the switching status, if the sensing element is damaged or worn, it will cause the indicator to fail.
3. Poor wiring: The wiring of the induction circuit of the switch button indicator is also a major problem, if the wiring is poor, loose or poorly connected, it may lead to the induction circuit of the induction lamp.
Second, the switch button indicator light induction circuit fault treatment plan
1. Replace the circuit board: If the circuit board of the switch button indicator sensing circuit is aging, the circuit board needs to be replaced with a new circuit board.
2. Replace the sensing element: If the sensing element is damaged, the sensing element needs to be replaced with a new component to ensure the sensing sensitivity.
3. Check the wiring: If it is a problem of poor wiring, you need to check whether the wiring is loose or poorly connected. If a wiring problem is found, the adapter needs to be reconnected or replaced.
3. Protection switch button indicator
1. Regular cleaning: The switch button indicator may be eroded by dirt and dust in daily use, so it needs to be cleaned regularly to keep it clean and tidy.
2. Moisture-proof and waterproof: The switch button indicator should be kept away from the humid environment to avoid water vapor intrusion and cause problems.
3. Check regularly: The indicator light of the switch button should be viewed regularly to ensure its normal operation.
In conclusion, when the switch button indicator presents a fault with the sensing circuit, it may be due to the aging of the circuit board, damage to the sensing element or poor wiring. When dealing with the problem, the need to find the cause of the problem first, and then take the corresponding treatment. Together, the timing protection switch button indicator can effectively extend its service life.
|
More on that
|
Tianyi switch - switching power supply failure and maintenance method
1. No output, the fuse is normal This phenomenon indicates that the switching power supply is not working or has entered the protection state. First of all, it is necessary to measure whether the starting pin of the power control chip has a starting voltage, if there is no starting voltage or the starting voltage is too low, it is necessary to check whether the starting resistance and the external components of the starting pin are ...
|
|
Tianyi switch - introduction to the types and characteristics of limit switches
Conventional domestic travel switch
LX19-001/111 in the LX19 series, LXK3-20S/T in the LXK3 series, JLXK1 series JLXK1-111/411/511 in the conventional travel switch are the most representative.
|
|
Tianyi switch - the use conditions and applicable places of low-voltage isolation switch
1. The basic conditions for the use of low-voltage isolation switches
(1) The altitude does not exceed 1000 meters;
(2) The ambient temperature is not higher than +40°C and not lower than -40°C;
(3) The relative humidity is not more than 85% (relative to +20±5°C).
2. The low-voltage isolation switch is not suitable for the following ...
|
|
Tianyi switch - the principle of electromagnetic interference generation and three control technologies of switching power supply
Generation and transmission of electromagnetic interference
There are two ways of electromagnetic interference transmission: one is conducted transmission and the other is radiated transmission. Conducted transmission is a complete circuit connection between the interference source and the sensitive equipment, and the interference signal is transmitted to the receiver along the connected circuit.
|
|
Tianyi switch button - the color meaning of the button and indicator light and the place of use
1. Buttons
1. Red
Operation in hazardous situations. It is often used for emergency stops
Stop and break. It is often used to stop all machines, stop one or more motors, stop a certain part of a piece of equipment, make the electrical components lose power, and have a stop function reset button.
...
|
|
Tianyi switch - the classification of proximity switches and their introduction
(1) Eddy current proximity switch
This type of switch is sometimes called an inductive proximity switch. It is the use of conductive objects when they are close to the proximity switch to produce eddy currents inside the object. This eddy current reacts to the proximity switch, causing the internal circuit parameters of the switch to change, so as to identify the presence or absence of ...
|
|
Tianyi switch - the term introduction of limit switches
Pre-stroke - indicates the distance or angle at which the actuator on the limit switch must move before tripping the switch contact
Operating Point - Indicates the position of the actuator when the switch contact is moved to the working position
Release Point - Indicates the position of the actuator when the contact returns to its original state
Differential - ...
|
|
Tianyi switch - the difference between high-voltage load switch and circuit breaker
1. The high-voltage load switch can be broken with load and has the function of self-extinguishing arc, but its breaking capacity is very small and limited.
2. The high-voltage isolation switch is generally not able to break with load, there is no arc extinguishing cover in the structure, and there is also an isolation switch that can break the load.
|
|
What requirements should be met by Tianyi switch - disconnector?
(1) The disconnector should have an obvious disconnection point, which is easy to identify whether the electrical appliance is disconnected from the power grid.
(2) There should be reliable insulation between the disconnect points of the disconnector, that is, there should be enough distance between the disconnect points of the disconnector to ensure that it can work reliably under harsh climatic conditions, and ...
|
|
Tianyi switch - the selection of disconnector switches
Rated voltage:
The rated voltage of the disconnector (KV) = the nominal voltage of the circuit * 1.2/1.1 times.
Rated current:
The standard value of rated current should be greater than 150% of the maximum load current.
Rated Thermal Stability Current:
Select a rated ...
|
|
VTeam switch – how to operate a linear DC power supply correctly
1) Voltage Setting: Turn on the DC switch, adjust the voltage knob to adjust the voltage reading to the desired operating power connection. If you need to lower the voltage, turn the potentiometer slowly so that the drip rate of the voltmeter is compatible with the speed of the manual adjustment knob.
2) Constant Current Setting: Connect ...
|
|
Tianyi switching power supply troubleshooting
1. Check the key points:
1) Whether the voltage at point B is 310V.
2) Whether the 15V voltage is normal.
3) Whether the voltage at point C is greater than 14V.
4) Whether the SS terminal of (8) pin IC6 is higher than 10V, whether the SD terminal of pin (10) is lower than 0.6V, and whether there is a square wave transmission at pin 13 and pin 14 ...
|
|
Tianyi switch - the switching mode of dual power transfer switch
Conversion conditions: The purpose of requiring dual power supplies is to complete the automatic and reliable conversion of dual power supplies under "specific" circumstances. This "specific condition" is the conversion premise of the dual power supply, or the conversion condition, which is the primary consideration for choosing the dual power supply.
A. In the event of a power failure ...
|
|
VTeam switch – the working principle of linear power supply
The working process of the main circuit of the linear power supply is that the input power supply is first converted into a DC power supply by the pre-regulated circuit after the initial AC voltage regulation, and then the linear adjustment element is finely adjusted under the intelligent control of the control circuit and the monolithic microprocessor controller, so that the ...
|
|
What are the common problems of Tianyi switch - disconnector?
1. What are the common faults?
Answer: The common faults of the disconnector are: (1) The contact part is overheated. (2) Porcelain insulation damage and flashover discharge. (3) Refuse to pull and close. (4) Wrong pulling and closing.
2. The overheating of the contact part of the disconnector during operation is caused by ...
|
|
Overview of limit switches and their functions - Tianyi limit switches
An overview of limit switches
Limit switch is a kind of mechanical orientation and electronic control interface, the mechanical action into electrical signals, is suitable for industrial environment of a common electromechanical and electrical components, through the contact way to detect the object, the existence and so on. It is possible to control the device's ...
|
|
The LA42V series pushbutton switch is newly launched
LA42(V) series pushbutton switch is a new series of products independently developed by the senior technical team of VTeam Electric. It can be used in applications with rated insulation voltages up to 690V and nominal ratings of A600 (AC-15) and Q600 (DC-13). LA42(V) series pushbutton switches have a beautiful appearance ...
|
|
Tianyi switch - the environmental conditions of the high-voltage load switch
1. Altitude: 2000m and below;
2. Ambient temperature: -25°C-+40°C;
3. Relative humidity: the daily average value is not more than 95%, and the monthly average value is not more than 90%;
4. Places without conductive dust, corrosive gases and water vapors;
5. No fire ...
|
|
Tianyi switch - maintenance of disconnector switch
1) Clean the dust on the surface of the porcelain, check whether the surface of the porcelain is glazed or damaged, whether there are cracks and flashover marks, and whether the iron and porcelain joints of the insulator are firm. If the damage is severe, it should be replaced;
2) Wipe the oil stains on the blades, contacts or fingers with gasoline and check the contact ...
|
|
Tianyi Button Signal Light - Color Classification of Signal Indicator and Its Meaning
(1) Green (HG, GL)
What it means: stands for Safety, Normal, Readiness (i.e., an indication under safe operating conditions or the readiness of a mechanical device to start).
Function: It is often used to indicate the state of equipment ready to start, all auxiliary components are in a state of preparation for operation, and various parts ...
|
|