Tianyi switching power supply troubleshooting

Create Date: 2024-8-30 12:03:23|Source: TIANYI/TAYEE

1. Check the key points:

1) Whether the voltage at point B is 310V.

2) Whether the 15V voltage is normal.

3) Whether the voltage at point C is greater than 14V.

4) Whether the SS terminal of pin (8) of IC6 is higher than 10V, whether the SD terminal of pin (10) is lower than 0.6V, and whether pin 13 and pin 14 have square wave output.

Through the detection of key points, the fault range can be found relatively quickly, so as to find out the faulty components, and finally eliminate the fault.

2. Common faults:

The capacitors used in this machine often have leakage phenomenon, such as C82 leakage, so that the voltage of the SS terminal of IC6 can not rise (under normal circumstances, it should rise to 10V within 10 seconds), resulting in a long time can not work after powering on; The failure of C73 causes the output signal frequency to exceed the normal operating frequency range and approach 1MHz, causing Q2 and Q6 to burn out.
Tianyi switching power supply troubleshooting

More on that
New product release of TPB1TPL1 button signal light New product release of TPB1TPL1 button signal light

TPB1 series pushbutton switch is designed by VTeam's senior R&D technical team, which is suitable for a variety of industries and various occasions. TPB1 series pushbutton switches have a complete range of colors, rich colors, economic and durable, easy installation and superior performance. Automated production, testing, and quality control are more stringent, and the products are ...

Tianyi switch - the reason why the air switch trips and cannot be pushed Tianyi switch - the reason why the air switch trips and cannot be pushed

1. What is the reason why the empty trip cannot be pushed? 1. If the air opening itself is faulty or damaged, the air opening should be replaced with a new one. 2. If the line is caused by a short circuit, the line should be found first, and then reconnected.

What requirements should be met by Tianyi switch - disconnector? What requirements should be met by Tianyi switch - disconnector?

(1) The disconnector should have an obvious disconnection point, which is easy to identify whether the electrical appliance is disconnected from the power grid. (2) There should be reliable insulation between the disconnect points of the disconnector, that is, there should be enough distance between the disconnect points of the disconnector to ensure that it can work reliably under harsh climatic conditions, and ...

Tianyi switch - the air switch is always the reason for tripping Tianyi switch - the air switch is always the reason for tripping

1. The current value of the air switch is too low, and the load power is greater than the rated power of the air switch. 2. The load joint is not firm, and the joint is not compressed. 3. If there is a short circuit in the line, check whether the electrical plug is dry. 4. The line is aging and leaking, resulting in both the live wire and the neutral line.

Tianyi switch - precautions for switching power supply to regulate current Tianyi switch - precautions for switching power supply to regulate current

1. Pay attention to stability When adjusting the output current of the switching power supply, the stability of the circuit must be ensured, otherwise there will be current fluctuations, disturbances and other phenomena, which will affect the normal operation of electronic equipment. Therefore, it is necessary to perform a ...

Tianyi switch - an introduction to the common types of low-voltage switches Tianyi switch - an introduction to the common types of low-voltage switches

1. Frame circuit breaker (universal type) - ACB: Rated current: In principle, frame circuit breakers are required for rated currents above 630A, and molded case circuit breakers are generally below 630A. It can be seen that the rated current of the frame circuit breaker is much larger, generally 630A-6300A. In addition in segments can ...

Tianyi switch - the main accessory of the air switch Tianyi switch - the main accessory of the air switch

Internal accessories Auxiliary contact: The auxiliary contact is the contact mechanically linked by the main circuit of the circuit breaker, which is mainly used for the display of the circuit breaker opening and closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, to ...

Tianyi switch - dual power supply automatic transfer switch operating procedures Tianyi switch - dual power supply automatic transfer switch operating procedures

1) When there is a power outage for any reason and the power cannot be restored in a short period of time, the backup power supply must be activated 1. Cut off the circuit breakers of the mains power supply (including the circuit breakers of the control cabinet in the distribution room, and the mains power supply cut-off of the dual power switching box), and pull the double-cast anti-reverse switch to the side of the self-provided power supply to ensure that the power supply is protected.

Tianyi switch - switching power supply failure and maintenance method Tianyi switch - switching power supply failure and maintenance method

1. No output, the fuse is normal This phenomenon indicates that the switching power supply is not working or has entered the protection state. First of all, it is necessary to measure whether the starting pin of the power control chip has a starting voltage, if there is no starting voltage or the starting voltage is too low, it is necessary to check whether the starting resistance and the external components of the starting pin are ...

The LA42V series pushbutton switch is newly launched The LA42V series pushbutton switch is newly launched

LA42(V) series pushbutton switch is a new series of products independently developed by the senior technical team of VTeam Electric. It can be used in applications with rated insulation voltages up to 690V and nominal ratings of A600 (AC-15) and Q600 (DC-13). LA42(V) series pushbutton switches have a beautiful appearance ...

Q&A on Cam Switches and Load Disconnectors (11-21) Q&A on Cam Switches and Load Disconnectors (11-21)

Q11: What is the maximum number of connecting rods for the rear mounting of P1 and P3? A: Up to 4 sections can be added, each section is 25mm. Q12: Does the P switch with SVB in the model come with PE grounding and N-wire terminals? A: P switch models with SVB are equipped with PE grounding and ...

Tianyi switch - introduction to the types and characteristics of limit switches Tianyi switch - introduction to the types and characteristics of limit switches

Conventional domestic travel switch LX19-001/111 in the LX19 series, LXK3-20S/T in the LXK3 series, JLXK1 series JLXK1-111/411/511 in the conventional travel switch are the most representative.

Tianyi switch - 9 tests and methods for switching power supply Tianyi switch - 9 tests and methods for switching power supply

1. Repeated short-circuit test ◆ Test instructions The output of the module is short-circuited in various input and output states, the module should be able to achieve protection or retraction, repeated short-circuits, and after troubleshooting, the module should be able to automatically resume normal operation. ◆ Test Method a ...

Tianyi switch - the operation method of dual power automatic transfer switch Tianyi switch - the operation method of dual power automatic transfer switch

First, first place the dual power supply on the adjustment table, and the phase wire and the neutral wire (neutral line) are docked in place, and can not be connected wrongly. Second, after the line is connected, it is necessary to check the installed line, and then turn on the main switch of the debugging station to turn on the common and standby working power supply. Three, when the double ...

Tianyi switch - the operation sequence of the disconnector switch Tianyi switch - the operation sequence of the disconnector switch

(1) First of all, when operating the isolation switch, you should first check that the circuit breaker of the corresponding circuit is indeed in the disconnected position to prevent the load from pulling and closing the isolation switch. (2) When the line is stopped and the power is transmitted, the isolation switch must be pulled and closed in order. During the power failure operation, the circuit breaker must be pulled first, and then ...

Tianyi switch - the difference between the use of cam switch and load isolation switch Tianyi switch - the difference between the use of cam switch and load isolation switch

T-cam switches and P-block switches are used in a wide range of standard circuits and currents, and the number of combinations of cam switches is virtually unlimited. Different designs, front panels and dedicated switches ensure optimum sensitivity to meet the requirements. Q1: P switch and T switch have ...

Tianyi switch - the difference between high-voltage load switch and high-voltage circuit breaker Tianyi switch - the difference between high-voltage load switch and high-voltage circuit breaker

1. The high-voltage load switch can be used as a load switch, which has the effect of self-extinguishing arc, but its breaking volume is very small and very limited. 2. The high-voltage isolation switch generally cannot be used as a load switch. There is no arc extinguishing cover in the structure, and there are also disconnectors that can switch loads on and off, but the structure is different from load switches ...

New Upgrades - A new member of the warning light family reports New Upgrades - A new member of the warning light family reports

JD series warning light is Tianyi electrical appliances in the field of signal control launched high-performance products, once launched, it has won the unanimous favor of customers, products in the design, manufacturing, quality control and other aspects of the company's quality system has always been under the strict testing and supervision of the company's quality system, to ensure that each product ...

Tianyi switch - the role of the disconnector switch Tianyi switch - the role of the disconnector switch

1. After opening, establish a reliable insulation gap to separate the equipment or line that needs to be overhauled from the power supply with an obvious disconnection point to ensure the safety of maintenance personnel and equipment. 2. According to the operation needs, change the line. 3. It can be used to divide and combine small currents in the line, ...

Tianyi switch - the allowable operating range of the disconnector Tianyi switch - the allowable operating range of the disconnector

1. Pull together the voltage transformer and lightning arrester under normal conditions. 2. Pull together the 220kV no-load bus. 3. The neutral point of the transformer when there is no ground fault in the latching grid. 4. Pull the bypass current that is closed by a switch or an isolated switch. 5. Outdoor vertical splitting triple isolation ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top