VTeam switch – how to operate a linear DC power supply correctly

Create Date: 2024-8-30 12:03:23|Source: TIANYI/TAYEE

1) Voltage Setting: Turn on the DC switch, adjust the voltage knob to adjust the voltage reading to the desired operating power connection. If you need to lower the voltage, turn the potentiometer slowly so that the drip rate of the voltmeter is compatible with the speed of the manual adjustment knob.

2) Constant Current Setting: Connect the load, then set the current regulation potentiometer to minimum, turn on the DC power, and adjust the current to the desired current value.

3) Set the voltage protection value: First adjust the voltage protection knob to the maximum value to adjust the output voltage to the desired protection value, and then slowly rotate the DC power supply voltage protection potentiometer counterclockwise until the DC power supply is too high. The voltage protection value is usually about 10% higher than the operating voltage, so adjust the output voltage to about 10% higher than the desired voltage, and then rotate the voltage protection potentiometer counterclockwise until the DC power supply is protected by overvoltage protection.

4) Set the current alarm value: First turn the current alarm knob to the maximum value to adjust the output current to the desired alarm value, and then rotate the current alarm potentiometer counterclockwise until the power is issued.

5) When the DC power supply is turned on or released from the load, the number of ammeters is immediately jumped, which is a normal phenomenon.

6) If you need to turn on the DC power again after shutting off, please wait frequently, don't switch the DC power supply frequently, the power supply is damaged.

7) If there is no output during use, check the fuse first. If the fuse blows out many times, the DC power supply may fail. At this point, stop the machine and ask a professional maintenance person to fix it.

8) The auto-trip function is configured to protect other components, and the load in the DC power supply will not be damaged. Automatic tripping during normal use means that the power supply may fail. In this case, first turn off the power and then adjust the voltage protection knob to the maximum value (do not turn the voltage regulation knob). If you're still traveling, you mean you need to fix the DC power supply.
VTeam switch – how to operate a linear DC power supply correctly

More on that
Tianyi switch - the model meaning of the proximity switch is introduced Tianyi switch - the model meaning of the proximity switch is introduced

Unmarked/Z: Inductive/inductive self-diagnosis C/CZ: Capacitive/Capacitive Self-Diagnosis N: NAMUR safety switch X: Analog F: Hall V: Reed type J: Threaded cylindrical B: Cylindrical Q: Angular cylindrical shape ...

Tianyi switch - the precautions required for the operation of dual power automatic transfer switch Tianyi switch - the precautions required for the operation of dual power automatic transfer switch

1. When closing, first of all, attention should be paid to check that the circuit breaker that can be connected to the dual-power automatic transfer switch is indeed in the opening position, and then quickly operate the risk isolation switch to close it (whether the enterprise adopts manual management agency or leveraged financial institution personnel operation), but ...

VTeam switch - introduction to the advantages and disadvantages of linear power supply VTeam switch - introduction to the advantages and disadvantages of linear power supply

Merit: Good stability: Linear power supply can provide stable output voltage and current, which is very suitable for circuits and equipment that require high power supply accuracy. Low noise: Linear power supplies have low noise, which is advantageous for applications that require a low-noise power supply. Responsiveness ...

Tianyi switch - the performance and main features of dual power automatic transfer switch Tianyi switch - the performance and main features of dual power automatic transfer switch

performance 1. Adopt double-row composite contacts, cross-connected mechanisms, micro-motor pre-energy storage and micro-electronic control technology, basically achieve zero arcing (no arc extinguishing cover); 2. Adopt reliable mechanical interlocking and electrical interlocking technology; 3. Adopt zero-crossing technology; 4、 ...

Tianyi switch - dual power supply automatic transfer switch normal working conditions Tianyi switch - dual power supply automatic transfer switch normal working conditions

1) Ambient air temperature: The upper limit of ambient air temperature is +40°C, the lower limit of ambient air temperature is -5°C, and the average value of ambient air temperature for 24h does not exceed +35°C 2) Altitude: The altitude of the installation site does not exceed 2000m. 3) Atmospheric conditions: Atmospheric relative humidity in the surrounding air ...

Tianyi switch - what is the difference between proximity switch PNP and NPN? Tianyi switch - what is the difference between proximity switch PNP and NPN?

The so-called PNP and NPN proximity switches are for the type of DC three-wire proximity switch output transistor, and even though many proximity switch output stages use MOS transistors, they are still called the same. Differences: PNP type proximity switch: The type of proximity switch output transistor is P...

Tianyi switch button - the color meaning of the button and indicator light and the place of use Tianyi switch button - the color meaning of the button and indicator light and the place of use

1. Buttons 1. Red Operation in hazardous situations. It is often used for emergency stops Stop and break. It is often used to stop all machines, stop one or more motors, stop a certain part of a piece of equipment, make the electrical components lose power, and have a stop function reset button. ...

Tianyi switch - the characteristics of low-voltage isolation switch Tianyi switch - the characteristics of low-voltage isolation switch

1. When overhauling electrical equipment, provide an electrical interval and a visible disconnection point to ensure the personal safety of maintenance personnel. 2. The disconnector can not be operated with load: it cannot be operated with rated load or large load, and it cannot be divided or combined with load current and short circuit current.

Tianyi switch - what are the functions of limit switches? Tianyi switch - what are the functions of limit switches?

1. Protection The most important role of the limit switch must be its protection effect, the limit switch is also known as the travel limit switch, which is mainly used to control the stroke of mechanical equipment and limit protection. In practice, the travel limit switch is installed in a pre-arranged position, and the travel limit switch is installed in a pre-arranged position.

Tianyi switch - the installation method of the limit switch Tianyi switch - the installation method of the limit switch

1. First open all the packages of the newly bought limit switch, confirm that the parts in each package are not missing and complete, and then discharge all the parts in turn. 2. Then open the body part of the limit switch, as long as you loosen the screws with a screwdriver.

Tianyi switch - the difference between fuse and air switch? Tianyi switch - the difference between fuse and air switch?

1. In addition to the short-circuit protection function of the fuse, the air switch can also realize the overload protection of the circuit. 2. The fuse is a one-time protection device, which must be replaced once it is blown and is very troublesome, so its reusability rate cannot be compared with the air switch. ...

Tianyi switch - the working condition of the air switch Tianyi switch - the working condition of the air switch

Ambient air temperature: upper ambient air temperature +40°C; The lower limit of ambient air temperature is -5°C; The average temperature of the ambient air for 24 hours does not exceed +35 ° C. Altitude: The altitude of the installation site does not exceed 2000m. Atmospheric conditions: Atmospheric relative humidity at ambient air temperature of +4 ...

Tianyi switch - the role of low-voltage isolation switch Tianyi switch - the role of low-voltage isolation switch

1. Through the isolation switch, it plays a good insulating role, so that the whole circuit can be safe and secure, and the maintenance personnel or staff also have enough ability to repair the circuit. 2. At the same time, the low-voltage isolation switch can also change the operation mode of the circuit, which is used in the power plant or gas plant.

Tianyi switch - the characteristics and classification of load isolation switch Tianyi switch - the characteristics and classification of load isolation switch

First, the characteristics of the load switch A load switch is a switchgear between a circuit breaker and an isolation switch. It has a simple arc extinguishing device, which can cut off the rated load current and a certain overload current, but cannot cut off the short-circuit current Second, the classification of load switches According to the operating voltage ...

Tianyi switch - precautions for switching power supply to regulate current Tianyi switch - precautions for switching power supply to regulate current

1. Pay attention to stability When adjusting the output current of the switching power supply, the stability of the circuit must be ensured, otherwise there will be current fluctuations, disturbances and other phenomena, which will affect the normal operation of electronic equipment. Therefore, it is necessary to perform a ...

Tianyi switch - introduction to the type of disconnector switch Tianyi switch - introduction to the type of disconnector switch

According to the different ways in which it is installed It can be divided into outdoor disconnector and indoor high-voltage disconnector. Outdoor disconnector refers to the disconnector that can withstand wind, rain, snow, filth, condensation, ice and heavy frost, etc., and is suitable for installation on terraces. According to the different structures of its insulating pillars ...

Tianyi switch - the principle and main purpose of transfer switch Tianyi switch - the principle and main purpose of transfer switch

1. Principle The contact system of the transfer switch consists of several moving contacts embedded in the insulated housing with a static contact base and a movable support. The moving contact is a double-break butt contact bridge, which turns the circuit on or off with the rotating shaft of the rotating shaft attached to different positions. Positioning...

Tianyi switch - the operation precautions of the disconnector switch Tianyi switch - the operation precautions of the disconnector switch

(1) Before operation, check that the circuit breaker (switch) is in the opening position accordingly to prevent the isolation switch from being pulled and closed with load. (2) There is a locking device to prevent misoperation between the knife switch, the grounding knife switch and the switch, and the reverse operation must be carried out in order. If it is locked and cannot be operated, ...

Tianyi switch - how to use the dual power transfer switch correctly Tianyi switch - how to use the dual power transfer switch correctly

1. When the power is cut off for some reason and the power supply cannot be restored in a short period of time, the backup power supply must be enabled: (1) Cut off the circuit breakers of the mains power supply (including the circuit breakers of the control cabinet of the power distribution room, and the mains power cut-off of the dual-power switching box), and pull the double-cast anti-backing switch to the side of the self-provided power supply, ...

Tianyi switch - switching power supply failure and maintenance method Tianyi switch - switching power supply failure and maintenance method

1. No output, the fuse is normal This phenomenon indicates that the switching power supply is not working or has entered the protection state. First of all, it is necessary to measure whether the starting pin of the power control chip has a starting voltage, if there is no starting voltage or the starting voltage is too low, it is necessary to check whether the starting resistance and the external components of the starting pin are ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top