Special inverter suppliers remind you that in daily industrial production, there are inverters that do not require rectifier units, which are the so-called alternating current inverters. However, the vast majority of the market is AC-DC-AC frequency converter, which also contains a rectifier unit, which is a format formed by technology and market competition to a certain extent, and the AC-DC frequency converter is less expensive to produce and more reliable and sophisticated to use, so we all use it. In practice, this is also in line with some of the rules of human scientific research.
For example, our sounds are now digitized, turned into abbreviated 0-1 codes, and then transmitted to distant places, and then turned into real sounds. Because the abbreviated things are simple to quantify and process, we will linearize the messy curves, and then use the linearized things to approximate the cluttered practical links.
AC-DC-AC inverter, is the first communication electricity into DC, and then through the IGBT chopping method inverted into communication, chopping time division processing input DC is relatively simple, because it is linear, from the calculus point of view, as long as the dividend is small enough for many squares, the cumulative effect effect is the same as the sine wave, and IGBT these devices, itself can only be turned on and off, so it is more appropriate to process the signal of the square.
Therefore, the communication has been changed to DC first, and it seems that there is an additional process, and in practice, "sharpening the knife without cutting wood", it is much simpler horizontally and vertically. Other rectifier modules and capacitors are classified as more traditional and sophisticated electronic devices, and the price is relatively cheap, but the volume is a little larger.
AC-DC inverter is relatively common and consists of three parts: rectifier, filter system and inverter. The rectifier is a diode three-phase bridge uncontrolled rectifier or a full-control rectifier composed of high-power transistors, and the inverter is a three-phase bridge circuit composed of high-power transistors.
The central filter link is to filter the voltage or current after rectification with a capacitor or reactor, and the AC-DC inverter can be divided into two types: voltage type and current type according to the different central DC filtering links, because of various factors such as control methods and hardware design, voltage inverter is widely used, and it is used in the field of industrial automation inverter (using variable voltage and frequency conversion VVVF control, etc.) and IT, power supply in the field of uninterruptible power supply (that is, UPS, using constant voltage and constant frequency CVCF control).
Of course, this is not to say that AC inverters are not developed. The matrix inverter is a new type of alternating direct inverter, consisting of nine switching arrays that are directly connected between the three-phase input and output. The matrix converter does not have a central DC link, and the output is composed of three levels, and the harmonic content is relatively small; Its power circuit is simple and compact, and can output a sinusoidal load voltage with controllable frequency, amplitude and phase; Matrix converters have a controllable input power factor and can operate in four quadrants, although matrix converters have many advantages.
However, in the process of commutation, it is not allowed to have two switches on or off at the same time, which is more difficult to achieve. The highest output voltage capability of matrix converters is low, and the high acceptance voltage of the device is also a big disadvantage of this type of converter. In addition, although it does not need a rectifier unit, it has 6 more switching devices than AC-DC inverters. |
More on that
|
The soft starter output is out of phase fault
Soft Starter Repair Problem: F 04 (Input Phase Loss):
There are several factors that cause this problem, some of which are listed below:
(1) Check whether the wiring between the incoming power supply and the motor is loose;
(2) Whether the output is connected to the load, and whether the load is matched with the motor;
(3) ...
|
|
The difference between overload and overheating of the inverter – Reynolds
The inverter is an electric control equipment that uses frequency conversion technology and microelectronic technology to control and communicate the motor by changing the power supply frequency of the motor operation. The inverter is mainly composed of rectifier (AC to DC), filtering, inverter (DC to communication), braking unit, drive unit, detection unit ...
|
|
Features of the unit tandem inverter - Reynolds
(1) The multi-pronged PWM control method is selected, and the output voltage waveform is close to the sine wave.
(2) The rectifier circuit is multiplied, the number of pulses is as high as 36, the power factor is high, and the input harmonic is small.
(3) Modular design, compact structure ...
|
|
Inverter frequency regulation fault solution - Reynolds
Most of the applications of frequency converters (hereinafter referred to as -VFDs) are primarily due to the fact that VFDs can change the output frequency and thus change the speed of the motor. If the frequency of the VFD cannot be adjusted and no damage is found on the hardware, it can be considered that the maximum output torque of the VFD is less than the load progress torque ...
|
|
Control method of Reynolds inverter
The fulfillment device commonly used in the industrial field of Reynolds inverter has good speed regulation performance and simple and convenient operation method. Therefore, it is widely used in the automation system.
Typical wiring method for the main circuit of a Reynolds frequency converter
...
|
|
The main failure mode of mechanical parts – Reynolds
The top failure modes of mechanical parts:
Failure: The mechanical part cannot complete its normal function within the planning and booking period and under the regular conditions.
Ways in which mechanical parts fail: overall cracking, plastic deformation, corrosion, abrasion, gluing, and touch exhaustion
General ...
|
|
Reynolds JJR5000 Series Soft Starter Manual
Reynolds JJR5000 series all-digital intelligent communication motor soft engine adopts power electronics skills, microprocessor skills and modern control theory skills, and is a new type of engine equipment at the current level. The product can limit the starting current of the asynchronous motor when it starts, and is widely used in electric fans, ...
|
|
Interpretation of Reynolds inverter models
Take the RNB2000 series inverter as an example.
The model number of the RNB2000 series 37kW inverter is: RNB2037-U
RN: on behalf of Reynolds;
B: low-voltage frequency conversion governor;
2: 2000 series;
...
|
|
Reynolds inverter code function description
F09 second acceleration time 0.10 - 999.9sec; 5.0sec; △** The acceleration and deceleration parameters and the second acceleration and deceleration parameters are switched by terminal X3 (see F55);
F10 second deceleration time 0.10 - 999.9sec; 5.0sec; △**Acceleration and deceleration parameters and the second acceleration and deceleration parameters are switched ...
|
|
Frequency converter soft troubleshooting – Reynolds
Undervoltage is also a problem that we often encounter in application. Mainly because the voltage of the main circuit is too low (220V series is lower than 200V, 380V series is lower than 400V), the main reason: a certain way of the rectifier bridge is damaged or there is abnormal operation in the three ways of the thyristor, which may lead to the appearance of undervoltage problems, ...
|
|
The cause of damage to the inverter brake unit - Reynolds
The inverter motor is equipped with a mechanical brake, is the inverter motor in the power generation condition when parking? Is the brake unit of the inverter working at the moment? What are the causes of brake unit damage?
Answer: 1. The inverter motor is equipped with a mechanical brake, and when parking...
|
|
The relationship between Reynolds motion control and frequency converters
Motion control has obvious period characteristics, it is a variety of high-tech generalization, used to push industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...
|
|
Characteristics of isolation transformer at the input end of AC power supply - Reynolds
a。 When the third harmonic and disturbance signals are severe, a barrier transformer can be used to eliminate the third harmonic and disturbance signals.
b。 The use of barrier transformers can generate new neutrals and avoid the abnormal operation of equipment due to defective neutrals in the grid.
...
|
|
The heat dissipation method of the switching power supply
1. Transfer heat pipes for heat dissipation.
In many applications, heat generated from the base steel plate of the power module is transferred through the heat transfer components to the distant surface of the heat pipe. In this way, the temperature of the base steel plate of the power module will be equal to the temperature of the heat pipe heat dissipation surface, the temperature of the heat transfer parts, and the temperature of the two contact ...
|
|
Analysis and repair of inverter failure cases - Reynolds
1. The inverter can not speed up the frequency increase when it starts with load
The 1366S-BR 040 inverter carries a load of 37 kW fan motors. During the trial operation, it was found that the inverter could not speed up the frequency increase normally, and the HIM display was speeding up. The inverter only swings at 1-4 Hz, and the motor emits a buzzing ...
|
|
Applicable mode of inverter maintenance - Reynolds inverter
CNC cutting machine
1. Gradual reduction method
The so-called gradual reduction method is to narrow the scope of shortcomings step by step by elaborating the shortcomings and judging the measurement parameters.
|
|
The reason why the inverter controls the motor – Reynolds
Q1: Why should I use VFD to control the motor?
When it comes to this issue, let's take a brief look at these two devices. The motor is an inductive load that hinders the change of current, and when it is started, a large change in current is generated. VFD, which is actually made up of a rectifier inverter circuit, ...
|
|
Introduction to soft starters and their relationship with frequency converters - Reynolds
When the high-power motor starts, the current is large, which will cause the grid voltage to be seriously shaken, in order to deal with this problem, the general requirements for speed regulation are not high, and the soft engine can be used to reduce the voltage and start. However, the drop in the starting current when the step-down is started will also make the starting torque drop significantly.
|
|
Precautions for the coordination of PLC and inverter - Reynolds
Under the current production conditions, when the inverter is used to form an automatic control system for control, in many cases, it is necessary to choose PLC and inverter to match the use, such as bearing cleaning, packaging paper printing, PCB board production, etc.
PLC ...
|
|
The external configuration of the inverter is solved - Reynolds
With the improvement of the degree of automation of packaging machinery, packaging machine inverter (hereinafter referred to as VFD) plays an increasingly important role in packaging machinery. Capsule filling machine, high-speed tablet press, bottling production line, aluminum-plastic packaging machine, cartoning machine, each equipment will use VFD, mainly ...
|
|