Features and performance of Rosemount pressure sensors
Features and performance of Rosemount pressure sensors
1. Diffusion silicon pressure sensor
The working principle of the diffusion silicon pressure sensor is that the pressure of the measured medium acts directly on the diaphragm of the sensor (stainless steel or ceramic), so that the diaphragm produces a micro-displacement proportional to the pressure of the medium, ...
|
|
The Rosemount flow meter indicates the cause of the failure
During the long-term use of the Rosemount flowmeter, there may be some problems in the manual: 1. The manual is not accurate for a long time; 2. There are always no signs; 3. It means that the fluctuation range is large and there is no reading; 4. The indication does not return to zero; 5. There is no indication when the flow rate is small; 6. When the large flow indicates that the positive ...
|
|
The difference between a Rosemount transmitter and a Siemens transmitter
The difference between Siemens' transmitter and Rosemount's transmitter: Siemens' transmitter is a piezoresistive pressure transmitter, and Rosemount's transmitter is a capacitive pressure transmitter.
The transmitter converts the output signal of the sensor into a signal that can be recognized by the controller.
|
|
What factors affect the performance of the Rosemount 3051 differential pressure transmitter?
1. Effect of temperature
Rosemount differential pressure transmitters will vary greatly in process temperature, ambient temperature, and will certainly differ from the reference conditions when the transmitter is tested, which also means that the functionality will be different from the reference accuracy presented. Temperature on differential pressure transmitters ...
|
|
How to care for your Rosemount pressure transmitter after use
Eight ways to use Rosemount pressure transmitters:
1. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer tube (coil), and the working temperature of the Rosemount transmitter should not exceed the limit.
2. When wiring, pass the cable through the waterproof joint or wrap it around.
|
|
Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter
1. The upstream and downstream pipe diameter of the flowmeter on the installation point must be installed in accordance with the standard flowmeter caliber, otherwise the measurement accuracy will be affected.
2. If there is a tapering pipe in the upstream of the flowmeter installation point, there should be a straight pipe section of equal diameter of not less than 15D (D is the diameter of the pipe) in the upstream of the flowmeter, and there should be ...
|
|
Rosemount differential pressure transmitter selection considerations
The following points should be considered in the selection of differential pressure transmitters:
1. Measure the scale, the accuracy of the demand and the measurement function;
2. Measure the environment of the outer surface, such as the industrial environment of petrochemical industry, the existence of flammable, toxic and explosive risk atmosphere, and the high ambient temperature;
3 tested ...
|
|
What are the features of the Rosemount 644 temperature transmitter?
1. It can greatly reduce the cost of wire and labor.
2. The advanced diagnosis function can reduce the number of on-site repairs.
3. Order a complete temperature transmitter and temperature sensing assembly to simplify setup, specifications, and ordering, and then reduce costs.
4. Adopt HART communication protocol. ...
|
|
What to do if the Rosemount pressure transmitter measurement is inaccurate
Common Rosemount pressure transmitter measurement incorrect situations:
1. The input impedance of the Rosemount transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A)Ω if necessary, if it does not match, corresponding measures can be adopted according to its differences: such as increasing the power supply ...
|
|
A method for verifying a current loop signal for a Rosemount pressure transmitter
The Rosemount pressure transmitter uses a 4-20mA signal, which is the conversion value of the output generated by the pressure transmitter. The output of the transmitter is detected according to the HART protocol, however, it is converted to a proportional current so that it can be visualized as a reading. Normally, at zero level output, the transmitter displays 4mA ...
|
|
Eight ways to maintain your Rosemount 3051 pressure transmitter
1. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer tube (coil), and the working temperature of the Rosemount transmitter should not exceed the limit.
2. When wiring, pass the cable through the waterproof joint or winding pipe and tighten the sealing nut to prevent rain from leaking through the cable.
|
|
How to choose the Rosemount 3051DP differential pressure transmitter
1.3051D transmitter is a coplanar pressure transmitter, which can measure the pressure or the side differential pressure, and there are two options P is the differential pressure measurement and G is the gauge pressure.
2. To understand the range used in the field, select the corresponding code according to the range, a total of 5 options: the lowest - 6.216KPA and the maximum 13789.54KPA.
...
|
|
What are the features of the Rosemount 644 temperature transmitter
The Rosemount 644 temperature transmitter is widely used in industrial temperature measurement, and the quality is also very stable, the following is to tell you about the characteristics of the 644 temperature transmitter:
1. It can greatly reduce the cost of wire and labor.
2. Advanced diagnostic function can reduce the need for on-site repairs.
|
|
The Rosemount 3051 transmitter is prone to some failures
1. The pressure of the 3051 transmitter does not go up to the output of the transmitter, the output of the pressurized transmitter does not change, and the output of the pressure transmitter changes suddenly, and the zero position of the pressure relief transmitter cannot be returned.
In this case, you should see if the pressure interface is leaking or blocked, and after looking at the wiring method and power supply, ...
|
|
Summary of problems in the use of the Rosemount 3051 transmitter
1. What kind of output signal does the Rosemount transmitter need to obtain: mV, V, mA and frequency output digital output, and the choice of what kind of output depends on a variety of factors, including the separation between the Rosemount transmitter and the system controller or display, whether there is "noise" or other electronic interference signals.
|
|
Rosemount transmitters are affected by the angle of inclination of the installation
The actual working performance of the Rosemount transmitter will be affected by the angle of inclination, ambient temperature, static pressure and fluid temperature of the device.
|
|
How the Rosemount transmitter is wired
During the use of the Rosemount transmitter, wire the Rosemount transmitter according to the following steps:
1. Take out the Rosemount 3051 and remove the electronic enclosure marked "FIELD TERMINALS".
2. Will be positive ...
|
|
How to solve the problem of Rosemount differential pressure transmitter migration failure
The migration of differential pressure transmitters is a form of application, which refers to the process of artificially moving the measuring point of a differential pressure transmitter from the zero point to the required value. The migration of differential pressure transmitters includes two major contents: positive migration and negative migration.
|
|
The installation environment affects the use of Rosemount transmitters
If you want to get better measurement results in practical applications, you need to pay attention to the following environmental issues when installing:
1. The Rosemount transmitter pressure impulse pipe should be arranged in a place where the temperature fluctuation is small, and the buffer tube (disk) should be connected when measuring steam or other low-temperature medium.
|
|
What causes inaccurate measurements in Rosemount pressure transmitters
Rosemount Pressure Transmitter Inaccurate Measurement Causes:
1. Whether the power supply of the Rosemount pressure transmitter is normal, if it is less than 12VDC, you should check whether there is a large load in the circuit, and the input impedance of the transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A...
|