(1) General bus duct

Non-flame retardant and non-fire-resistant bus duct selected for general load power distribution. In the event of a short circuit, it will be incinerated until it is connected to other busbars, which can easily cause fire accidents.

                              Classification of the use of busway in different places - Vernal

(2) Flame retardant bus duct

In the event of a fire, the flame of this section of the bus will not spread to the bus duct of the other section. To put it simply, the coating of the metal shell of the busway and the insulation material of the busbar must be flame retardant.

(3) Refractory busway

A busway that maintains the integrity of the circuit at regular times under flame conditions. The insulation material of the fire-resistant bus duct is usually non-combustible material, and flame retardant material is also selected. However, it is necessary to carry out type tests according to the national standard JB/T10327-2011 "Refractory Bus Trunk System (Refractory Bus Trunk System)" to verify its electrical functions such as fire prevention and fire resistance functions, and ensure that it can supply power normally within the specified time in the fire environment.

More on that
How to choose the right fuse - Wiener How to choose the right fuse - Wiener

1. Select the type of fuse according to the line requirements and installation conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses. ...

Avoidable failures in busbar systems – Wienal Avoidable failures in busbar systems – Wienal

Cause of bus failure 1. The internal network of bus insulators and breaker sleeves caused by surface pollution 2. The voltage transformer installed on the bus and the current transformer between the bus and the circuit breaker are faulty 3. The support of the circuit breaker or isolation switch caused by the reverse operation ...

Phase of the busway in the low-voltage incoming line – Wiener Phase of the busway in the low-voltage incoming line – Wiener

According to the requirements of the relevant specifications, the placement of the three-phase busbar can be roughly divided into two kinds according to the model of the low-voltage distribution cabinet and the different manufacturers: horizontal placement and placement of the down wire, according to the order of placement.

Advantages of busbar mounted electrical equipment - Wiener Advantages of busbar mounted electrical equipment - Wiener

The novelty, flexibility and originality of the busbar device appliance. It indicates the vitality of this skill and its broad market prospects. This is the real reason for our attention. First of all, this small electrical appliance plant was conceived ...

Considerations for purchasing a busbar system – Wiener Considerations for purchasing a busbar system – Wiener

The bus system plays a very important role in the practice of construction, and for products such as the bus system, the relevant items can not be ignored, so that we can better use the practical value of this type of product. Generally speaking, when we are purchasing a bus system ...

Wiener is a common way to wiring busbars Wiener is a common way to wiring busbars

Single bus wiring method: all outgoing wires are connected to the same busbar, which is also the most cost-effective and simplest wiring method Single bus segmentation: The outgoing line is arranged in two parts on different sections of the single busbar, so that a power failure in the meantime does not affect the power supply of the other bus ...

The advantage of busway over cable in modern construction - Wiener The advantage of busway over cable in modern construction - Wiener

The power supply trunk of modern buildings plays a very important role like the aorta of the human body, and if something goes wrong, it can cause serious consequences. In the 80s of the 20th century, many stable cables were used in modern buildings. With the rapid development of the city, the power load of the building ...

Features of busway power supply system - Wiener Features of busway power supply system - Wiener

1. Trunk power distribution system, simple wiring and reliable operation. 2. It is convenient to tap, and you can tap without cutting off the main power supply. Large power supply capacity up to 6300A current-carrying capacity. 3. High dielectric strength, strong overload, superior fire performance. Good heat dissipation performance, low impedance ...

Fuse selection method - Wiener busbar Fuse selection method - Wiener busbar

1. Select the model of the fuse according to the circuit requirements and device conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses. ...

Differences and differences between busway and other busbars Differences and differences between busway and other busbars

The busbar and busway are actually one open and one closed, and the other is not closed. The closed busway is referred to as the busway, that is, the busway is sealed The closure of the busbar, the closure of the busbar and the busway all refer to the same east...

The role of plug-in busway – Wiener The role of plug-in busway – Wiener

Generally speaking, plug-in busway is mainly used for power transmission. We know that all conductors will have losses, and the losses caused by the flow of electricity through conductors are larger and some are smaller. For example, compared with the aluminum wire with the same wire diameter and the copper wire, the loss of aluminum is larger, and the loss of copper is smaller. That is, the conductivity ...

Advantages of installing cable trays with busway – Wiener Advantages of installing cable trays with busway – Wiener

When it comes to cable tray installation, wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plug-in bus duct, fireproof bridge is the way it uses plugged in.

Strip Switch vs. Disconnector Circuit Breaker Comparison – Wiener Strip Switch vs. Disconnector Circuit Breaker Comparison – Wiener

Bar switches are different from regular switches. They are critical to ensuring effectiveness. For example, when the current exceeds a certain amount of time, they cause heat to be generated, allowing the fuse to switch the fuse to further assist in breaking the circuit. Therefore, as a kind of current protection device, they can achieve ...

Busbar system reverse operation – Wiener Busbar system reverse operation – Wiener

(1) For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...

Distribution cabinet bus calculation method - Vilna Distribution cabinet bus calculation method - Vilna

1. The main bus at the upper end of the low-voltage distribution cabinet is calculated according to the material and cross-section in the extension meter. The bus bar connected to the main bus at the upper end of the switch is not accounted for and is included in the low-voltage distribution cabinet. 2. The transformer mainly depends on how large the load is, according to your switchgear can be calculated to match the transformer, but not the same...

Uses and technologies of cable junction boxes – Wienal Uses and technologies of cable junction boxes – Wienal

XBT series mine flameproof communication cable distribution box has the characteristics of small size, reasonable cable import and export, and wide coverage. Each distribution box has 4-10 inlet and outlet bells, which is suitable for HUYV type mine signal cable in coal containing sexual gas (methane) mixture (non-mining face).

Busway Installation Specification – Wiener Busway Installation Specification – Wiener

1: The basic requirements for the bus duct: 1) Conductor data: high-purity electrical copper drawn from national standard T2 electrolytic copper, with a purity of more than 99.9% and a full-length tinned copper conductor. 2) Shell: Select high-quality aluminum-magnesium alloy profiles that meet the strength, with heat dissipation ribs, and the appearance should be oxygen-proof.

The essence of Wiener busbar technology The essence of Wiener busbar technology

1. Closed busbar hooking technology Circuit breakers and contactors can be hooked on the bus through the bus adapter, and fuse switches and other products are directly attached to the bus, so the bus bar plays a two-layer effect of conductive and fixed rotation.

The application of Wiener bus system wiring technology in box transformer The application of Wiener bus system wiring technology in box transformer

The bus system is to directly connect the components to the bus, the bus does not need to be perforated, at this time, the bus is not only the conductor of the component, but also the support of the component, the current can reach 2500A, so that the box transformer function has the following progress: 1 ...

There are several main ways to wiring the Wiener bus There are several main ways to wiring the Wiener bus

Bus line refers to a product made of copper (copper bar) and aluminum material with high conductivity to transmit electrical energy and have the ability to collect and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the output of the generator, transformer or rectifier ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top