Precautions for the use of Delta inverters

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

1. The inverter must be selected correctly.

2. Read the product manual carefully, and wiring, device and application in accordance with the requirements of the manual.

3. The inverter device should be firmly grounded to suppress radio frequency disturbance and avoid electric shock caused by leakage of the inverter.

4. When the speed of the motor is controlled by the inverter, the temperature rise and noise of the motor will be higher than that of the grid power (power frequency); When working at low speed, due to the low speed of the motor blades, attention should be paid to ventilation and cooling and appropriate load reduction to prevent the temperature rise of the motor from exceeding the promised value.

5. The impedance of the power supply line should not be too small. When the capacity of the distribution transformer is greater than 500KVA or the capacity of the distribution transformer is greater than 10 times the capacity of the inverter, or when the inverter is connected to the distribution transformer very closely, due to the small impedance of the circuit, a large surge will occur on the inverter instantaneously, which will damage the rectifier elements of the inverter. When the line impedance is too small, a communication reactor should be installed between the power grid and the inverter.

                            Precautions for the use of Delta inverters

6. When the three-phase voltage unbalance rate of the power grid is greater than 3%, the peak value of the input current of the inverter is very large, which will form the inverter and connect to overheat or damage the electronic components, and the communication reactor needs to be installed. In particular, when the transformer is V-shaped, it is more severe, and in addition to installing a reactor on the communication side, it is also necessary to install a DC reactor on the DC side.

7. Do not install too large capacitors on the incoming side because of the improvement of power factor, nor can you install capacitors between the motor and the inverter, otherwise the line impedance will decrease, and the inverter will be damaged by overcurrent

8. The outlet side of the inverter can not be connected in parallel to compensate the capacitor, nor can the capacitor be paralleled in order to reduce the high-order harmonics of the output voltage of the inverter, otherwise the inverter may be damaged, in order to reduce the harmonics. Able to connect reactors in series.

9. The start and stop of the motor with frequency converter speed regulation cannot be directly operated by circuit breaker and contactor, but the control terminal of frequency converter should be used to operate, otherwise the frequency converter will be out of control, and may form severe consequences

10. It is generally not advisable to install a communication contactor between the inverter and the motor, so as to avoid overvoltage and damage to the inverter between the current breaks. If additional installation is required, the output contactor should be closed before the inverter is operated.

11. For the occasion when the inverter drives the ordinary motor for constant torque operation, it should be avoided to run at low speed for a long time, otherwise the heat dissipation effect of the motor will become worse and the heating will be severe. If it is necessary to run for a long time at low speed and constant torque, it is necessary to choose a variable frequency motor.

More on that
Delta servo problem analysis Delta servo problem analysis

1: What is the difference between servo motor and general motor? The biggest difference between servo motors and general motors is the motor rotor and reaction equipment. The surface of the servo motor rotor is pasted with a strong magnetic plate, so that the magnetic field generated by the stator coil can control the orientation of the rotor, and the acceleration and deceleration characteristics are ...

Important parameters of Delta inverters Important parameters of Delta inverters

The inverter is the pioneering work of Delta Automation, and it is also the largest selling product of Delta Automation. In the highly competitive market, Delta inverters have always maintained a strong growth momentum and made great achievements in the high-end product market and the economic product market. Delta continues to launch high-end products ...

Identify the problem area of the inverter - Delta Identify the problem area of the inverter - Delta

In the process of inverter protection and maintenance, various problems are often encountered, such as field line problems, poor primary parameter settings or mechanical equipment shortcomings. If there is a defect in the inverter, how to distinguish which part of the problem is a little more detailed here. ...

The cause of inverter heating - Delta inverter The cause of inverter heating - Delta inverter

1. The problem of the inverter and the motor itself If the motor has been used for a long time, it is not good to clean the insulation function, or the bearing may be stuck, and it may show a large current and heat. The coupling between the motor and the load may also be worn, or the motor is unbalanced, the fixtures of the motor are loose, etc.

Delta's inverter adjusts the motor speed mode Delta's inverter adjusts the motor speed mode

The speed control on Delta's inverter is mainly as follows: 1. Adjust the variable resistance directly from the surface of the Delta inverter 2. External analogue voltage or current signal to adjust 3. Take advantage of the multi-function of the inverter ...

Voltage regulator selection method - Delta inverter Voltage regulator selection method - Delta inverter

1. Capacity safety factor The AC regulated power supply is based on the output apparent power (kVA) as the nominal rated capacity, and the load is not purely resistive under normal circumstances, that is, the power factor COS¢≠1, and the active power that the regulator can output in practice kW = capacity (kVA) × COS¢. So in the real ...

Mitsubishi's MHIET energy storage system, Delta, helped to solve the problem Mitsubishi's MHIET energy storage system, Delta, helped to solve the problem

Battery Management Solution Factory - Delta released the Mitsubishi Heavy Industries Group's star product, Mitsubishi Heavy Industries Group's three-power transformer hybrid one-power transformer system, proposing a high-quality method. This power transformer system is currently used at Mitsubishi Electric Manufacturing Plant in Aihara City, Kanagawa Prefecture, Japan.

Comparison of three speed regulation methods for Delta DC motors Comparison of three speed regulation methods for Delta DC motors

There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation. 1. Armature loop string resistance The applied resistor is connected into the armature circuit to achieve the purpose of speed regulation. Speed Direction: Add ...

A number of Delta's new high-end power supply products were unveiled at CMEF A number of Delta's new high-end power supply products were unveiled at CMEF

Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places! CDQ1F Active ...

Far EasTone telecommunications, delta and Microsoft jointly work together to build a 5g intelligent factory Far EasTone telecommunications, delta and Microsoft jointly work together to build a 5g intelligent factory

Far EasTone Telecommunications, Delta Electronics, and Microsoft Corporation in Taiwan, China, announced today 8 that the three parties will work together to build a 5G smart workshop. With the characteristics of "big things" (network big data, artificial intelligence technology, Internet of Things technology), combined with 5G80MHz continuous network bandwidth, the integration of servo independent innovation and intelligence ...

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud platforms are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

Detection methods for Delta circuit breakers, AC contactors and frequency converters Detection methods for Delta circuit breakers, AC contactors and frequency converters

1. Circuit breaker A circuit breaker is a device that can be manually or automatically controlled, and is used to control the on/off of the system power supply in the equipment circuit system. When there is a suspicion that there is a defect in the electrical system of the equipment, the primary functional part of the power supply should be checked. Under normal circumstances, when in the ON state, the input input ...

Misunderstandings of power-saving and energy-saving use of inverters Misunderstandings of power-saving and energy-saving use of inverters

Industrial control automation products inverters are depicted as power-saving, energy-saving control automation products, therefore, many people will think that as long as the equipment is installed with inverters, it will be able to save energy, but this is not the case. The inverter of industrial automation products itself produces energy-saving ...

Delta servo system composition Delta servo system composition

The servo system is mainly composed of a servo controller, a drive circuit, a servo motor and the corresponding reaction testing equipment. (1) Servo motor Servo motor refers to the motor that controls the mechanical components in the servo system, and the servo motor has an encoder inside, which can respond to the movement in real time.

Delta inverter fault alarm code and solution Delta inverter fault alarm code and solution

The OCC AC motor driver detects an unusual overcurrent surge on the output side See if the motor extra matches the communication motor drive extra Check whether there is a short circuit between the communication motor driver U-V-W View...

Common knowledge points of Delta inverters Common knowledge points of Delta inverters

1. How to set the acceleration and deceleration time of Delta inverter? Solution(s): The acceleration time of Delta's inverter is the time it takes for the driver to accelerate from 0.0Hz to "high operating frequency". Deceleration time refers to the deceleration time required for the inverter to decelerate from "high operating frequency" to 0.00Hz.

Inverter encoder role - Delta Inverter encoder role - Delta

In the case of low speed accuracy requirements or small load changes, the inverter can be selected. The U/f control method refers to the method of controlling the frequency and voltage of the inverter. The rotational speed change in this control method is done by changing the set value of the frequency. ...

New and old models of Delta drives New and old models of Delta drives

Delta's VFD series of inverters has established a wide brand awareness in the industrial automation market. Each series of products is designed for different operation needs such as torque, loss, overload, overspeed work, etc., and is adjusted according to different industrial machinery attributes; It can provide customers with the most diversified choices ...

Delta UPS power supply RT5K extension configuration method for 2 hours Delta UPS power supply RT5K extension configuration method for 2 hours

Engined DC: 1K=36V, 2K=72V, 3K=96V, 5K, 6K, 10K=192V UPS power supply accounting formula: 1KVA (volt-ampere) =700W (watt) =1000VA (volt) UPS power supply x extended time + starting DC = how big the battery is Start DC + V number of battery = how much power is distributed ...

Delta inverter repair steps Delta inverter repair steps

Delta inverters still have a certain influence in the industry, but even if the reputation is good, it will inevitably show some failures. Let's take a look. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top