How to use a PC to control Delta's inverter

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

Problem Description:

How does Delta inverter use a PC to control it?

                               How to use a PC to control Delta's inverter

Solution(s):

The communication interface of Delta's inverter is to use RS485 with the ModBus communication pattern commonly used in the industry to do the material handing, so as long as the general ModBus software is used, the driver can be read and written using a PC.

In addition, for program developers, Delta also provides DLL files for ModBus to facilitate the writing and development of programs (DLL files can be downloaded from the download area and the program controller software can be downloaded to download the Delta Modbus communication library).

With the software developed with the above DLL files, the internal parameters of the drive can be directly set, monitored and controlled.

Ex: The communication of the driver is set to (preset: station number 1, ASCII mode), then the driver is issued ":010620000002D7\x0D\x0A" through ModBus, and the driver will start working. ":010620000001D7\x0D\x0A", the drive will stop working. 01 is the station number, 06 is the function code (write), and 2000H is the internal scratchpad of the drive.

More on that
Analysis of misunderstandings in the application of Delta inverters Analysis of misunderstandings in the application of Delta inverters

The capacity selection of the inverter is based on the rated power of the motor Myth: The capacity selection of the inverter is based on the rated power of the motor Compared with the motor, the price of the frequency converter is the most expensive, so under the premise of ensuring safe and reliable operation, the frequency conversion can be reasonably reduced.

The principle, composition and function of Delta's inverter The principle, composition and function of Delta's inverter

1. What is a Delta inverter? Delta inverter is a device that converts the power supply (50Hz or 60Hz) into a communication power supply of various frequencies to realize the variable speed operation of the motor.

Productivity maintenance tips for Delta drives Productivity maintenance tips for Delta drives

1. When the Delta inverter breaks down in the future, it is best not to hand it over to someone who has no experience in repairing the inverter to repair the inverter, otherwise it may get worse and worse. Sometimes it's about to fuse, be sure to check whether there is a problem with the module, some electricians have not experienced it, and immediately install a good fast melt (definitely not ...

PLC Peripherals – Delta PLC PLC Peripherals – Delta PLC

Programming equipment: simple programmer, most only accept mnemonic programming, and some can also be programmed graphically (such as Japan's Toshiba EX programmable controller). The cluttered one has a graphical programmer, which can be programmed in the trapezoidal language. Some also have dedicated computers that can be used for other ...

The reason for the low voltage trip of the inverter - Delta The reason for the low voltage trip of the inverter - Delta

The low voltage of the inverter mainly refers to the low voltage of the central DC circuit, and the reasons for the low voltage of the central DC circuit generally come from two aspects: ​ (1) Low voltage from the input side of the power supply The power supply under normal conditions ...

The importance of harmonic control - Delta inverter The importance of harmonic control - Delta inverter

With the rapid development of the electronic and electrical industries, the demand for magnetic materials has promoted the world's huge industrial clusters. In the process of producing magnetic materials, many manufacturers are facing a great dilemma: the production of magnetic materials is mainly controlled by thyristor rectifier furnaces such as bell furnaces and nitrogen rotary furnaces.

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

The reason for the slow response after the frequency converter potentiometer adjusts the frequency - Delta The reason for the slow response after the frequency converter potentiometer adjusts the frequency - Delta

The external use resistor is an external operation form of the inverter, which controls the inverter through the external operation signal generated by the external starting switch and frequency setting potentiometer. The regular external voltage signal of different inverters is different. ...

Analysis and correction of the cause of Delta servo drive alarm Analysis and correction of the cause of Delta servo drive alarm

Analyze and correct the cause of Delta servo drive alarms.   Control current and undervoltage protection. Alert Number: 11. Reason: The voltage at the end of the dynamic DC bus is lower than the specified value. Due to the instantaneous shortage of power supply capacity, the control voltage is too low. Measure: Measure the DC bus ...

Delta's inverter fault warning solution Delta's inverter fault warning solution

Product series: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ Fault Codes: noCL Fault clarification: The lack of oil is correct Solution: 1. Check the fuel level of the fuel tank 2. Check whether there is any leakage on the oil road.

DC motor speed regulation method - Delta DC motor speed regulation method - Delta

There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation. 1. Armature loop string resistance The applied resistor is connected to the armature circuit.

The parameter that needs to be set for the inverter - Delta The parameter that needs to be set for the inverter - Delta

There will be some difference between the parameter setting of the inverter at the factory and the requirements of practical application. Therefore, the reasonable setting of the inverter parameters is directly related to whether the inverter can be used normally, which is of decisive significance. General-purpose inverters generally have dozens or even hundreds of functional parameters.

Delta's C2000 inverter has evolved completely Delta's C2000 inverter has evolved completely

For those who are familiar with Delta's automation, they know that Delta's inverters have two main series: "M300" and "C2000". "Compact Inverter M300 Series": This series has been introduced many times before, including MS300 (standard general-purpose type), MH300 (high power ...

The technical advantages of the three-axis positioner - Delta The technical advantages of the three-axis positioner - Delta

1. The welding station is actively handed over, and the operator has been loading and unloading parts in a fixed position, which effectively reduces the labor and logistics intensity of the operator, and the welding products of the whole set of equipment have strong compatibility and strong automatic welding scalability. 2. All ...

Mitsubishi's MHIET energy storage system, Delta, helped to solve the problem Mitsubishi's MHIET energy storage system, Delta, helped to solve the problem

Battery Management Solution Factory - Delta released the Mitsubishi Heavy Industries Group's star product, Mitsubishi Heavy Industries Group's three-power transformer hybrid one-power transformer system, proposing a high-quality method. This power transformer system is currently used at Mitsubishi Electric Manufacturing Plant in Aihara City, Kanagawa Prefecture, Japan.

Precautions for the operation of Delta servo motors Precautions for the operation of Delta servo motors

1) The AC servo motor works by means of a dedicated drive. Do not connect the commercial power supply (100/200V, 50/60Hz) directly to the line of the servo motor, otherwise the servo motor will not work properly and the servo motor will be permanently damaged. ...

The reason for the shaking of the inverter for the motor - Delta The reason for the shaking of the inverter for the motor - Delta

When using the motor dragged by the inverter, sometimes the motor flutters and the over-fire flutter may burn out the motor and cause immeasurable losses. So what is the reason for this phenomenon? 1. The motor is damaged ...

Basic conditions for Delta UPS uninterruptible power supply Basic conditions for Delta UPS uninterruptible power supply

1. Visually inspect the UPS and battery (or other energy storage) equipment for obstacles, and properly cool the surrounding area. 2. Ensure that there is no abnormal operation or positive warning on the UPS panel, such as: overload or overdischarge of the battery close to it. 3. Check if there is battery corrosion or other shortcomings ...

Selection of braking resistors for Delta inverters Selection of braking resistors for Delta inverters

1. The necessity of braking resistance If the regenerative energy that occurs during deceleration and descent in the application is too large, there is a possibility that the voltage of the main circuit inside the inverter will rise, causing damage. Because usually the inverter has a built-in overvoltage maintenance function, the main circuit overvoltage (O...

Delta NT series UPS industrial power supply Delta NT series UPS industrial power supply

Delta's NT series UPS is a high-power UPS carefully discussed by experts for large-scale users, and a number of advanced skills have been selected, which can be used for various data processing systems, telecommunications systems, satellite systems, network systems, medical equipment, safety and emergency escape equipment, monitoring and security systems, and various industrial systems.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top