1. TWR (Time Write) command
Instructions to write time presets to the built-in real-time clock: Clock information is written to the TWR (Time Write) command. The sequence number of the action instruction is FNC167, [S ·] T, C and D can be used, and only 16-bit operations can be used, accounting for 5 program steps.
The function of this command is to write the time preset value to the built-in real-time clock, and the written information is put to [S ·] in advance. In the initial 7 modules, when the command is executed, the built-in real-time clock is immediately changed to apply a new time.
2. TRD(FNC166) TRD(P) instruction
TRD(FNC166) TRD(P) instructions are 16-bit operations and occupy 7 program steps. T, C and D are available.
The purpose of this instruction is to read the information from the built-in instant clock and put it into the preliminary 7 words by [D.].
The time loading instruction, i.e., loading from the system software together with the data register, and the system software together with the data register for the real-time clock, is D8013-D8019, in which the time, date, hour, minute, second and its worship are matched.
Time writing instruction, that is, according to the PLC, the information of the people's calibration is written into the system software together with the register, and the TWR instruction is applied.
Calibrate the clock
Usually the internal clock of the new PLC is wrong, and it is necessary for people to upgrade to the Internet clock, which can be changed according to the program anytime and anywhere.
Another way
After communicating with the PLC connection on the computer, click the "Online" button in the status bar and select the clock setting.
|
More on that
|
Mitsubishi PLC controls the servo motor through a touch screen
The Mitsubishi PLCFX3U-48MT-ES-A is used as the control element, and the Mitsubishi touch screen GT1155-QFBD-C is used as the operating element to directly control the specific program design of the Mitsubishi servo motor.
First, the selection of components in the control system
1. Selection of PLC
In the application of Mitsubishi servo drive ...
|
|
The wiring steps of the input and output circuits of the Mitsubishi PLC
The wiring diagram steps of the input and output circuit of Mitsubishi PLC, there are generally three types in the wiring diagram of the input and output of the PLC, one is DC 12-24V input, and there is output, so what about the external input?
(1 ...
|
|
Mitsubishi inverter capacity and capacity selection
The capacity (non-functional) of the Mitsubishi inverter for the drive motor can be understood from the change in energy flow determined by the operation method.
1. When accelerating or operating at constant speed
The efficiency of the inverter is the output current, that is, ...
|
|
Manipulator Fault Repair - Mitsubishi Robot
1. Speak before you start
With regard to defective electrical equipment, it is necessary not to rush to start, but to inquire about the passage and defective phenomena that cause defects. For unfamiliar equipment, you should also understand the circuit principle and structural characteristics, and follow the corresponding rules. Before dismantling, it is necessary to fully understand each electrical department ...
|
|
Explanation of Mitsubishi pIc source type and drain type
The source type is the power supply of the device, which has an input drive source and an output point with a power supply; Drain type means that the device does not have its own power supply, and the drive of the input point requires an external power supply, and the output is only a passive contact signal.
The general input points are ...
|
|
What are the main factors of interference in Mitsubishi PLC system?
(1) Radiative dry disturbance from space
The radiated electromagnetic field (EMI) in space is mainly caused by power networks, transient processes of electrical equipment, lightning, radio broadcasting, television, radar, frequency induction heating equipment, etc., generally known as radiation disturbance, and its dispersion is extremely chaotic. ...
|
|
Mitsubishi inverter FR-D700 series selection
Q: When will I choose the D740 series inverter?
A: D700 is a multi-function compact inverter, more portable, less than E700, the general function can be basically realized, simple start and stop can use D700 series.
Q: How should Mitsubishi inverter D740 ...
|
|
Mitsubishi plays an important role in the paper industry
From raw material pulp to papermaking, and then through packaging and logistics, the paper towel finally completes the "transformation" to meet customers. The impression of packaging and quality, coupled with the comprehensive effect of multiple specifications, traceability, high standards, authoritative certification and other factors, will finally win the hearts of customers, and then establish a trustworthy ...
|
|
Mitsubishi garbage incinerator equipment with a daily processing capacity of 1,500 tons was delivered and put into operation
Mitsubishi Heavy Industries Environmental & Chemical Engineering Co., Ltd. (MHIEC, President: Takayuki Hishinuma, Headquarters: Nishi-ku, Yokohama), a subsidiary of the Mitsubishi Heavy Industries Group, has supplied two advanced Mitsubishi grate furnaces to a large-scale waste-fired power plant in Xiaogan City, Hubei Province, China. The waste-fired power generation ...
|
|
Mitsubishi servo system selection
Mitsubishi servo system mainly has MR-J4, MR-JE, MR-JE-AS and other series, MR-J2S, MR-J3, MR-ES has been discontinued, gradually withdrawn from the shopping mall, the first three are considered.
When selecting a Mitsubishi servo, the first thing is to choose the MR-J4 series or MR-JE series according to the application, and the driver uses the A-type ...
|
|
Mitsubishi PLC program lost backup program write method
The reasons for the loss of the PLC program are the lack of battery power supply for the user's saved program, the internal circuit of the PC, the motherboard burned out due to the impact of external high voltage such as lightning strikes, etc., which will be encountered in our PLC control system. For example, the old type of plc such as the FX2N series, which has been discontinued...
|
|
Mitsubishi PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment and sensors and drive equipment, which is the low-level network of the entire network system. The CC-Link fieldbus connection is selected, and the number of wiring is greatly reduced, and the system maintainability is improved. Whereas...
|
|
Mitsubishi tension controller principle
1. Tension Manipulator Principle - Introduction
The tension manipulator can be called the tension manipulator, which is usually used with magnetic particle brake, magnetic particle clutch and tension detector, and is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the human ability to ...
|
|
Motor speed control through PLC control inverter - Mitsubishi
1. Press the motor start button, and the motor will start and run at the corresponding speed of 5Hz; After the delay of 10s, the motor will run at the speed corresponding to 10Hz, and after the delay of 10s, the motor will continue to speed up and run at the speed corresponding to 20Hz; In the future, every 10s, the speed law changes, a ...
|
|
Introduction to the Mitsubishi FX PLC Outage Service
1. What is suspension?
The so-called suspension refers to the fact that in the process of sequentially performing the program scanning, when there is a request to respond immediately, the scanning work performed at that time is immediately suspended, and the service work specified in the request is performed first. When the service job is complete, go back to ...
|
|
Introduction to Mitsubishi PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. The CC-Link fieldbus connection greatly reduces the number of wirings and improves the maintainability of the system. Whereas...
|
|
Mitsubishi servo motor alarm code and processing skills
1. Mitsubishi servo drive alarm code AL31.1
Fault analysis: It is the motor overspeed alarm.
Cause analysis: 1. The frequency of a single pulse of the input command is too high;
2. The acceleration and deceleration time is too small, resulting in overshoot and too large;
3. Mitsubishi servo system is unstable;
4. Electricity ...
|
|
Mitsubishi low-power Z024 series inverter failure OC cause
(1) Aging of the drive circuit
Due to the use of a long period of time, it will inevitably lead to the aging of components, which will cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm will often appear as soon as it is running.
( ...
|
|
The role of Mitsubishi inverters
1. Overvoltage maintenance
The output of the motor inverter has the function of voltage detection, and the inverter can actively adjust the output voltage so that the motor does not bear the overvoltage. Even if the output voltage adjustment fails and the output voltage exceeds 110% of the normal voltage, the inverter will stop to maintain the motor.
|
|
Mitsubishi Electric appeared at the 2021 China Smart Expo
From August 23 to 25, 2021, the 2021 China International Intelligent Industry Expo (hereinafter referred to as the Smart Expo) was held in Chongqing International Expo Center. Mitsubishi Electric (China) ...
|
|