1. Tension Manipulator Principle - Introduction
The tension manipulator can be called the tension manipulator, which is usually used with magnetic particle brake, magnetic particle clutch and tension detector, and is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the artificial ability to give a certain output to the actuator through the tension manipulator; Some tension manipulators also have the function of calculating the diameter of the winding, which is generally used in the winding equipment, and is divided into unwinding and rewinding; In addition, there is a taper adjustment function, which can directly set some of the required take-up taper in the process inside the controller.
2. Tension Manipulator Principle - Advantages
The tension manipulator adopts a number of advanced technologies in the world; Dedicated microprocessor, high-speed 18-bit A/D converter, switching power supply, anti-interference automatic recovery technology, and PID no overshoot algorithm, LX-005TD tension controller is fully digital design, so it has the characteristics of high measurement and control accuracy, strong anti-interference, complete functions, and simple operation.
3. Tension manipulator principle
The tension manipulator is a kind of appearance of controlling this kind of tension, the tension manipulator is a system developed by a single-chip microcomputer or some embedded equipment and peripheral circuits, it is a kind of control appearance, it can directly set the tension value required to be controlled, and then directly input the signal of the tension sensor as the tension response value, after comparing the error, input to the PID and other controllers for processing, * good output to the peripheral actuator to control, * finally achieve the intention of small error * and fast system response.
4. Tension Manipulator Principle - Use
The tension controller can adopt inlay, wall-mounted, floor-mounted device method advanced technology, excellence, manufacturing high-precision electromagnetic/magnetic powder clutch/brake, LEESUN manual/automatic tension controller. Due to the company's strict requirements for quality and moderate price, the products have been widely used in packaging machinery, printing machinery, wire and cable machinery, paper-making machinery, plastic machinery, food machinery, textile machinery, glass machinery, woodworking machinery, electronic machinery and other equipment industries.
|
More on that
|
Mitsubishi inverter control mode
According to the classification of the main circuit operation mode, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter;
According to the classification of operating principles, it can be divided into V/f control frequency conversion ...
|
|
The matching relationship between the inverter and the motor - Mitsubishi
It has become an irreversible trend to drive the motor through the inverter, and in the actual application process, because the matching relationship between the inverter and the motor is not very reasonable, it often leads to some problems. When selecting an inverter, you should fully understand the load characteristics of the equipment driven by the inverter. Ms. Ginseng ...
|
|
Mitsubishi FX5U series PLC ten advantages
1. CPU function
As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB.
2. Built-in analog input and output (alarm output by the way)
Built-in 12-bit 2-channel analog input ...
|
|
Performance comparison of Mitsubishi servo motors
First, the control accuracy is different
The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors are also smaller in some functions according to the segmentation. Such as Sanyo ...
|
|
Mitsubishi causes electromagnetic interference
1. Harmonic disturbance
The rectifier circuit will generate a harmonic current, which will cause a voltage drop on the impedance of the power supply system, resulting in a distortion of the voltage wavepattern, and this distorted voltage will cause disturbance to many electronic devices (because most electronic devices can only operate in the sine wave).
|
|
The Mitsubishi QnUDVCPU module records the write function of the settings
The models of QnUDVCPU series products are Q03UDVCPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, and Q26UDVCPU.
Data logging settings can be written to the target memory of the Mitsubishi QnUDVCPU module. When writing data recording settings, you should write data in the purpose of the writing settings.
|
|
Mitsubishi Electric develops MEMS LiDAR solutions for autonomous vehicles
TOKYO, March 12, 2020 - Mitsubishi Electric Corporation (TSE: 6503) today announced that it has developed a compact Light Detection and Ranging (LiDAR) solution that integrates microelectromechanical systems (MEMS) that enable ultra-wide horizontal scanning angles in the self-...
|
|
Mitsubishi PLC's six programming languages
(1) Ladder diagram
Programming language is traditionally called a ladder diagram. The ladder diagram follows the method of relay control circuit, and it can also be said that the ladder programming language is simplified from the symbol evolution on the basis of the logic control of relays and contactors commonly used in electrical control systems.
|
|
Mitsubishi Electric instruction format
(1) Arbitrary axis AC command (G140)
G140 Instruction Address = Axis Address Instruction Address = Axis Address ... ;
Command Address: Arbitrary Axis AC Command (G140) After that, specify the 1-character address set by the parameter (#12071-#12078) to be used for moving commands, etc.
|
|
Ground leakage current of Mitsubishi inverter and countermeasures thereof
There is electrostatic capacitance between the input and output wiring of Mitsubishi inverters and other wires, between the ground and the motor, and there is a leakage current flow. The leakage current value is affected by factors such as electrostatic capacitance and carrier frequency, and the leakage current is high when the carrier frequency of the inverter is set high and the leakage current is operated under low noise conditions.
|
|
Advantages of Mitsubishi inverter installation reactor
Features of the output reactor:
1. It is suitable for reactive power compensation and harmonic management
2. The primary effect of the output reactor is to compensate for the influence of long-line distributed capacitance, and output harmonic current according to the press; 3. Effectively maintain Mitsubishi inverters and improve the power factor, which can thwart the ...
|
|
Mitsubishi Electric begins research and development of a Mars satellite probe probe
TOKYO, February 21, 2020 – Mitsubishi Electric Corporation (TOKYO:6503) announced today that it has been appointed by the Japan Aeronautics and Astronautics Agency (JAXA) as the contractor for the Mars Lunar Probe (MMX) space probe. Mitsubishi Electric has launched development activities for the project that will utilize MMX's system ...
|
|
Capacitive action in Mitsubishi inverters
Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many titles, the following introduces the meaning of some commonly used titles.
...
|
|
An introduction to the types of data inside the Mitsubishi FX series
A lot of data is used in the internal structure of the PLC and in the user's use program. These data have the following forms in terms of structure or number system.
(1) Decimal number
Decimal numbers are also known as word data in PLC. It is first and foremost ...
|
|
Mitsubishi PLC's method of controlling the inverter
1. Mitsubishi PLC's analog signal control inverter
Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...
|
|
Mitsubishi PLC programming cable communication port setting method
1. Plug the programming cable into the USB port of the computer.
2. On the desktop, place the mouse on the "My Computer" icon, and then right-click.
3. In the pop-up menu, select "Device Manager".
...
|
|
The difference between Mitsubishi PLC source type and leak type
Mitsubishi PLC split source type (PNP) or drain type (NPN), here are their differences
1: Leakage logic: When the current flows out of the signal input terminal, the signal becomes ON, which is leakage logic. The current flows through the terminals and has the output characteristics of an NPN transistor.
2: Source logic: When ...
|
|
Mitsubishi inverter control method
There are several ways to classify Mitsubishi inverters:
According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter;
Depend on...
|
|
Mitsubishi catalogue of some small PLC models and commonly used touch screens
Commonly used touch screen model description
Economical touch screen GS2107-WTBD 7 inch widescreen, 800*480, 65535 colors, USB/232/422/Ethernet, DC
Pass through...
|
|
The GOT widescreen family has been expanded with the GT2512
When industrial automation enters the era of artificial intelligence. Human-computer interaction has long surpassed the simple control of machines, and has been upgraded to obtain more information, use more functions and new skills for more accurate and efficient control, and complete the intelligent manufacturing promotion of industrial automation.
...
|
|