Mitsubishi PLC network structure

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment and sensors and drive equipment, which is the low-level network of the entire network system. The CC-Link fieldbus connection is selected, and the number of wiring is greatly reduced, and the system maintainability is improved. Moreover, not only the data of the switching quantity such as ON/OFF, but also the intelligent equipment such as ID system, barcode reader, inverter, man-machine interface, etc., can be realized from the communication of various data to the handling of terminal production information, and the collection and management of the machine operation status has greatly improved the efficiency of maintenance and maintenance. When used in Q series PLCs, CC-Link has better functions and is more concise to use.

                                 Mitsubishi PLC network structure

2. The control layer/MELSECNET/10 (H) is the middle layer of the entire network system, which is a convenient and high-speed control network for processing data exchange between PLC, CNC and other control equipment. MELSECNET/10, as a MELSEC control network, has won high market reviews for its outstanding real-time performance, simple network settings, program-free network data sharing concept, and redundant loops, and the number of devices selected has reached the highest level in Japan and is rare in the world. MELSECNET/H not only inherits the excellent features of MELSECNET/10, but also makes the network more real-time and has a larger data capacity, which further adapts to the needs of the market.

3. The information layer/Ethernet (Ethernet) information layer is the highest level in the network system, which is mainly used to transmit production management information, quality management information and equipment working conditions between PLC, equipment controller and production management PC, and the information layer uses the most common Ethernet. It can not only connect to Windows PC, UNIX workstation, etc., but also to various FA devices. The Ethernet module of the Q series PLC series has become more and more popular as an e-mail transmission and receiving function on the Internet, so that users can easily send and receive production information e-mails anywhere in the world, and build a long-distance monitoring and management system. Together, using the FTP server function of the Internet and the MELSEC protocol, it is possible to easily upload/download programs and transfer information.

In addition, in addition to the above-mentioned networks, Q series PLC can also support the networks of other manufacturers such as Profibus, Modbus, Devicenet, ASi, etc., and can also carry out serial communication such as RS-232/RS-422/RS-485, and carry out data transmission and other communication methods through data dedicated lines and telephone lines.

When communicating in Mitsubishi's PLC network, there is no sense of difference in network type and continuity, and long-distance monitoring, correction, and debugging of data communication and programs can be carried out across networks, regardless of the level and type of network. MELSECNET/H and CC-Link use a cyclic communication method to send and receive messages automatically and periodically, without the need for a special data communication program, only a simple parameter setting. MELSECNET/H and CC-Link use the broadcast method to send and receive circular communication, so that the data on the network can be shared together. For Ethernet, MELSECNET/H, CC-Link networks used in Q Series PLCs, network parameters and various functions can be set on the GXDeveloper software screen, which is simple and convenient.
More on that
Mitsubishi inverter setting parameter adjustment method Mitsubishi inverter setting parameter adjustment method

Mitsubishi inverter has many setting parameters, each parameter has a certain selection scale, and the inverter can not work normally due to improper setting of a single parameter in the application. Let's take a look at the Mitsubishi inverter parameter setting operation. ...

Mitsubishi PLC advantages Mitsubishi PLC advantages

Discrete control and motion control, Mitsubishi's instructions are abundant, there are dedicated positioning instructions, control servo and stepping are easy to complete, to complete some messy action control is also Mitsubishi's strength, and Siemens is weaker in this area, there is no special instruction, do servo or step positioning control is not ...

Advantages of Mitsubishi inverter installation reactor Advantages of Mitsubishi inverter installation reactor

Features of the output reactor: 1. It is suitable for reactive power compensation and harmonic management 2. The primary effect of the output reactor is to compensate for the influence of long-line distributed capacitance, and output harmonic current according to the press; 3. Effectively maintain Mitsubishi inverters and improve the power factor, which can thwart the ...

Mitsubishi Electric develops MEMS LiDAR solutions for autonomous vehicles Mitsubishi Electric develops MEMS LiDAR solutions for autonomous vehicles

TOKYO, March 12, 2020 - Mitsubishi Electric Corporation (TSE: 6503) today announced that it has developed a compact Light Detection and Ranging (LiDAR) solution that integrates microelectromechanical systems (MEMS) that enable ultra-wide horizontal scanning angles in the self-...

Mitsubishi participated in the 4th CIIE to introduce the E-JIT green induction solution Mitsubishi participated in the 4th CIIE to introduce the E-JIT green induction solution

On November 5, 2021, the 4th China International Import Expo was grandly held at the National Convention and Exhibition Center in Shanghai. At the 4th CIIE, Mitsubishi Electric's booth was located in Hall 4.1 of the Technical Equipment Zone of the Convention and Exhibition Center, with an exhibition space of 400 square meters. At Mitsubishi Electric's booth, the high-profile event was ...

The method of Mitsubishi PLC to control the Mitsubishi inverter The method of Mitsubishi PLC to control the Mitsubishi inverter

The switching quantity control inverter of PLC is selected (that is, the switching output terminal of PLC is directly connected to the switching input terminal of the inverter, and the PLC can control the start, stop, forward and reverse rotation of the inverter and high, medium and low speed multi-stage speed operation through the program). ...

Advantages and disadvantages of different output types of Mitsubishi PLC Advantages and disadvantages of different output types of Mitsubishi PLC

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The biggest advantage is that it is accustomed to high-frequency action, and the echo moment is short, generally about 0.2ms, but it ...

Malfunction caused by capacitance between PLC input lines – Mitsubishi Malfunction caused by capacitance between PLC input lines – Mitsubishi

There is a capacitance between the wires of the cable, and a qualified cable can limit this capacitance to a certain size. It is a qualified cable, when the cable length exceeds a certain length, the capacitance value between the lines will also exceed the required value, when the cable is used for PLC input, the capacitance between the lines will be ...

Mitsubishi inverter pre-use debugging method Mitsubishi inverter pre-use debugging method

1. No-load energizing test of Mitsubishi inverter. 1. Ground the ground terminal of the Mitsubishi inverter. 2 Connect the power input terminal of the Mitsubishi inverter to the power supply through the leakage maintenance switch. 3 Check whether the factory display window of the Mitsubishi inverter is normal, if it is not correct.

How to deal with Mitsubishi PLC failures How to deal with Mitsubishi PLC failures

01. Base system problem In Mitsubishi PLC, there are binary, octal, decimal, 10, 2-10 (BCD), etc., we need to master the conversion of 2-8 base. 2-8, remember the binary number from the back, divide every 3 into a group, and each group is converted into octal respectively, such as 1 ...

The Mitsubishi PLC FX2N is connected to a computer through the group Taiwang The Mitsubishi PLC FX2N is connected to a computer through the group Taiwang

In the PLC control system, the content that needs to be displayed mainly includes timer value, counter value and data register value, and the data display method can be summarized into two fundamental types: one is based on the PLC data communication interface, such as RS-232, RS-485/422, and the display device also has such an interface.

Mitsubishi PLC's six programming languages Mitsubishi PLC's six programming languages

(1) Ladder diagram Programming language is traditionally called a ladder diagram. The ladder diagram follows the method of relay control circuit, and it can also be said that the ladder programming language is simplified from the symbol evolution on the basis of the logic control of relays and contactors commonly used in electrical control systems.

Functional characteristics of Mitsubishi's various series of servo motors Functional characteristics of Mitsubishi's various series of servo motors

Mitsubishi servo motor system series: MR-J2S series, MR-J3 series, MR-ES series, MR-E series. Mitsubishi servo motor MR-J2S series 1. The product also has RS-232 and RS-422 serial communication functions, which can be used by a personal computer equipped with servo setting software.

Programming element for Mitsubishi FX2N series PLCs Programming element for Mitsubishi FX2N series PLCs

Each element of the Mitsubishi FX2N series PLC is indicated by a characteristic letter, such as X indicates the input relay, Y indicates the output relay, M indicates the auxiliary relay, T indicates the timer, C indicates the condition element, etc., and these elements have a specified number. ...

Introduction to Mitsubishi PLCFX3U positioning control Introduction to Mitsubishi PLCFX3U positioning control

1. The workbench runs in the direction of the decrease of the value of the current value register (generally M8342=OFF in the opposite direction), and when it encounters the near-point signal, it becomes a creeping speed, and the zero-point signal after leaving the near-point signal arrives with a delay of 1ms, and the pulse output is immediately aborted. ...

Power factors affecting Mitsubishi inverters Power factors affecting Mitsubishi inverters

The speed regulation of Mitsubishi inverter power regulator is adopted, one is to regulate the speed according to the requirements, and the other is to save energy. It is based on the following elements: 1) The frequency conversion speed regulation system has low loss and high operating power. 2) The motor is always kept running at a low slip rate, which reduces the rotor loss.

Performance comparison of Mitsubishi servo motors Performance comparison of Mitsubishi servo motors

First, the control accuracy is different The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors are also smaller in some functions according to the segmentation. Such as Sanyo ...

Mitsubishi inverter forward and reverse parameter adjustment Mitsubishi inverter forward and reverse parameter adjustment

For the first time to use Mitsubishi inverter, the operation command and frequency command equipment may not be familiar, especially related to the setting of domestic inverter, the two parameters are separated. Mitsubishi's, on the other hand, are collectively referred to as the form of operation. ...

Mitsubishi PLC has a built-in time adjustment step Mitsubishi PLC has a built-in time adjustment step

1. TWR (Time Write) command Instructions to write time presets to the built-in real-time clock: Clock information is written to the TWR (Time Write) command. The sequence number of the action instruction is FNC167, [S ·] T, C and D can be used, and only 16-bit operations can be used, accounting for 5 program steps. The work of the directive ...

Seven-step method for PLC project debugging - Mitsubishi PLC Seven-step method for PLC project debugging - Mitsubishi PLC

Many novices in the electrical industry are not sure how to start debugging after completing the planning links such as electrical control cabinets and PLC programs. Perhaps some people due to inappropriate debugging methods have led to PLC burning and other problems, so how should the planned electrical system be debugged? Follow these seven steps. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top