From June 12 to June 16, 2023, Pilz will be present at the THERMPROCESS trade fair in Düsseldorf, Germany, at booth B10 in Hall 9.
Germany Thermprocess Düsseldorf is the most important trade fair for industrial furnaces and heat treatment in Germany and the most important industrial furnace exhibition in Europe. At the same time, Germany Dusseldorf Foundry Exhibition GIFA, Germany Dusseldorf Metallurgical Die Casting Exhibition METEC, Germany Dusseldorf Precision Casting Exhibition NEWCAST, four exhibitions combined, basically the world's well-known large-scale enterprises will be present to release new products.
The total area of the last exhibition of Thermprocess in Dusseldorf, Germany was 30,000 square meters, and 345 exhibitors were from China, Korea, Japan, United States, United Kingdom, Australia, Spain, Brazil, Singapore, Dubai, Turkey, etc., with 56,000 exhibitors.
Thermprocess Germany Düsseldorf is the international trade fair for thermal process technology and one of the world's leading trade fairs for industrial furnaces and heat treatment production processes. The main focus is on stoves and heat treatment equipment, refractory and insulated stove components and machinery, as well as measurement and control technology and data.
At this trade fair and seminar, Pilz will be presenting its own burner management system and demonstrating how to control and monitor burners that comply with the standards. Whether it's the configurable safe small controller PNOZmulti 2 or in large-scale projects, the automation system PSS 4000 can be used as a burner control system for burner management applications.
|
More on that
|
Peel magnetic relays – the difference between solid state relays and mechanical relays
1. The structure/working principle of the two is different
Mechanical relays consist of an iron core, coils, and contacts. When the coil is energized, the current in the coil generates a magnetic field that makes the contacts act, thus completing the working principle of the mechanical relay.
Solid state relays are made up entirely of electronic components. That...
|
|
Introduction to the principle and application of Pilz ground proximity switches
The Pilz safety proximity switch also belongs to a position sensor with a switching output, its measuring head is usually a plate that constitutes a capacitor, and the other plate is the object itself, when the object moves towards the proximity switch, the dielectric constant of the object and the proximity switch changes, so that ...
|
|
Peel magnetic relays - an introduction to the classification of relays and their functions
1. The role of intermediate relays
It plays the role of converting and transmitting control signals, that is to say, its input signal is the energizing and power-off signal of the coil, and the output signal is the contact action of the intermediate relay. Essentially, it is a type of voltage relay ...
|
|
Pierz switches – what are the properties of safety switches?
The safety switch prevents personnel from entering the hazardous area until all safety conditions have been met
Provide bolt switches, safety magnetic switches, safety door lock switches, safety rope pull switches, emergency stop buttons, twisted chain interlocking switches, safety enable switches, safety limit switches, explosion-proof open...
|
|
REASONS FOR USE OF PILZ SAFETY RELAYS
Why can't ordinary relays be used in safety-related applications?
Ordinary relays use the mechanical action of coils and metal contacts to switch loads. Metal contacts may be fusion welded due to repeated operations. Once this happens, the machine will also be ...
|
|
Introduction and benefits of Pilmagnetic security locks
The use of safety locks If there are hazards in the equipment, such as moving levers, rotating mechanisms or even robots, in order to avoid damage to the operator, a safety gate system will be added to the protective cover (door). Safety door interlocking devices are widely used in the field of industrial safety. ...
|
|
A new product from Pilz is coming soon: the FSoE master module for PNOZmulti 2
PNOZ m EF EtherCAT FSoE is a forthcoming safety bus communication module from Pilz that supports the FSoE (FailSafe over EtherCAT) protocol. As a new member of the PNOZ multi 2 family, the module can be used as an FSoE master with a maximum cycle time of 10 ms ...
|
|
Pilz safety switches – how to install safety switches
1) The installation of the switch panel should be after the installation of the lamp, and the switch must be connected in series on the live line; Application of sealed or protected sockets in wet locations; The allowable deviation of the verticality of the panel is not more than 1mm; The gap between the panels installed in rows should not be greater than 1mm.
2) Where the socket must be facing the switch panel ...
|
|
Peel magnetic relay - the application and current situation analysis of solid state relays
Applications for Solid State Relays
(1) The recommended value of the foreign SSR trigger signal (i.e., the current through the light-emitting tube) is 10mA DC, and the recommended value of the domestic SSR trigger signal is 12-25mA DC.
(2) Multiple SSRs can use the same trigger signal, which is common in the control of three-phase AC loads.
|
|
Pilz: Three levels of security validation, tailored to the user
Pilz's safety validation services for plants and machines can now be customised to suit your needs, choosing between three different validation levels. This guarantees an efficient service tailored to individual requirements, allowing plants and machines to be designed in accordance with standards and with maximum safety.
In the wind ...
|
|
Steps for using Pilz safety relays
Pilz safety relays consist of several relays and circuits to compensate for each other's abnormal defects and achieve the full functionality of a relay with low misoperation or even correct relays. The lower the fault value and fault, the higher the safety factor. In order to prevent unavoidable misoperation or natural wear and tear of the machine, it should also be ...
|
|
Pilz safety light barriers provide safety for applications that require physical protection
Pilz safety light curtains provide cost-effective safety for applications that require body protection. The safety light curtains have a wide operating range of up to 55 m and are ideally suited for the demarcation of external areas. Whether the user wants a single beam or a multi-beam encoder, in the PSENopt and PSENopt II series, there is a choice of 2 ...
|
|
Pilz: Designing safe railway sites
From hardware components to complete safety concepts: Pilz has extended its industrial expertise from the field of machinery safety and health and safety regulations to railway sites. With many years of knowledge and experience, Pilz has demonstrated the same competence in the railway industry as it does in an industrial environment.
Skin...
|
|
How do I remove the Pilz safety relay on the circuit board?
1. The mount can be quickly replaced.
2. For low-value and easy-to-purchase multi-leg assemblies, destructive removal methods can be employed to prevent board stepping on. For this type of relay, use pliers to break it off and then use a set with a semicircular or triangular file.
|
|
Pierre Servo Amplifier - Introduction to the advantages of servo amplifiers
Single-phase servo amplifier (referred to as amplifier), with a variety of quarter-turn, linear stroke, multi-turn single-phase electric actuator (electric actuator) matching, widely used in industrial automation control process in the automatic adjustment system, this amplifier is an improvement of the traditional amplifier, compared with the traditional ...
|
|
Pilz: The first products with IO-Link Safety will soon be available on the market
IO-Link is an open sensor communication protocol that represents a powerful and standardized (IEC 61131-9) connection technology in the field of point-to-point communication and is fieldbus and system independent. The communication protocol will also be used for functionally safe data exchange in the near future.
The advantages of IO-Link are ...
|
|
Pilz conducts brake tests on freight trains
The technology and business of rail freight have remained the same for decades. Until now, in order to test the brakes of freight trains, the crew would walk around the entire train and hit each axle with a special hammer to check the proper operation of the braking system. Rail transport systems in Austria ...
|
|
Peel magnetic relays – features of relay modules
1. The same module can be triggered by high or low level through different wiring, and the trigger current is not less than 1mA, and the output capacity of the IO port of some 51 single-chip microcomputers is weak, and the circuit of pulling up or increasing the driving capacity is required (the default is low level triggering);
2. Advantages of low-level drive, ...
|
|
Pilz: A new version is here! This time it's more powerful
Since its launch, Pilz's flagship product, the configurable and safe small controller PNOZmulti, has been impressed by users for its robustness, flexibility and ease of operation.
PNOZmulti Configurator as a configuration tool for the safe small controller PNOZmulti ...
|
|
Peel magnetic relay - how to adjust the voltage of high and low voltage relays?
1. Determine the voltage range that needs to be regulated: First of all, you must clarify the voltage range you need to regulate, as well as the specifications of the high and low voltage relays and the voltage range that can be adjusted. If there is no clear scope and specifications, you can check the relevant manuals of high and low voltage relays or consult the equipment manufacturer.
|
|