The cause of the broken shaft of the motor - LS generates electricity

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

1. Improper device:

The motor is not concentrious with the equipment being dragged, resulting in excessive radial load on the motor, which eventually leads to metal exhaustion. When the radial load on the extension end of the motor shaft is too large, it will cause the motor shaft to have zigzag deformation in the radial direction. When the motor rotates, the shaft is deformed by torsion in all directions, which eventually causes the motor shaft to break, and the cracking location is generally close to the bearing. Regarding the selection of the motor with pulley connection, but when some customers match the pulley to the motor output shaft, because the pulley is too heavy or the belt device is too tight, it will cause the motor to continue to be subjected to the effect of variable stress during the operation of the motor, and the maximum bending moment of this stress on the shaft is near the fulcrum of the output shaft bearing, and the repeated impact causes fatigue, so that the shaft gradually cracks, and finally completely cracks.

                              The cause of the broken shaft of the motor - LS generates electricity

2. Excessive vibration of equipment and motor during operation:

If the motor is not fixed firmly, such as running on the frame, the whole base is unstable, and it shakes during operation, resulting in the unstable pull of the motor belt, and the damage to the shaft when the tension is large.

3. Other reasons:

The load is momentarily too large; Small horse-drawn carts, motor shafts are in a state of exhaustion for a long time; External collisions will also cause shaft breakage, which is a relatively messy problem, and the motor device and other problems can be checked from time to time during use to prevent problems.

More on that
Inverter failure and solution - power generation Inverter failure and solution - power generation

1. HW problem This problem may be a fault unique to LG-IG5 series inverters, and the main causes are as follows: (1) Damage to the cooling fan. Due to the use of environmental and other factors, the friction of the fan bearing is too large, causing the fan load to be too large and showing H ...

Introduction to inverter self-learning motor - LS power generation Introduction to inverter self-learning motor - LS power generation

1. What is a self-learning motor of inverter? Enter the motor nameplate (voltage, current, Hz rating) in the inverter parameters, and then the inverter actively measures other parameters of the motor. Second, why should the inverter learn by itself?

LS inverter frequency conversion mode LS inverter frequency conversion mode

1. The operator panel is given The operator panel is a simple frequency setting method of the inverter, and the user can directly change the set rate of the inverter through the potentiometer, digital key or rising and descending keys on the inverter operator panel. The big advantage of the operator panel is that it is simple ...

Precautions for the selection of peripheral equipment for LS power inverter Precautions for the selection of peripheral equipment for LS power inverter

The peripheral equipment of the inverter mainly includes cables, contactors, air switches, reactors, filters, braking resistors, etc. Whether the selection of the peripheral equipment of the inverter is correct and suitable also directly affects the normal operation of the inverter and the service life of the inverter.

What are the categories of PLC products? What are the categories of PLC products?

The XGT series is a creative PLC product family that combines LS's power generation technology capabilities to provide next-generation solutions based on open networks, ultra-high-speed processing speeds, compact scales, and greatly improved software for the engineering environment. XGT series for a variety of ...

Introduction to the working principle of LS electric molded case circuit breaker Introduction to the working principle of LS electric molded case circuit breaker

Molded case circuit breakers are also known as equipment circuit breakers, all parts are sealed in plastic housings, auxiliary contacts, undervoltage trippers and shunt trippers are modular. Because of the very compact structure, the molded case circuit breaker is basically impossible to maintain. It is mostly manually operated, and the large capacity ...

Features of LS SUSOL series circuit breakers Features of LS SUSOL series circuit breakers

Features of SUSOL series circuit breakers: It can be used as the main switch of electrical equipment, and the limit breaking ability is high, Icu=Ics Modular construction of circuit breakers: Tripper replacement (TS series) can be combined in a variety of combinations, such as ...

The advantages of the inverter in practical application - LS power generation The advantages of the inverter in practical application - LS power generation

With the continuous progress of industrial automation, inverters have also been widely used, energy conservation and environmental protection as the core of China's industrial economy, in the direction of the sustainable development of China's industry, but also useful to promote the sustainable development of China's inverter profession, so that I ...

Automatic adjustment of motor parameters - LS power generation Automatic adjustment of motor parameters - LS power generation

Step 1: If the motor can be completely separated from the load, in the case of a power failure, the motor is mechanically separated from the load, and the motor is allowed to rotate freely without load. Step 2: After powering on, select the VFD command source (F0-04) as the command channel of the operation panel. ...

Precautions for the coordination of inverter and PLC - LS produces electricity Precautions for the coordination of inverter and PLC - LS produces electricity

As an alternative to traditional relays, PLC is widely used in various fields of industrial control. Because the PLC can be used to change the control process with software, and has the characteristics of small size, sensitive assembly, simple programming, strong anti-disturbance ability and high reliability, it is especially suitable for operation in harsh environments. ...

Summer maintenance and maintenance of inverter method - LS power generation Summer maintenance and maintenance of inverter method - LS power generation

1. Check the running status of the inverter, whether the voltage and current value during operation are within the normal range. 2. Carefully monitor and record the ambient temperature of the frequency conversion chamber, which is generally between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C. 3. Prevent ...

The cause of motor burnout caused by inverter - LS generates electricity The cause of motor burnout caused by inverter - LS generates electricity

In fact, the problems of the motor are not the cause of the motor itself, most of them are caused by the non-standard debugging of the inverter or the wrong inverter motor when the inverter motor is used, etc., mainly due to the following situations: 1. Put the general motor ...

Selection of AC contactors in the field of building electrical - LS power production Selection of AC contactors in the field of building electrical - LS power production

1. The series and parallel connection application of contactors Many electrical equipment are single-phase loads, so several poles of multi-pole contactors can be used in parallel. Such as resistance furnaces, welding transformers, etc. When using several poles in parallel, a smaller capacity contactor can be used. However, it must be noted that after parallel ...

DC motor troubleshooting - LS power generation DC motor troubleshooting - LS power generation

1. The speed of the motor slows down, and the cause of the problem of sound disorder may occur in the electronic speed stabilization device and the motor itself. If there is no problem with the power supply, most of the motor itself has a problem. It can be repaired by replacing the new motor and dismantling and repairing the motor. Dismantling and repairing the motor ...

Models and features of LS Metasol series products Models and features of LS Metasol series products

Metasol series MS (100A and below) products are newly launched and the primary product specifications: contactors, thermal relays, and center relays. Features: The body is small, the internal structure is sealed, and the safety factor is high ...

The matrix alternating control mode of the inverter - LS power generation The matrix alternating control mode of the inverter - LS power generation

VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. One of the disadvantages is that the input power factor is low, the harmonic current is large, the DC circuit needs a large energy storage capacitor, and the regenerative energy cannot be reflected back to the grid, that is, it cannot carry out four-quadrant operation.

Fatal failure of LS power terminal block Fatal failure of LS power terminal block

From the point of view of application, the function that should be reached is: it is necessary to conduct the local area where the touch part should be conducted, and the touch is reliable. If the insulating part should not be conducted, it is necessary to insulate it firmly. There are three common fatal problems in terminal blocks: ...

Fault solution for three-phase asynchronous motor - LS power generation Fault solution for three-phase asynchronous motor - LS power generation

1. The motor cannot roll after being energized, but there is no abnormal noise, no peculiar smell and smoke. 1. Cause of the problem: (1) The power supply is not connected (at least two phases are not connected); (2) Fuse blowing (at least two-phase blowing); (3) The overcurrent relay is adjusted too small; (4) The wiring of the control equipment is faulty. 2. Question ...

Specification steps for the safe operation of generator sets – power generation Specification steps for the safe operation of generator sets – power generation

Standardized procedures for safe operation of generator sets 1. Preparation before starting (1) The operators of the computer room should abide by the safety operation procedures, wear work clothes and insulated shoes, and the crew should have a clear division of labor. (2) Check whether the flywheel and part of the generator are not defective. ...

LS power terminal is faulty LS power terminal is faulty

From the perspective of application, the function of the terminal block should be achieved: the contact part should be conducted, and the contact should be reliable. The insulating parts should not be conducted, and it is necessary to insulate them firmly. There are three common forms of fatal failure of terminal blocks: ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top