The cause of motor burnout caused by inverter - LS generates electricity

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

In fact, the problems of the motor are not the cause of the motor itself, most of them are caused by the non-standard debugging of the inverter or the wrong inverter motor when the inverter motor is used, etc., mainly due to the following situations:

                                  The cause of motor burnout caused by inverter - LS generates electricity

1. Use the general motor as a frequency conversion motor

Because the general motor cooling fan is connected with the rotating shaft, when the speed is regulated by the inverter, the speed is unstable, and the additional speed of the motor cannot be reached, and the cooling fan cannot play a normal role, causing poor heat dissipation of the motor; In addition, the general motor is not designed according to the requirements of frequency conversion, so that the motor is heated or incinerated .

2. The inverter motor and the inverter are directly connected together without debugging

The two commonly used methods of inverter control motor are vector control and V/F curve control, each control method must first set the type of motor (synchronous, asynchronous, with or without encoder), additional power of the motor, additional voltage, additional current, speed or number of poles, additional frequency, high operating frequency, acceleration and deceleration time of motor start and stop, maintenance method of inverter control motor and maintenance ratio factor, carrier frequency, etc., all of which are indispensable. Once these parameters are set, you can choose whether you want to control them by vector or V/F. When selecting vector control, the motor should be paired with the inverter with no-load dynamic self-learning or static self-learning with load, and the motor and inverter after self-learning can play the best performance of vector control; When selecting V/F control, there is no need to learn by itself, and the parameters are adjusted and directly energized.

3. The running direction of the fan of the variable frequency motor is inconsistent with the direction of rotation indicated on the fan, and the fan cannot play a role, causing the heat dissipation of the motor to deteriorate, and the heat generated by the motor cannot be released, causing the motor to heat up or incinerate.

4. 2 or 3 of the above three conditions occur more often

In view of the above situation, it is recommended that customers choose the inverter to control the motor, to select the inverter motor, the inverter to select a good quality manufacturer, although the initial investment is a little higher, but the quality is guaranteed, the operation time is long without problems, it is not easy to cause the motor or inverter defects caused by the shutdown, etc., and the quality of the inverter after-sales service is guaranteed, the response time is fast.

More on that
The protection measures of the power generator inverter for the motor The protection measures of the power generator inverter for the motor

The protection of the motor by the power converter mainly includes the following aspects: overvoltage protection, undervoltage protection, overcurrent protection, phase loss protection, inverter protection, overload protection, grounding protection, short circuit protection, overfrequency protection and stall protection. ...

The basic principle of motor protector selection - LS power production The basic principle of motor protector selection - LS power production

The fundamental method of motor protector selection At present, there is no unified standard for motor protectors on the market, and almost every manufacturer has its own type standard. In order to meet the needs of different customers, manufacturers derive many products with different uses, and a wide range of products for the majority of users to choose ...

Why can't the inverter be equipped with a leakage protector - power generation Why can't the inverter be equipped with a leakage protector - power generation

When using an inverter, a leakage maintainer must not be used. This is a major principle of the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...

LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years. LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years.

In Clarivate's recent statement, LS Electric was named one of the top 100 innovators in the world. The trophy handover ceremony was held in Anyang, LS Electric R&D Park, with Kim Yeong-geun, Chief Technical Officer of LS Electric, and Ahn Seong-sik, CEO of Clarivate Korea, acting as representatives of both parties.

Interference phenomenon of LS power inverter Interference phenomenon of LS power inverter

1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly; 2. In the water supply controlled by the inverter, the pressure transformer is used as a signal to collect the pressure, and the pressure transformer is disturbed by the inverter; 3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently; 4. Pressure transformer (4-20 ...

Inverter exception handling method - LS power generation Inverter exception handling method - LS power generation

1. The working temperature of the inverter is high 1. Check whether the ambient temperature of the inverter is too high; 2. Check whether the cooling fan inside the device is working properly; 3. Check whether the ventilation pores and mask grilles are blocked; 4. Check if the load is too heavy. ...

Contactors play a role in industrial electricity Contactors play a role in industrial electricity

The contactor is an automatic switch for industrial roofs to control its on/off with a button. The contactor consists of an electromagnetic coil, a static armature, a moving armature, a static contact, a moving contact and a fixing bracket. The principle is that when the electromagnetic coil of the contactor is connected to the communication electricity, a strong magnetic field will be generated to make the center of the coil ...

The touch screen controls the inverter steps The touch screen controls the inverter steps

1. The touch screen is controlled by PLC inverter 1. At present, the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

Introduction to the working principle of LS electric molded case circuit breaker Introduction to the working principle of LS electric molded case circuit breaker

Molded case circuit breakers are also known as equipment circuit breakers, all parts are sealed in plastic housings, auxiliary contacts, undervoltage trippers and shunt trippers are modular. Because of the very compact structure, the molded case circuit breaker is basically impossible to maintain. It is mostly manually operated, and the large capacity ...

Introduction to the matching of LS power inverter loads Introduction to the matching of LS power inverter loads

1. Square torque load Fan and pump loads are the most widely used equipment in industrial sites, and frequency converters are used in this type of load. It is a square torque load. In general, inverters with U/f=const control mode can be satisfied with the ...

Introduction to inverter self-learning motor - LS power generation Introduction to inverter self-learning motor - LS power generation

1. What is a self-learning motor of inverter? Enter the motor nameplate (voltage, current, Hz rating) in the inverter parameters, and then the inverter actively measures other parameters of the motor. Second, why should the inverter learn by itself?

LS has reached agreements with Doosan and Hanwha in Korea on a business model for vacuum power generation LS has reached agreements with Doosan and Hanwha in Korea on a business model for vacuum power generation

LS Electric recently signed an MOU agreement with Doosan Fuel Cell, Hanwha Power Systems, and Hanwha Asset Management in Seoul, Korea, to establish a business partnership for city gas companies to develop a fuel cell-vacuum power generation business model. Through this agreement, the two sides will expand the scope of cooperation ...

LS power production automation subdivision industry service era LS power production automation subdivision industry service era

LS power automation drives are mainly for industrial enterprises and construction enterprises, including municipal, metallurgical, electric power, chemical and other power-oriented industrial enterprises, car, food and beverage, pharmaceutical and other professional enterprises, as well as OEM equipment manufacturing enterprises. ...

The wiring distance between the motor and the inverter The wiring distance between the motor and the inverter

Burn two new motors in a row! The output current and voltage of the inverter are balanced, the input voltage is balanced, the current is unstable, and the fluctuation is 20%-50%, the inverter is burned off by a short circuit between 35Hz turns, the grid voltage is very stable, 720V, the interval between the motor and the inverter is 120m, and the input and output terminals of the inverter are powered ...

The internal accessory component of the circuit breaker - the power production circuit breaker The internal accessory component of the circuit breaker - the power production circuit breaker

1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.

Precautions for inverter installation and wiring - LS power generation Precautions for inverter installation and wiring - LS power generation

The inverter is an electric power control equipment that uses frequency conversion skills and microelectronic skills to control the AC motor by changing the power supply frequency of the motor operation. It is used in a wide range of fields, including conveyors, feeders, mixers, grinders, pulverizers, paper cutters, calenders in various industries...

Six misunderstandings in the installation and use of inverters - electricity production Six misunderstandings in the installation and use of inverters - electricity production

Myth 1: Connect electromagnetic switches and electromagnetic touches in the output circuit of the inverter In practical application, some occasions need to use the touch device for frequency converter switching: such as switching to the power frequency state when the frequency conversion is faulty, or the election is used to drag two methods, a motor is faulty, and the variable frequency is used.

Introduction to electrical equipment - LS Electricity Introduction to electrical equipment - LS Electricity

According to the requirements of safe, high-quality, reliable and economical operation of the production, transforming, transportation, distribution and use of electric energy in power plants and substations, the following electrical equipment is mainly included. 1. Primary equipment Directly involved in production, ...

The advantages of the inverter in practical application - LS power generation The advantages of the inverter in practical application - LS power generation

With the continuous progress of industrial automation, inverters have also been widely used, energy conservation and environmental protection as the core of China's industrial economy, in the direction of the sustainable development of China's industry, but also useful to promote the sustainable development of China's inverter profession, so that I ...

Manufacturing Automation Terminology – LS Electricity Generation Manufacturing Automation Terminology – LS Electricity Generation

I/O Points: When discussing control systems, I/O points are a term that is often heard. It refers to the input/output point, I stands for INPUT, which refers to the input, and O stands for OUTPUT, which refers to the output. The inputs/outputs are for the control system, and the input refers to the ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top