1. HW problem
This problem may be a fault unique to LG-IG5 series inverters, and the main causes are as follows:
(1) Damage to the cooling fan. Due to the use environment and other factors, the friction of the fan bearing is too large, which causes the fan load to be large and the HW problem appears;
(2) The damage of the built-in temperature detection circuit of the power module will also cause HW problems;
(3) In addition, the motherboard problem also simply causes the HW problem.
2.Ground fault problem
Grounding problem is also a problem we usually encounter, in addition to eliminating the cause of the motor grounding problem, the most likely problem part is the Hall sensor, Hall sensor due to the influence of temperature, humidity and other environmental factors, the working point is very simple to drift, resulting in GF alarm.
|
More on that
|
Common faults in terminal blocks - LS generates electricity
From the point of view of application, the function that should be reached is: it is necessary to conduct the local area where the touch part should be conducted, and the touch is reliable. If the insulating part should not be conducted, it is necessary to insulate it firmly. There are three common types of faults in terminal blocks:
...
|
|
The reason why the inverter cannot be equipped with a leakage protector
When using an inverter, a leakage maintainer must not be used. This is a major principle of the use of frequency converters.
Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together, the leakage maintainer acts, and the system foundation cannot be ...
|
|
PLC installation and wiring skills - LS power generation
The PLC should be kept away from strong disturbance sources such as electric welding machines, high-power silicon rectifier equipment and large-scale power equipment, and cannot be installed in the same switch cabinet as high-voltage electrical appliances.
Power cables, control cables, and PLC power cables and I/O cables should be separated from the wiring ...
|
|
Switching analysis and synchronous control of inverter - LS power generation
AC asynchronous motors are widely used in all walks of life, and frequency converters and power frequency power supplies are often required to switch in the selection of frequency conversion speed control system. The primary types of switching are: fault switching and multi-machine system switching. In the process of operation of many production machinery, the motor is not allowed to stop ...
|
|
Energy-saving method of ventilator inverter - LS power generation
high-power
Although some inverters are fan type inverters, but it is a low-power fan inverter, such an inverter does not have the effect of energy saving, and it is necessary to achieve energy saving must be a high-power inverter, in addition to the high-power fan inverter, it is necessary to meet its ...
|
|
LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years.
In Clarivate's recent statement, LS Electric was named one of the top 100 innovators in the world. The trophy handover ceremony was held in Anyang, LS Electric R&D Park, with Kim Yeong-geun, Chief Technical Officer of LS Electric, and Ahn Seong-sik, CEO of Clarivate Korea, acting as representatives of both parties.
|
|
Automatic adjustment of motor parameters - LS power generation
Step 1: If the motor can be completely separated from the load, in the case of a power failure, the motor is mechanically separated from the load, and the motor is allowed to rotate freely without load.
Step 2: After powering on, select the VFD command source (F0-04) as the command channel of the operation panel.
...
|
|
Advantages and disadvantages of LS inverter non-sensing vector control
The first generation of LS inverter selects the voltage frequency ratio scalar control method, which carries out frequency conversion speed regulation according to the linear ratio determined by the equivalent circuit of the asynchronous motor. Voltage refers to the effective value of the fundamental wave, and changing U/f can only regulate the steady-state magnetic flux and torque of the motor, not to mention dynamic control. In order to improve the low ...
|
|
The production power takes you to read the PLC ladder diagram
1. Trapezoidal stairs start from the horizontal line and end up with a vertical line (generally you can omit not to draw, only draw the left busbar). On the left side of each row is the junction combination, indicating the conditions that drive the logic coil, while the logic coil indicating the effect can only be connected to the bus on the right. The contact can not appear in the coil right ...
|
|
The inverter generates electricity through the principle of intermediate DC bus power supply - LS
Most of the inverter manufacturers produce traditional inverters, and their control systems and other power supplies are directly provided by single-phase or three-phase power grids. However, due to the increasing use of VFDs and servo motor amplifiers, a new power supply may emerge: powered by the central DC bus of the VFD. This electric ...
|
|
LS static test to determine the fault of the inverter
Generally, the general-purpose inverter roughly includes the following parts: (1) rectifier circuit; (2) DC central circuit; (3) Inverter circuit; (4) Control circuit. The static test is mainly a test of the high-power transistors (power modules) of the rectifier circuit, DC center circuit and inverter circuit. Whole...
|
|
LS power generation installs the switching power supply step
The basic method of switching the power supply of the device requires us to carry out the corresponding installation and debugging according to the specific model and the device environment. And in the process of installation, we need to pay more attention to safety and stability to ensure the normal operation of the switching power supply.
...
|
|
Methods for extending the service life of inverters - LS generates electricity
1. The influence of electromagnetic disturbance on the inverter:
In the modern industrial control system, the microcomputer or PLC control technology is mostly selected, and in the process of system planning or transformation, it is necessary to pay attention to the disturbance of the inverter to the microcomputer control board. The inverter is disturbed by the outside world, because the user ...
|
|
The vector control mode of low-voltage general-purpose inverter - LS power generation
The method of vector control frequency conversion speed regulation is to change the stator current Ia, Ib, Ic of the asynchronous motor in the three-phase coordinate system, after the three-phase - two-phase change, equivalent to the communication current Ia1Ib1 under the two-phase static coordinate system, and then after the directional rotation according to the rotor magnetic field, it is equivalent to synchronous rotation sitting.
|
|
How to operate LS inverters
1. When the power supply is now powered or the inverter is in running condition, do not open the shell of the inverter. Otherwise, an electric shock may occur.
2. When the front cover of the inverter is opened, do not move the inverter. Otherwise, you may be shocked by the high-voltage terminals or exposed charging capacitors. ...
|
|
Calculation method of filter capacitance value of inverter
Alternating current can be converted into direct current using rectifier electricity, but in three-phase electricity, this DC voltage or current contains voltage or current ripple with a frequency of six times the frequency of the power supply. In addition, the inverter inverter will also generate ripple voltage or current due to output and carrier frequency, etc., and reverse ...
|
|
The difference between LS power inverter and servo
An important difference between servo and frequency conversion is that frequency conversion can be without encoder, while servo must have an encoder for electronic commutation.
1. What the two have in common:
The AC servo technology itself is to learn and apply the technology of frequency conversion, and the servo control of the DC motor is based on the ...
|
|
How to troubleshoot the fault of the inverter - the power inverter
Because the application method is incorrect or the setting environment is unreasonable, the inverter will simply malfunction and cause problems, or the expected operation effect will not be satisfied. In order to prevent problems before they occur, it is important to carefully analyze the cause of the problem in advance.
...
|
|
Electromagnetic interference caused by the working principle - LS power inverter
1. Harmonic disturbance
The rectifier circuit will produce harmonic current, which produces a voltage drop on the impedance of the power supply system, resulting in distortion of the voltage wave pattern, and the voltage of this distortion constitutes a disturbance on many appearances, and the common voltage distortion is the flattening of the top of the sine wave. Harmonic wave...
|
|
LS takes you to understand the inverter in the inverter
Contrary to the rectifier, the inverter converts the DC power into the communication power of the required frequency, and the 3-phase communication output can be obtained by turning on and off the 6 switching devices at the confirmed time. Take a voltage-type PWM inverter as an example to show the switching time and voltage waveform.
Control circuit ...
|
|