1. How to distinguish between heavy and light faults
When there is a problem with the light, the system announces the alarm signal and the fault indicator flashes. When there is a serious problem, the system will announce the problem indicator, the problem indicator will always be on, together with the announcement of the disconnect high voltage and stop the closing order, and store the problem information and the high voltage breaking command. If the heavy problem condition is not eliminated, the problem indication and high-voltage interrupting command are still useful.
2. What are the small questions
Lighting problems include: transformer overheating alarm, cabinet overheating alarm, cabinet door opening, unit bypass, system no recall to deal with lighting problems, as long as the problem is indicated, the alarm is actively eliminated after the problem disappears. If there is a slight problem during the operation of the inverter, the system will not stop. When there is a slight problem alarm when the machine is stopped, the inverter can continue to operate.
3. What is the first question
When the following problems arise in the system, it should be regarded as a serious problem. The top types of problems appear in the upper left corner of the monitor: external problems, transformer overheating, cabinet overheating, unit faults, inverter overcurrent, high voltage power loss, interface board problems, controller not communicating, interface board not communicating, motor overload, parameter faults, and master control board issues. Unit problems include fuse faults, unit overheating, drive faults, fiber fiber faults, and unit overvoltages. Regarding external problems, the high-voltage disconnection (cabinet door button or external connector) must be disconnected before the system is reset to restore the system to normal condition; After a serious problem other than an external problem occurs, it is possible to reset the system directly to restore the system to normal condition, but the cause of the problem must be found before the power is applied again. After the unit fault occurs, the unit condition can only be detected as long as the high-voltage power supply is turned on again. If the fault is difficult to analyze and it is not possible to confirm whether the high voltage can be turned on again, consult the manufacturer. Note: Don't rush to power on again until you find the cause of the problem, otherwise the inverter may be severely damaged!
4. Transformer over-temperature alarmWhen the measured temperature of the transformer temperature controller is greater than its set alarm temperature (the default setting is 100°C), the over-temperature alarm contact of the temperature controller is closed.
Check whether the operation of the top fan or the bottom fan of the transformer cabinet is normal (if the operation of the bottom fan is abnormal, the three-phase temperature difference may be large); Whether the temperature resistance is normal (whether the wire is disconnected, whether the line plug is in poor contact, whether the contact is poor, whether the temperature value is high); Check whether the filter is blocked (take a piece of A4 paper and put it on the filter to see if it can be adsorbed, otherwise clean the filter); whether the inverter is overloaded for a long time; whether the ambient temperature is too high (the ambient temperature should be lower than 45°C, otherwise ventilation should be strengthened); Whether the fan switch and contactor installed at the bottom of the front of the transformer cabinet are disconnected; Whether the fan control and protection circuits of the transformer cabinet are normal.
5. Cabinet temperature over-temperature alarm unitWhen the cabinet temperature point temperature is greater than 55°C, the system announces the cabinet temperature over-temperature lamp fault alarm.
Check whether the fan on the top of the cabinet is working normally, and whether the fan switch installed in the secondary room trips; Check whether the filter is blocked (take a piece of A4 paper and put it on the filter screen to see if it can be adsorbed, otherwise clean the filter screen); whether the inverter is overloaded for a long time; whether the ambient temperature is too high (the ambient temperature should be below 45°C, otherwise ventilation should be strengthened (ventilators installed on the wall or air ducts installed on the top of the cabinet) or refrigeration equipment); Whether the control and protection circuit of the fan of the transformer cabinet is normal.
6. The transformer is overheated, and the temperature measured by the transformer temperature controller is higher than its set trip temperature (the default setting is 130°C). while
How to repair the inverter fault? Under this classification, it is to collect and display some common fault codes, give the causes of the fault and the treatment plan, in addition to querying and dealing with the problem, it can also improve the common sense skills in a targeted manner, and the practicability is very strong.
|
More on that
|
The cause of motor burnout caused by inverter - LS generates electricity
In fact, the problems of the motor are not the cause of the motor itself, most of them are caused by the non-standard debugging of the inverter or the wrong inverter motor when the inverter motor is used, etc., mainly due to the following situations:
1. Put the general motor ...
|
|
LS power converter interference phenomenon
1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly;
2. Use the inverter to control the water supply, the pressure transformer is used as the signal to collect the pressure, and the pressure transformer is disturbed by the inverter;
3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently;
4. Pressure transformer (4-20 ...
|
|
Inverter load test run step - LS power generation
1. Manually operate the work stop button of the inverter panel, investigate the work stop process of the motor and the display window of the inverter to see if there is any abnormal phenomenon.
2. If the inverter presents an overcurrent maintenance action during the process of starting P to abort the motor, ...
|
|
Selection of the color of the conductor of the high and low voltage switchgear - LS power production
1 AC three-phase circuit
a) Yellow for phase A, green for phase B, and red for phase C;
b) Light and blue colors for the neutral line or neutral line;
C) Yellow and green two-color wires are used for safety grounding wires.
2 AC circuits connected by twinax wires or stranded wires: red, black ...
|
|
LS power inverter function
1. Soft up
The direct launch of the inverter motor has a serious impact on the power grid, and it will also have too high requirements for the capacity of the power grid, which is extremely unfavorable to the service life of equipment and power grid circuits. After the use of inverter to save energy, the use of inverter's speed regulation (V/F) function will make the starting current from a small ...
|
|
The method of judging the quality of components - LS power production
1. Detection of ordinary diodes
Use the MF47 multimeter to measure, connect the red and black watch pens to the two ends of the diode, read the reading, and then adjust the watch pen to measure. According to the results of two measurements, the forward resistance value of the general low-power germanium diode is 300-500Ω, and the silicon diode ...
|
|
LS power production contactor application
LS touchers are divided into AC touchers (voltage AC) and DC touchers (voltage DC), which are used in electricity, power distribution and consumption. Toucher broadly refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field in industrial electricity, so that the contacts are closed, so as to control the load.
...
|
|
Whether the C-type circuit breaker is suitable for the motor circuit - power generation
Type C micro-break is used for general circuits, such as lighting circuits; D-type circuit breakers are used in power circuits such as electric motors, so can C-type micro-breakers be used in motor circuits?
Differences between C-type and D-type discontinuity:
C-type micro-disconnect: with ...
|
|
Inverter fault handling - LS power generation
1. The working temperature of the inverter is high
1. Check whether the ambient temperature of the inverter is too high;
2. Check whether the cooling fan inside the device is working normally;
3. Check whether the ventilation pores and mask grilles are blocked;
4. Check if the load is too heavy.
...
|
|
The main part of LS power inverter is composed
The inverter circuit is the first part of the inverter
The function of the DC central circuit is to smooth the output of the rectifier circuit to ensure that the inverter circuit and the control power supply can obtain a DC power supply with higher quality. When the rectifier circuit is the voltage flow of the central circuit, the primary component is the electrolysis of Darongtong ...
|
|
The basic problem of LS electric molded case circuit breaker
Rated current of LS molded case circuit breaker:
Now in the process of using the molded case circuit breaker, it is necessary to understand the rated current of the molded case circuit breaker, and the rated current of the molded case circuit breaker is generally more than a dozen, mainly 16A...
|
|
Selection principles and key points of AC contactors for power production
1. The coil voltage of the contactor should generally be lower, so that the insulation requirements of the contactor can be reduced, and it is safer to use. However, in order to facilitate and reduce the equipment, it is often selected according to the actual grid voltage.
2. The operating frequency of the motor is not high, such as compressor, water pump, air ...
|
|
How to select servo motor - power production
Each type of servo motor has additional torque, maximum torque and servo motor inertia and other parameters in the standard items, each parameter and load torque and load inertia must have a relevant connection, the output torque of the servo motor should meet the requirements of the movement conditions of the load organization, such as the speed of the acceleration ...
|
|
Variable frequency regenerative braking method - LS generates electricity
1. Energy consumption type
This method is to connect a braking resistor in parallel in the DC circuit of the inverter, and control the on/off of a power tube by detecting the DC bus voltage. When the DC bus voltage rises to about 700V, the power tube is turned on, and the regenerative energy is passed into the resistor.
|
|
LS power generation installs the switching power supply step
1. Confirm the location of the device
Before the equipment switches on and off the power supply, it is necessary to confirm the location of the equipment, and generally require the equipment to be in a ventilated, boring, non-corrosive gas and dust-free place.
2. Equipment holder
The fixed base of the switching power supply is fixed on the orientation of the equipment, and the general ...
|
|
Common faults and countermeasures of power inverters
1. OC failure
Like other inverters, overcurrent alarm is also a common fault of power inverter, in addition to the reasons for parameter settings such as acceleration and deceleration time, there are mainly the following possibilities in hardware: damage to high-power modules may cause OC alarm, low-power economical inverter ...
|
|
How to use the installation wiring of the LS inverter
1. Circuit wiring
(1) The input (R, S, T) and output (U, V, W) of the inverter cannot be connected incorrectly;
(2) Wire diameter selection
(1) The wiring of the power supply and the inverter and the wire diameter selection method of the motor of the same capacity are the same;
(2) The wiring between the inverter and the motor should consider the line electricity.
|
|
Maintenance and maintenance method of electric motor - LS generates electricity
1. Look: The normal operation of the motor has a great relationship with the surrounding environment. Therefore, during the daily inspection, check the water leakage and dripping conditions around the motor (which will cause the low insulation of the motor to form breakdown and burn out), and check whether the peripheral of the motor has affected its ventilation and heat dissipation ring.
|
|
Models and features of LS Metasol series products
Metasol series MS (100A and below) products are newly launched and the primary product specifications: contactors, thermal relays, and center relays.
Features:
The body is small, the internal structure is sealed, and the safety factor is high
...
|
|
The basic problem of LS electric molded case circuit breaker
Rated current of LS molded case circuit breaker:
Now in the process of using molded case circuit breakers, it is necessary to understand the rated current of molded case circuit breakers, and the rated current of molded case circuit breakers generally has more than a dozen, mainly 16A, 25 A, 30A, and the high may reach 630A.
...
|
|