1. OC failure
Like other inverters, overcurrent alarm is also a common fault of power inverter, in addition to the reasons for parameter settings such as acceleration and deceleration time, there are mainly the following possibilities in the hardware: the damage of the high-power module may cause OC alarm, the low-power economical inverter uses the PIM module of TYCO company, the general-purpose medium-power inverter uses the PIM module produced by Fuji and the IGBT module of Mitsubishi company, and the high-power inverter uses the IGBT module of Siemens. The damage of high-power modules can be caused by the following reasons:
(1) The output load is short-circuited and out of phase;
(2) The load is too large, and the high current continues to appear;
(3) The load fluctuates greatly, resulting in excessive inrush current, which may cause OC alarm and damage the power module.
2. HW failure
This fault may be a fault unique to LS-IG5 series inverter, and the main causes are as follows:
(1) Damage to the cooling fan. Due to the use environment and other reasons, the friction of the fan bearing is too large, causing the fan load to be too large and showing HW failure;
(2) The damage of the built-in temperature detection circuit of the power module will also cause HW failure;
(3) In addition, the failure of the motherboard is also easy to cause HW failure.
3.Ground fault
Grounding fault is also a fault that we usually encounter, in addition to eliminating the cause of the problem with the grounding of the motor, the most likely part of the failure is the Hall sensor, the Hall sensor is affected by environmental factors such as temperature and humidity, the working point is easy to drift, resulting in GF alarm.
4. No display failure
No display faults are usually caused by damage to the switching power supply. Different from ordinary self-excited or separately excited switching power supplies, LG inverter uses a controllable voltage regulator device called TL431 to adjust the duty cycle of the switch to achieve the purpose of stabilizing the output voltage. When there is a short circuit of the load, it often causes the switching power supply to block the output, and the panel is not displayed. Like other inverters, such as LV and OV faults, drive circuit damage faults will also be encountered in the power generation inverter, which requires us to constantly summarize and explore in practice.
5. FU failure
LS-IS5 and IH series inverters are equipped with fast fuse detection, because the breaking capacity of the fast fuse can reach about 5 ms, so when there is a large current through the inverter, the fast fuse can operate, so as to protect the high-power module. However, due to the damage of the fast fuse, it also caused the occurrence of FU failure. Replace the quick fuse.
|
More on that
|
How LS produces power PLC operation
Although many relays, timers and counters are often used in the ladder diagram programs used by LS PLC, LS PLC does not have these hardware physically, but uses memory and program programming methods to make logic control modifications, and connects external machines through output components.
|
|
Inverter applications and common loads – LS generates electricity
1. Air conditioning load
Office buildings, shopping malls and some supermarkets and factories have central air conditioning, and the electricity consumption of air conditioning is very large during the peak electricity consumption in summer. In hot weather, the electricity consumption of air conditioners in Beijing, Shanghai and Shenzhen accounts for more than 40% of peak electricity. Therefore, with inverter equipment, drag the air conditioning system ...
|
|
DC reactor for inverter and design calculation - LS power generation
The DC reactor for the inverter is also called the flat wave reactor, which is connected in series in the DC bus (terminals P1 and P+). The main thing is to reduce the higher harmonic component of the input current and improve the power factor of the input power supply (to 0.95). This reactor can be used at the same time as the AC reactor, and the inverter has high power ...
|
|
Analysis of heat dissipation problems of inverter - LS power generation
In order to use the inverter correctly, it is necessary to consider that the service life of the VFD decreases exponentially with the increase in temperature. This is due to: When the ambient temperature rises by 10 degrees, the service life of the VFD is halved. So pay attention to heat dissipation! When the VFD is working, the current flowing through the VFD is very large, and the VFD emits ...
|
|
How LS PLC works
Although many names such as relays, timers and counters are often used in the ladder diagram programs used by LS PLC, LS PLC does not have these hardware physically, but uses memory and program programming to do logic control and editing, and connects to external machines through output components.
|
|
The main part of LS power inverter is composed
The inverter circuit is the first part of the inverter
The function of the DC central circuit is to smooth the output of the rectifier circuit to ensure that the inverter circuit and the control power supply can obtain a DC power supply with higher quality. When the rectifier circuit is the voltage flow of the central circuit, the primary component is the electrolysis of Darongtong ...
|
|
Recommended models for power production contactors
GMC-6 Contactor GMC-6 Rated voltage: 110V/22OV/380V;
GMC-9 Contactor GMC-9 Rated voltage: 110V/22OV/380V;
GMC-12 Contactor GMC-12 Rated voltage: 110V/22OV/380V;
GMC-18 Contactor GMC-18 Rated voltage 110V/ ...
|
|
Types of PLCs that produce electricity
There are many categories of PLC, and the following is a brief introduction to PLC and its main functions
As an innovative PLC product family that combines the technical capabilities of power production and production, XGT is a system based on open networks, ultra-high-speed processing speeds, compact size and a large number of improved software.
|
|
Types and characteristics of PLC digital output modules for power production
The main functions and functions of PLC:
1. For sequential control: sequential control is based on the current and pre-historical situation of the input switch, and produces the required switching output, so that the system can operate in a certain order. ...
|
|
Inverter maintenance fault handling method - LS power generation
1. Not manifested. This situation is more common, generally in the normal condition of the external three-phase power supply, it is the switching power supply of the inverter burned, and the 24 volt power supply on the output board of the inverter terminal can be measured.
|
|
The difference between voltage inverter and current inverter - LS produces electricity
For example, the operating principle of voltage inverter is mainly to regulate the voltage source, and the voltage source regulates the current to achieve the role of conditioning, while the current inverter is to directly regulate the current to achieve the role of conditioning.
...
|
|
The working principle of the LS power production module
When the LS power generation module is put into operation, its working process is generally divided into three stages: input sampling, user program fulfillment, and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the upper ...
|
|
Introduction to inverter self-learning motor - LS power generation
1. What is a self-learning motor of inverter?
Enter the motor nameplate (voltage, current, Hz rating) in the inverter parameters, and then the inverter actively measures other parameters of the motor.
Second, why should the inverter learn by itself?
|
|
Relationship between motion control and frequency converter
Motion control has a significant period characteristic, it is a combination of a variety of high-tech to push industrial automation, office automation and home automation to a higher stage. At present, the motion control is mainly composed of three parts: inverter, motor and controller.
...
|
|
The application of the inverter to supply power to the motor has encountered a problem
A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply.
...
|
|
Inverter circuit board repair and drawing-free maintenance method - LS power generation
1. Be "confident"
It is necessary to fully understand the principles of some typical circuits and be familiar with them. Guangzhou Kewo Training Center believes that drawings are dead, and the thoughts in the head are alive, able to make analogies, able to reason, and able to touch analogies. For example, switching power supply is always inseparable from ...
|
|
Elements of LS power inverter operation
1. Physical environment
(1) Temperature factor
Temperature has a huge impact on the lifetime and reliability of the electronic components inside the inverter. When using the inverter in a high operating temperature environment, it is necessary to take additional cooling measures to ensure that the ambient temperature is stable in the inverter.
|
|
Distinguish between good and bad inverters - LS produces electricity
The quality of a thing is relatively speaking, the inverter as a power supply used to drive the motor to run, its function is to regulate the speed, under the premise of normal wiring, reasonable parameters, and no fault with the load, if the speed of the motor can be controlled according to the requirements, the shaking error is less than the equipment ...
|
|
Introduction to electrical equipment - LS Electricity
According to the requirements of safe, high-quality, reliable and economical operation of the production, transforming, transportation, distribution and use of electric energy in power plants and substations, the following electrical equipment is mainly included.
1. Primary equipment
Directly involved in production, ...
|
|
Precautions for inverter installation tips - LS power generation
When the line power supply exceeds the driver's kV-A rating by 10 times, add a line reactor.
A 3% impedance line reactor should be used to reduce power line transients caused by capacitor switching, line notching, DC bus overvoltage tripping, and inverter overcurrent and overvoltage conditions. Line...
|
|