There are additional torque, maximum torque and servo motor inertia and other parameters in the standard items of each type of servo motor, and there must be relevant contact between each parameter and load torque and load inertia, and the output torque of the servo motor should meet the requirements of the motion conditions of the load organization, such as the speed of acceleration and the component of the organization; methods of movement of the organization (horizontal, vertical rotation), etc.; There is no direct relationship between the motion condition and the output power of the servo motor, but the higher the output power of the servo motor, the higher the relative output torque. Therefore, not only the tissue component will affect the selection of the servo motor, but also the motion conditions will also change the selection of the servo motor. The larger the inertia, the greater the acceleration and deceleration torque, and the shorter the acceleration and deceleration time, the greater the output torque of the servo motor. When selecting the servo motor standard, the following process is followed.
(1) Clear requirements for the movement conditions of the load tissue, that is, the speed of acceleration/deceleration, the speed of movement, the component of the tissue, the movement method of the tissue, etc.
(2) According to the requirements of the operating conditions, the appropriate load inertia accounting formula is selected to calculate the load inertia of the organization.
(3) According to the load inertia and servo motor inertia, select the appropriate false selected servo motor standard.
(4) Combined with the inertia and load inertia of the servo motor in the primary selection, the acceleration torque and deceleration torque are calculated.
(5) Calculate the load torque according to the load component, configuration method, friction coefficient, and operation efficiency.
(6) The maximum output torque of the primary servo motor must be greater than the acceleration torque + load torque; If the conditions are not met, it is necessary to use other types of accounting verification until the requirements are met.
(7) According to the load torque, acceleration torque, deceleration torque and insistence torque to calculate the continuous instantaneous torque.
(8) The additional torque of the primary servo motor must be greater than the instantaneous torque, for example, if it does not meet the conditions, it is necessary to use other types of accounting verification until it meets the requirements.
(9) Completion selection.
|
More on that
|
Asynchronous motor with inverter - LS generates electricity
Before the asynchronous motor is equipped with an inverter, let's take a look at the three major types of mechanical equipment loads:
1. Constant torque load: such as conveyor belts and mixers; When the inverter drags a load of constant torque nature, the torque at low speed should be large enough and the overload capacity should be large enough. If you need ...
|
|
The reason why the inverter cannot be equipped with a leakage protector
When using an inverter, a leakage maintainer must not be used. This is a major principle of the use of frequency converters.
Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together, the leakage maintainer acts, and the system foundation cannot be ...
|
|
Recommended models for power production contactors
GMC-6 Contactor GMC-6 Rated voltage: 110V/22OV/380V;
GMC-9 Contactor GMC-9 Rated voltage: 110V/22OV/380V;
GMC-12 Contactor GMC-12 Rated voltage: 110V/22OV/380V;
GMC-18 Contactor GMC-18 Rated voltage 110V/ ...
|
|
LS Electric's motion control system solution on pillow (horizontal) packaging machine
The pillow packaging machine mainly performs the operation of product forming, positioning, packaging and sealing, etc., and the equipment is composed of the packaging film shaft that provides the packaging film, the feeding shaft that provides the material, the cutter shaft that performs the sealing and cutting operation and the discharging shaft after the product packaging is completed, and the equipment structure diagram is as follows:
...
|
|
Inverter overvoltage alarm analysis - LS power generation
Change the shutdown mode to inertia parking and you're done! In this way, after the fan is stopped, the inverter will immediately turn off the output, so that the fan can stop freely, at this time, although the fan is in the power generation situation, but the electricity generated by the fan will not pass through the inverter of the inverter to generate direct current, so the inverter will not overvoltage ...
|
|
What is the difference between LS inverter and LG inverter?
LS inverter and LG inverter are the same, there is no difference between the two.
LS inverter, the full name of LS AC inverter governor, after supplying a variety of configurations, converts direct current into communication power, and changes the general power supply ...
|
|
Analysis of heat dissipation problems of inverter - LS power generation
In order to use the inverter correctly, it is necessary to consider that the service life of the VFD decreases exponentially with the increase in temperature. This is due to: When the ambient temperature rises by 10 degrees, the service life of the VFD is halved. So pay attention to heat dissipation! When the VFD is working, the current flowing through the VFD is very large, and the VFD emits ...
|
|
The main structure of LS power AC contactor
The operating principle of the contactor is: when the contactor coil is energized, the coil current will generate a magnetic field, and the generated magnetic field will make the static iron core attract the moving core with electromagnetic attraction, and drive the communication contactor point action, the normally closed contact is disconnected, and the normally open contact is closed, and the two are linked. When the coil is de-energized ...
|
|
Inverter carrier frequency adjustment method - LS power generation
A. The output voltage of the SPWM inverter is a series of pulses, and the pulse frequency is equal to the carrier frequency.
B. In the current of the motor, there is a harmonic component with a strong carrier frequency, which will cause the vibration of the motor core and announce the noise. If the frequency of the noise is the same as that of the motor core.
|
|
The basic problem of LS electric molded case circuit breaker
Rated current of LS molded case circuit breaker:
Now in the process of using the molded case circuit breaker, it is necessary to understand the rated current of the molded case circuit breaker, and the rated current of the molded case circuit breaker is generally more than a dozen, mainly 16A...
|
|
Inverter applications and common loads – LS generates electricity
1. Air conditioning load
Office buildings, shopping malls and some supermarkets and factories have central air conditioning, and the electricity consumption of air conditioning is very large during the peak electricity consumption in summer. In hot weather, the electricity consumption of air conditioners in Beijing, Shanghai and Shenzhen accounts for more than 40% of peak electricity. Therefore, with inverter equipment, drag the air conditioning system ...
|
|
Wiring method of the main circuit of the inverter - LS power generation
1. The power supply should be connected to the R, S, and T terminals of the VFD, and should not be connected to the VFD (U, V, W), otherwise the VFD will be damaged. It is necessary to clean up the trivial parts of the wire head after wiring, which may lead to abnormalities, failures, and failures, and it is necessary for the VFD to always be clean. When punching holes in the console, note that ...
|
|
The basic principle of motor protector selection - LS power production
The fundamental method of motor protector selection
At present, there is no unified standard for motor protectors on the market, and almost every manufacturer has its own type standard. In order to meet the needs of different customers, manufacturers derive many products with different uses, and a wide range of products for the majority of users to choose ...
|
|
Characteristics of single-phase current converter - LS power generation
Single-phase current transmitter is a kind of power test substation developed for the power measurement of single-phase AC in motor test on the basis of motor test and test technology research, in accordance with IEC and relevant national specifications for motor test. The selection of advanced filtering technology, reasonable software algorithms, processing ...
|
|
The working principle of the LS power production module
When the LS power generation module is put into operation, its working process is generally divided into three stages: input sampling, user program fulfillment, and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the upper ...
|
|
The Importance of Welding in Inverter Maintenance – LS Generates Electricity
Whether the welding skills of the inverter repair personnel are excellent is directly related to the quality and results after repair. If the welding quality is not up to standard during repair, the pins of the components will be broken when the components are disassembled, the printed circuits on the PCB will be damaged, the components will not be soldered firmly when the components are installed, and the two components ...
|
|
The wiring distance between the motor and the inverter
Burn two new motors in a row! The output current and voltage of the inverter are balanced, the input voltage is balanced, the current is unstable, and the fluctuation is 20%-50%, the inverter is burned off by a short circuit between 35Hz turns, the grid voltage is very stable, 720V, the interval between the motor and the inverter is 120m, and the input and output terminals of the inverter are powered ...
|
|
Fatal failure of LS power terminal block
From the point of view of application, the function that should be reached is: it is necessary to conduct the local area where the touch part should be conducted, and the touch is reliable. If the insulating part should not be conducted, it is necessary to insulate it firmly. There are three common fatal problems in terminal blocks:
...
|
|
Fault analysis of servo motors – LS power generation
1. Problem phenomenon: servo error OL, servo motor can not start, and there is abnormal sound problem analysis and possible causes:
(1) Bearing damage, foreign objects falling and stuck, stator magnet bursting and falling or moving tissue jamming caused by the motor itself.
(2) ...
|
|
The torque of the inverter is directly used as the controlled quantity mode - LS generates electricity
VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. Its common disadvantages are low input power factor, large harmonic current, large demand for energy storage capacitors in DC circuits, and renewable energy can not be reflected back to the grid, that is, it cannot carry out four-quadrant operation.
|
|