1. Look: The normal operation of the motor has a great relationship with the surrounding environment. Therefore, in the process of daily inspection, check the water leakage and dripping conditions around the motor (which will cause the low insulation of the motor to form a breakdown and burn out), and check whether there are objects around the motor that affect its ventilation and heat dissipation environment. In order to ensure the cooling and heat dissipation of the motor, the external part of the motor is treated at a high frequency and at regular interval, although the dirt of the end cover and fan blades of the electric fan seems to have little effect, in fact, it accounts for a large proportion of the daily protection of the motor.
2. Touch: Experienced maintenance personnel can judge the operation status of the motor by touching their hands. Rome was not built in a day, and the accumulation of long-term experience is also an important part of the daily inspection and protection of electric motors. If the overall temperature of the motor is higher than the normal operating temperature, it is necessary to check the load, assembly and ventilation of the motor in combination with the motor operating current, and when the bearing condition is good, the temperature at both ends will be lower than the temperature of the center winding section.
3. Measurement: When the motor stops working, it is necessary to measure the insulation resistance of each phase or relative of the motor with an insulation meter at regular intervals (preferably every month), and find the insulation defects in time after comparing with the results of the previous month's test. Taking a three-phase asynchronous motor as an example, the measured unbalance of the three-phase resistance cannot exceed 2%, and when the insulation resistance is checked, if it is lower than 5MΩ, it is necessary to analyze the cause of this abnormal condition. Check whether the insulation is damp, or whether the grounding condition is formed due to poor insulation of the windings, etc. If the three-phase resistance of the stator is unbalanced, the three-phase resistance of the motor coil is separated from the ground withstand voltage test and the inter-turn test has been found out of the grounding point. Unless there are special circumstances, do not turn off the heating switch of the motor equipped with electric heating. If the motor is found to be soaked in water, the motor should be broken and the rotor should be extracted, and then dried with compressed air, and then baked from both ends of the motor stator with a baking lamp until the motor is properly insulated.
4. Listening: The sound discrimination of motor operation is also an important part of motor viewing and protection. Since the machine room can be noisy, it is important to rely on auxiliary tools such as screwdrivers or listening sticks. Close to the two ends of the motor, after a long period of accumulation, we can not only find the bad vibration of the motor and its driving equipment, but also can judge the amount of internal bearing oil. Timely addition of bearing oil or replacement of new bearings and other methods can significantly prevent the blockage, outer circle, and burnout of the motor bearing caused by the lack of oil and dry grinding.
5. Do: The abnormal condition of some motors may not be easy to detect, and the screws, wiring fastening, dismantling and viewing, cleaning and maintenance of the motor according to the maintenance cycle (generally one month) can often cause unexpected effects. If you don't look at it and don't do it, or just look at it and don't do it, it will eventually form a problem or incident. For example, the motor wiring stud is loose and the virtual touch causes the lack of phase burnout, and the motor burns out if the lubricating oil is not replenished in time or the contract is replaced. Insist on carefully looking, touching, measuring, doing, listening, the vast majority of faults can be glazed to prevent and prevent, these fundamental protection methods have a great meaning for the protection and daily maintenance of the motor, but this is far from enough, as mentioned earlier, the continuous accumulation of experience, and constantly summarize and refine to improve the ability of personal motor protection and maintenance, is the condition for us to improve the power of the motor and improve the output.
|
More on that
|
Switching analysis and synchronous control of inverter - LS power generation
AC asynchronous motors are widely used in all walks of life, and frequency converters and power frequency power supplies are often required to switch in the selection of frequency conversion speed control system. The primary types of switching are: fault switching and multi-machine system switching. In the process of operation of many production machinery, the motor is not allowed to stop ...
|
|
Introduction to the control method of LS power inverter
Inverter control method: low-voltage general frequency conversion output voltage is 380-650V, output power is 0.75-400kW, operating frequency is 0-400Hz, and its main circuit adopts AC-DC-AC circuit. Its control methods have gone through the following five generations.
1U/f=C sine pulse width modulation ...
|
|
The size of the contactor is selected by the type of contactor - LS produces electricity
1. Select the corresponding category of contactor according to the control object, operation times and application category of the contactor.
2. Select according to the rated voltage of the line at the application location.
3. Select the rated current of the main contact of the contactor according to the load capacity.
4. About the voltage level of the lead coil ...
|
|
Briefly describe LS ABE203b molded case circuit breaker
The circuit breaker is a fundamental low-voltage electrical appliance, which has the function of overload, short circuit and undervoltage maintenance, and has the ability to maintain the line and power supply. Circuit breaker is an indispensable product in electrical safety. Due to different applications, there are molded case circuit breakers, frame circuit breakers, miniature circuit breakers, etc.
|
|
After the contactor is energized, the start button continuously engages and disconnects ?—— LS generates power
What is the reason why the contactor keeps engaging and disconnecting by pressing the start button after the AC contactor is energized?
In my personal opinion, most of the situation is caused by the wrong coil voltage of the replacement AC contactor, or the purchase of ...
|
|
Energy-saving method of ventilator inverter - LS power generation
high-power
Although some inverters are fan type inverters, but it is a low-power fan inverter, such an inverter does not have the effect of energy saving, and it is necessary to achieve energy saving must be a high-power inverter, in addition to the high-power fan inverter, it is necessary to meet its ...
|
|
Three-phase motor current is too high - LS power generation
First, the power supply problem
1. The power supply voltage is too high
When the power supply voltage is too high, the motor back electromotive force, magnetic flux and magnetic flux density all increase. Since the magnitude of the iron loss is proportional to the square of the magnetic flux density, the iron loss increases, resulting in overheating of the core. And the increase in magnetic flux causes ...
|
|
Precautions for powering on the inverter after the LS power production holiday
1. During the holiday, low temperature can easily cause the equipment to be damp, check whether the electrical equipment is dry, whether there is moisture and condensation;
2. Check whether the grounding wire is loose and whether the cable is damaged by rodents and insects;
3. Sort out the dust and oil stains, and inverter ...
|
|
Introduction to the matching of LS power inverter loads
1. Square torque load
Fan and pump loads are the most widely used equipment in industrial sites, and frequency converters are used in this type of load. It is a square torque load. In general, inverters with U/f=const control mode can be satisfied with the ...
|
|
Dealing with intermittent shutdown fault measures - power generation
Because the touch of the network adapter is not good, perhaps due to disturbance and other problems, the DP network that has been used for a long time may show a "transient disconnection" situation, that is, it will be disconnected by an occasional moment, and it will soon recover normally. If OB86 is not downloaded, the CPU will stop during a transient outage. Now all over the option to download a ...
|
|
Variable frequency regenerative braking method - LS generates electricity
1. Energy consumption type
This method is to connect a braking resistor in parallel in the DC circuit of the inverter, and control the on/off of a power tube by detecting the DC bus voltage. When the DC bus voltage rises to about 700V, the power tube is turned on, and the regenerative energy is passed into the resistor.
|
|
The difference between multi-function inverter and general-purpose inverter - LS produces electricity
With the deepening of factory automation, the high efficiency and low cost of active warehouses, elevators, transfer systems, etc., as well as the high speed, high efficiency and high precision of small CNC machine tools, kneading and forming machines, textile and film machinery, etc.
|
|
LS Group witnesses the reopening of the "Viet Nam Professional Football League".
The Viet Nam Professional Football League, sponsored by LS Group, began operations in June and is hosted by Viet Nam Professional Football Joint Stock Company. With the comeback of football events such as the Korea K League and the Bundesliga, more and more football events are also brewing to restart.
...
|
|
Elements of LS power inverter operation
1. Physical environment
(1) Temperature factor
Temperature has a huge impact on the lifetime and reliability of the electronic components inside the inverter. When using the inverter in a high operating temperature environment, it is necessary to take additional cooling measures to ensure that the ambient temperature is stable in the inverter.
|
|
LS automatic gain adjustment for power generation
In fact, there are also options for automatic gain adjustment, which generally divide the control response into several levels, such as high echo, medium echo, and low echo, which can be set by the user according to actual needs.
Azimuth Share Buff:
1. Set the share gain of the azimuth ring adjuster;
2 ...
|
|
LS Electric's motion control system solution on pillow (horizontal) packaging machine
The pillow packaging machine mainly performs the operation of product forming, positioning, packaging and sealing, etc., and the equipment is composed of the packaging film shaft that provides the packaging film, the feeding shaft that provides the material, the cutter shaft that performs the sealing and cutting operation and the discharging shaft after the product packaging is completed, and the equipment structure diagram is as follows:
...
|
|
How to operate LS inverters
1. When the power supply is now powered or the inverter is in running condition, do not open the shell of the inverter. Otherwise, an electric shock may occur.
2. When the front cover of the inverter is opened, do not move the inverter. Otherwise, you may be shocked by the high-voltage terminals or exposed charging capacitors. ...
|
|
Introduction to the use of PLC for power production
1. It is used for switching control
The ability of PLC to manipulate switching quantities is very strong. The number of points in and out of the control, less than a dozen points, dozens of points, more can be hundreds, thousands, or even tens of thousands of points, because it can be networked, the number of points is almost unlimited, no matter how many points can be controlled, the control ...
|
|
Automatic adjustment of motor parameters - LS power generation
Step 1: If the motor can be completely separated from the load, in the case of a power failure, the motor is mechanically separated from the load, and the motor is allowed to rotate freely without load.
Step 2: After powering on, select the VFD command source (F0-04) as the command channel of the operation panel.
...
|
|
Introduction to the design of inverter control cabinet - LS power production
The inverter should be installed inside the control cabinet, and the following problems should be paid attention to when planning the control cabinet:
1) Heat dissipation issues:
The heating of the inverter is caused by internal losses. In the inverter, the main circuit is the main circuit for the loss of each part, accounting for about 98%, and the control circuit accounts for 2%. ...
|
|