Selection principles and key points of AC contactors for power production

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

1. The coil voltage of the contactor should generally be lower, so that the insulation requirements of the contactor can be reduced, and it is safer to use. However, in order to facilitate and reduce the equipment, it is often selected according to the actual grid voltage.

2. The operating frequency of the motor is not high, such as compressors, pumps, fans, air conditioners, punches, etc., and the rated current of the contactor is greater than the rated current of the load. The contactor type can be CJl0, CJ20, etc.

3. Counterweight mission motors, such as machine tool main motors, lifting equipment, winches, crushers, etc., have an average operating frequency of more than 100 times/min, and run in starting, jogging, forward and reverse braking, reverse braking, etc., CJl0Z and CJl2 contactors can be selected. In order to ensure the electric life, the contactor can be used to reduce the capacity. When selected, the rated current of the contactor is greater than the rated current of the motor.

                                 Selection principles and key points of AC contactors for power production

Notes:

1. For the main circuit, the change of frequency affects the skin effect, and the skin effect increases when the frequency is high, and for most products, 50 Hz and 60 Hz have little impact on the temperature rise of the conductive circuit.

2. It is necessary to pay attention to the introduction coil, the magnetic flux of the magnet wire used in the 50 Hz planning for the 60 Hz magnet wire will be reduced, and the suction power will also be reduced, and whether it can be used depends on the margin of its planning. Under normal circumstances, the user should use it according to its calibration value, and order according to the operating power frequency used when ordering.

3. The number of operating cycles per hour of the contactor has a great impact on the burning loss of the contact, so attention should be paid to the selection, and the applicable operation frequency is given in the technical parameters of the contactor. When the actual operating frequency of the electrical equipment is higher than the given value, the contactor must be degraded.
More on that
The essence and use of LS power PLC module The essence and use of LS power PLC module

1. What is PLC? PLC control system, Programmable Logic Controller, programmable logic controller, a digital operation of electronic devices specially designed for industrial production planning, it uses a class of programmable memory, used in its internal storage program, the execution of logic...

Switching analysis and synchronous control of inverter - LS power generation Switching analysis and synchronous control of inverter - LS power generation

AC asynchronous motors are widely used in all walks of life, and frequency converters and power frequency power supplies are often required to switch in the selection of frequency conversion speed control system. The primary types of switching are: fault switching and multi-machine system switching. In the process of operation of many production machinery, the motor is not allowed to stop ...

DC reactor for inverter and design calculation - LS power generation DC reactor for inverter and design calculation - LS power generation

The DC reactor for the inverter is also called the flat wave reactor, which is connected in series in the DC bus (terminals P1 and P+). The main thing is to reduce the higher harmonic component of the input current and improve the power factor of the input power supply (to 0.95). This reactor can be used at the same time as the AC reactor, and the inverter has high power ...

LS automatic gain adjustment for power generation LS automatic gain adjustment for power generation

In fact, there are also options for automatic gain adjustment, which generally divide the control response into several levels, such as high echo, medium echo, and low echo, which can be set by the user according to actual needs. Azimuth Share Buff: 1. Set the share gain of the azimuth ring adjuster; 2 ...

The internal accessories component of the power production circuit breaker The internal accessories component of the power production circuit breaker

1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.

Inverter fault handling - LS power generation Inverter fault handling - LS power generation

1. The working temperature of the inverter is high 1. Check whether the ambient temperature of the inverter is too high; 2. Check whether the cooling fan inside the device is working normally; 3. Check whether the ventilation pores and mask grilles are blocked; 4. Check if the load is too heavy. ...

Introduction to inverter self-learning motor - LS power generation Introduction to inverter self-learning motor - LS power generation

1. What is a self-learning motor of inverter? Enter the motor nameplate (voltage, current, Hz rating) in the inverter parameters, and then the inverter actively measures other parameters of the motor. Second, why should the inverter learn by itself?

Analysis of the fault problem of LS power terminal block Analysis of the fault problem of LS power terminal block

From the point of view of application, the function of the terminal block should be achieved: it is necessary to conduct the local conduction of the touch part, and the touch is reliable. The insulating part should not be conducted, and it is necessary to insulate it firmly. There are three common forms of fatal problems in terminal blocks: ...

The size of the contactor is selected by the type of contactor - LS produces electricity The size of the contactor is selected by the type of contactor - LS produces electricity

1. Select the corresponding category of contactor according to the control object, operation times and application category of the contactor. 2. Select according to the rated voltage of the line at the application location. 3. Select the rated current of the main contact of the contactor according to the load capacity. 4. About the voltage level of the lead coil ...

Grounding of the secondary side of the voltage transformer and the current transformer - power generation Grounding of the secondary side of the voltage transformer and the current transformer - power generation

1. The transformer is grounded twice It refers to the grounding of the S2 terminal of the current transformer or the ground of the n terminal of the voltage transformer. As long as the single point is grounded, because the transformer is blocked between the second and the first, before grounding, the secondary winding has no potential connection with the ground, after grounding, the transformer ...

LS power converter interference phenomenon LS power converter interference phenomenon

1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly; 2. Use the inverter to control the water supply, the pressure transformer is used as the signal to collect the pressure, and the pressure transformer is disturbed by the inverter; 3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently; 4. Pressure transformer (4-20 ...

Precautions for the coordination of inverter and PLC - LS produces electricity Precautions for the coordination of inverter and PLC - LS produces electricity

As an alternative to traditional relays, PLC is widely used in various fields of industrial control. Because the PLC can be used to change the control process with software, and has the characteristics of small size, sensitive assembly, simple programming, strong anti-disturbance ability and high reliability, it is especially suitable for operation in harsh environments. ...

Failure analysis of electromagnetic system of LS power production contactor Failure analysis of electromagnetic system of LS power production contactor

(1) The core noise is large: it is normal for the electromagnetic system to produce a slight humming sound during operation, if the sound is too loud or abnormal, it can be judged that the electromagnetic system has a problem, and there are three reasons: (1) Poor contact between the armature and the core or tilting of the armature. After repeated collisions between the touch of the armature and the core, ...

How to troubleshoot the fault of the inverter - the power inverter How to troubleshoot the fault of the inverter - the power inverter

Because the application method is incorrect or the setting environment is unreasonable, the inverter will simply malfunction and cause problems, or the expected operation effect will not be satisfied. In order to prevent problems before they occur, it is important to carefully analyze the cause of the problem in advance. ...

Analysis of heat dissipation problems of inverter - LS power generation Analysis of heat dissipation problems of inverter - LS power generation

In order to use the inverter correctly, it is necessary to consider that the service life of the VFD decreases exponentially with the increase in temperature. This is due to: When the ambient temperature rises by 10 degrees, the service life of the VFD is halved. So pay attention to heat dissipation! When the VFD is working, the current flowing through the VFD is very large, and the VFD emits ...

The cause of the failure of low-voltage electrical appliances - LS power generation The cause of the failure of low-voltage electrical appliances - LS power generation

In the control circuit of low-voltage electrical appliances, there are simple low-voltage components such as: buttons, safe, etc.; There are also slightly messy low-voltage electrical control components, such as circuit breakers, touch devices, time relays, thermal relays and other simple components, which makes it necessary to diagnose and analyze the cause of the problem. ...

A brief description of the K120S series plc A brief description of the K120S series plc

K120S series PLC product is a unit PLC product introduced to the market by LS in 2004, which has laid a solid foundation in the low-end small machinery supporting industry with its high-performance price ratio. Relying on some special functions of the product, it has also won some industry praise. ...

The difference between inverter and servo - LS produces electricity The difference between inverter and servo - LS produces electricity

An important difference between servo and frequency conversion is that frequency conversion can be without encoder, while servo must have an encoder for electronic commutation. 1. What the two have in common: The skill of communication servo itself is the learning and application of ...

Analysis of the problem of excessive current of LS three-phase motor for power generation Analysis of the problem of excessive current of LS three-phase motor for power generation

First, the power supply problem 1. The power supply voltage is too high When the power supply voltage is too high, the motor back electromotive force, magnetic flux and magnetic flux density all increase. Since the magnitude of the iron loss is proportional to the square of the magnetic flux density, the iron loss increases, resulting in overheating of the core. And the increase in magnetic flux causes ...

The cause of motor burnout caused by inverter - LS generates electricity The cause of motor burnout caused by inverter - LS generates electricity

In fact, the problems of the motor are not the cause of the motor itself, most of them are caused by the non-standard debugging of the inverter or the wrong inverter motor when the inverter motor is used, etc., mainly due to the following situations: 1. Put the general motor ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top