LS power generation installs the switching power supply step

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

1. Confirm the location of the device

Before the equipment switches on and off the power supply, it is necessary to confirm the location of the equipment, and generally require the equipment to be in a ventilated, boring, non-corrosive gas and dust-free place.

2. Equipment holder

The fixing base of the switching power supply is fixed on the orientation of the equipment, and the bolts are generally used to fix or the equipment is on the guide rail.

                               LS power generation installs the switching power supply step

3. Connect the input and output cables

Connect the input and output cables to the corresponding terminal blocks, and make sure that the wiring is correct and secure.

4. Grounding treatment

Connect the grounding wire to the grounding terminal to ensure safety and security.

5. Debugging and inspection

After the equipment is completed, it is required to be debugged and inspected, including the inspection of initiation, operation, stability of output voltage and current, etc.

6. Avoid misoperation

In the process of use, it is necessary to pay attention to avoid misoperation and avoid damage or safety accidents caused by the equipment.

More on that
The difference between overload and overcurrent of the inverter The difference between overload and overcurrent of the inverter

(1) The maintenance objectives are different Overcurrent is mainly used to maintain the inverter, whereas overload is mainly used to maintain the motor. Because the capacity of the inverter sometimes needs to be increased by one or even two gears than the capacity of the motor, in this case, the inverter is not necessarily overcurrent when the motor is overloaded. ...

An internal component of LS's power circuit breaker An internal component of LS's power circuit breaker

1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.

Explanation of basic terms of electrician - electricity production Explanation of basic terms of electrician - electricity production

1. Active power - in the process of generating and transmitting alternating current energy, the part of energy used to convert into electromagnetic methods is called active power 2. Reactive power - in the process of AC electric energy generation and transmission, it is used for electromagnetic field AC in the circuit.

LS power production automation subdivision industry service era LS power production automation subdivision industry service era

LS power automation drives are mainly for industrial enterprises and construction enterprises, including municipal, metallurgical, electric power, chemical and other power-oriented industrial enterprises, car, food and beverage, pharmaceutical and other professional enterprises, as well as OEM equipment manufacturing enterprises. ...

LS electric braking unit functions, advantages and operation process LS electric braking unit functions, advantages and operation process

First, the main function of the braking unit In some applications, the need for rapid speed reduction, according to the principle of asynchronous motor, it can be known that if the slip is larger, the greater the torque, the same braking torque will increase with the increase of the speed reduction rate, so that the system speed reduction time is greatly shortened, and the energy feedback is greatly ...

The basic principle of motor protector selection - LS power production The basic principle of motor protector selection - LS power production

The fundamental method of motor protector selection At present, there is no unified standard for motor protectors on the market, and almost every manufacturer has its own type standard. In order to meet the needs of different customers, manufacturers derive many products with different uses, and a wide range of products for the majority of users to choose ...

Energy-saving method of ventilator inverter - LS power generation Energy-saving method of ventilator inverter - LS power generation

high-power Although some inverters are fan type inverters, but it is a low-power fan inverter, such an inverter does not have the effect of energy saving, and it is necessary to achieve energy saving must be a high-power inverter, in addition to the high-power fan inverter, it is necessary to meet its ...

The selection principle of AC contactors - LS produces electricity The selection principle of AC contactors - LS produces electricity

1. The voltage level of the AC contactor should be the same as the load, and the type of contactor should be suitable for the load. 2. The accounting current of the load should be less than or equal to the additional working current of the contactor. The turn-on current of the contactor is greater than the starting current of the load, and the breaking current is greater than the load ...

How LS produces power PLC operation How LS produces power PLC operation

Although many relays, timers and counters are often used in the ladder diagram programs used by LS PLC, LS PLC does not have these hardware physically, but uses memory and program programming methods to make logic control modifications, and connects external machines through output components.

Quickly locate the fault method of switching power supply - LS power generation Quickly locate the fault method of switching power supply - LS power generation

Due to the short circuit of the load, the failure of the self-oscillation circuit and the loss of control of the protection circuit, the switching power supply will cause the base of the switch tube to be unable to get the switching pulse and intermittent operation, which makes it difficult to locate the shortcomings of SMPS. The difficulty of the repair operation and the improper method will expand the shortcomings, constituting the phenomenon of continuous burning of the switch pipe, etc., ...

Inverter circuit structure - LS generates electricity Inverter circuit structure - LS generates electricity

The main circuit is the power replacement part of the power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is to change the DC of the voltage source to the communication of the DC port of the inverter, and the filter is the capacitor. The current type is to change the DC of the current source to the communication ...

Brake unit, brake resistor function - LS generates electricity Brake unit, brake resistor function - LS generates electricity

Brake unit: The function of the braking unit is to turn on the energy-dissipating circuit when the voltage Ud of the DC circuit exceeds the specified limit (such as 660V or 710V), so that the DC circuit can release energy by thermal energy after passing through the braking resistor. The braking unit can be divided into built-in and external, the former is ...

LS power production contactor application LS power production contactor application

LS touchers are divided into AC touchers (voltage AC) and DC touchers (voltage DC), which are used in electricity, power distribution and consumption. Toucher broadly refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field in industrial electricity, so that the contacts are closed, so as to control the load. ...

Why can't the inverter be equipped with a leakage protector? Why can't the inverter be equipped with a leakage protector?

When using an inverter, a leakage maintainer must not be used. This is a major criterion for the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...

Contactors play a role in industrial electricity Contactors play a role in industrial electricity

The contactor is an automatic switch for industrial roofs to control its on/off with a button. The contactor consists of an electromagnetic coil, a static armature, a moving armature, a static contact, a moving contact and a fixing bracket. The principle is that when the electromagnetic coil of the contactor is connected to the communication electricity, a strong magnetic field will be generated to make the center of the coil ...

Introduction to the control method of LS power inverter Introduction to the control method of LS power inverter

Inverter control method: low-voltage general frequency conversion output voltage is 380-650V, output power is 0.75-400kW, operating frequency is 0-400Hz, and its main circuit adopts AC-DC-AC circuit. Its control methods have gone through the following five generations. 1U/f=C sine pulse width modulation ...

LS power inverter function LS power inverter function

1. Soft up The direct launch of the inverter motor has a serious impact on the power grid, and it will also have too high requirements for the capacity of the power grid, which is extremely unfavorable to the service life of equipment and power grid circuits. After the use of inverter to save energy, the use of inverter's speed regulation (V/F) function will make the starting current from a small ...

DC reactor for inverter and design calculation - LS power generation DC reactor for inverter and design calculation - LS power generation

The DC reactor for the inverter is also called the flat wave reactor, which is connected in series in the DC bus (terminals P1 and P+). The main thing is to reduce the higher harmonic component of the input current and improve the power factor of the input power supply (to 0.95). This reactor can be used at the same time as the AC reactor, and the inverter has high power ...

The difference between LS power inverter and servo The difference between LS power inverter and servo

An important difference between servo and frequency conversion is that frequency conversion can be without encoder, while servo must have an encoder for electronic commutation. 1. What the two have in common: The AC servo technology itself is to learn and apply the technology of frequency conversion, and the servo control of the DC motor is based on the ...

Manufacturing Automation Terminology – LS Electricity Generation Manufacturing Automation Terminology – LS Electricity Generation

I/O Points: When discussing control systems, I/O points are a term that is often heard. It refers to the input/output point, I stands for INPUT, which refers to the input, and O stands for OUTPUT, which refers to the output. The inputs/outputs are for the control system, and the input refers to the ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top