Pilz: Don't underestimate the authorization key, it can make a big difference!

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

With the increasing functional requirements of industrial production, the continuous optimization of process levels and the escalation of the complexity of production conditions, systems that effectively record and manage relevant data are particularly important for machine safety, especially for production safety.

PITreader Authorization Management System

THE PITreader entitlement management system from PILZ is a comprehensive secure access protection system that covers rights management, safety interlocking, guard locking and information display functions. The authorization management system can identify and judge the permission data written by the RFID electronic key, and complete the corresponding authorization management based on the permission data, so as to help users complete tasks related to plant and machine access rights.
Pilz: Don't underestimate the authorization key, it can make a big difference!
  PITreader supports Modbus/TCP communication and REST APIs, and each RFID key has its own "unique" security signature. The authority key is divided into pre-configured keys 1 to 5 and custom keys, and the host computer can read the data to realize the functions of authority management, blacklist list, event traceability, etc., effectively improving the management ability of production and operation.

Diverse key options

As the new RFID authorization management product of the Identification and Access Management (I.A.M), the industrial identification and access management family, PITreader can support a wide variety of electronic keys to meet the diverse needs of customers:

● PITreader key—A regular PITreader key

● PITreader sticker—The small round patch key in the image below

● PITreader card—The card key in the image below
Pilz: Don't underestimate the authorization key, it can make a big difference!
  As of firmware version 2.1, PITreader will support ISO 14443-A – the standard for contactless IC cards. The PITreader authorization management system can perform many different functions by writing the program: for example: allowing access permissions, allowing HMI operation, adding/removing authorized personnel, key exchange system to prevent accidental start-up, and key exchange system - manual operation permissions, etc.

Security & Safety's "Flying with Wings"

Nowadays, machinery safety has been deeply rooted in the hearts of the people, and with the further advancement of intelligent manufacturing, the importance of information security to production safety is self-evident. As a specialist in safety automation technology, Pilz is able to provide holistic solutions that cover information security and machinery safety according to customer needs, ensuring the safety of personnel and equipment at the same time.

The PITreader authorization management system supports the writing and granting of multiple permissions, and its comprehensive functions such as the collection of production line-related data are also becoming more and more perfect, which can well meet the relevant safety and production needs of the factory.

More on that
Pilz offers a new service called "Machinery Safety Assessment" (MSE). Pilz offers a new service called "Machinery Safety Assessment" (MSE).

Automation specialist Pierz is now offering a new service, the Machinery Safety Assessment (MSE), to assess the machinery safety of existing machines. Data reports provide operators with a simple and quick overview of the safety and compliance status of their machines. Pilz provides a comprehensive risk assessment in its portfolio of services.

Peel magnetic relays - what are the connection methods of relays? Peel magnetic relays - what are the connection methods of relays?

1. 3-pin relay wiring The common 3-pin relay is the car horn relay. No. 1 is the contact terminal, which connects the load; No. 2 is the common terminal between the contact and the coil, which is connected to the power supply; No. 3 is the coil terminal, which connects the button switch (such as the horn on the steering wheel).

Pilz: New system version PSS 4000 1.24 Pilz: New system version PSS 4000 1.24

The automation system PSS 4000 offers new features in the new version 1.24. Here's what you need to know:   New data types FIXED and LFIXED The data types FIXED (a fixed digit with 6 decimal places) and LFIXED (a fixed number with 11 decimal places) are now ...

Peel magnetic relay - how to adjust the voltage of high and low voltage relays? Peel magnetic relay - how to adjust the voltage of high and low voltage relays?

1. Determine the voltage range that needs to be regulated: First of all, you must clarify the voltage range you need to regulate, as well as the specifications of the high and low voltage relays and the voltage range that can be adjusted. If there is no clear scope and specifications, you can check the relevant manuals of high and low voltage relays or consult the equipment manufacturer.

Peel magnetic relay - the wiring method, function and application of time relay Peel magnetic relay - the wiring method, function and application of time relay

Wiring method of time relay 1. Control wiring You think of it as a DC relay. 3. 7 is used to connect to 12V control voltage; 2. 7 is used to connect to 24V control voltage. 7 of them are used as the negative electrode of direct current, which is connected to the neutral line when used. 2. Connect to a 220V live wire. 2 ...

REPAIR OF PILZ SAFETY RELAYS REPAIR OF PILZ SAFETY RELAYS

AS MENTIONED EARLIER, PILZ SAFETY RELAYS ARE THE MAIN COMPONENTS FOR CONTROL CIRCUITS AND MONITORING AND PROTECTION SYSTEMS FOR ELECTRIC LOCOMOTIVES. When the locomotive is running, when the motor, electrical appliances or connection lines in the main circuit and auxiliary circuit fail, the fault can be replaced by the Pilz safety relay of the corresponding monitoring and protection system.

Peel magnetic relay - relay common faults and solutions Peel magnetic relay - relay common faults and solutions

First, the contact is loose and cracks The contact is the electrical touch part of the relay to complete the switching load, and the contact of some products is riveted and pressed, and its primary disadvantage is that the contact is loose, the contact cracking or the scale azimuth error is too large. This will affect the touch reliability of the relay. ...

Piermagnetic switches – an introduction to the functions of safety switches Piermagnetic switches – an introduction to the functions of safety switches

1. When the load exceeds the action current, the circuit will be automatically cut off; 2. After the circuit is automatically cut off, the panel indicator light is on, which is convenient for the judgment of the fault part; 3. After troubleshooting, press the red button at the bottom of the panel to restore the normal power supply; 4. For other reasons, the shell ...

Introduction to the principle and application of Pilz ground proximity switches Introduction to the principle and application of Pilz ground proximity switches

The Pilz safety proximity switch also belongs to a position sensor with a switching output, its measuring head is usually a plate that constitutes a capacitor, and the other plate is the object itself, when the object moves towards the proximity switch, the dielectric constant of the object and the proximity switch changes, so that ...

Peel magnetic relay – the role of intermediate relays Peel magnetic relay – the role of intermediate relays

1. Replace small contactors: the contacts of the central relay have a certain ability to carry load, and when the load capacity is relatively small, it can be used to replace the use of small contactors, such as electric roller shutters and the control of some small household appliances. This not only serves the purpose of control, but also saves space, ...

Pierre Magnetic Switches – What are the functions of safety door switches? Pierre Magnetic Switches – What are the functions of safety door switches?

1. The security door can also be called the anti-theft door, and the safety door switch, as the name suggests, is an automatic inductive control switch to ensure the safety of the door, and the opening and closing of the door needs to be detected by it to open and close. For example, this kind of safety door switch will be used in the community or factory, traffic, etc., which is conducive to monitoring ...

The main anti-shielding measures of Pilz safety switches The main anti-shielding measures of Pilz safety switches

1. Physical location of the installation – "out of reach or out of sight" Consider installing the component in a place that is out of the reach of personnel, or directly outside the interlock switch as a protective cover to prevent disassembly or movement, as shown in the figure, whether it is a mechanical interlock on the left, or a non-...

How to match the user's drive circuit with the input characteristics of the solid state relay How to match the user's drive circuit with the input characteristics of the solid state relay

Generally speaking, the input control voltage of the solid state relay is 3.2-32V. The control current is 5-30mA.Usually the SSR input circuit of 1-2 is not a constant current source circuit, and the input control voltage is 4-16V. The control current is 5-20mA, and the SSR input circuit with the larger rated current is connected to the constant current source ...

Pierre Switches – An introduction to the basics of safety switches Pierre Switches – An introduction to the basics of safety switches

Features of the safety door switch: The safety gate switch is composed of two independent parts: the switch body and the operating part of the switch. When the safety door is opened, the switch actuator is pulled out of the switch body and the normally closed contacts in the switch are disconnected by a mechanical rebound device. While...

Peel magnetic relays - analysis of common faults and causes of relays Peel magnetic relays - analysis of common faults and causes of relays

1. Contact failure (1) The phenomenon that cannot be disconnected due to mechanical occlusion of the contact (the needle-like protrusion and pit formed on the contact bite each other), fusion welding, or cold welding. (2) The contact wear of the relay is caused by the absence of arc extinguishing devices or measures, or improper parameter selection, ...

Pierre Servo Amplifiers – What are the basic requirements for servo amplifiers? Pierre Servo Amplifiers – What are the basic requirements for servo amplifiers?

Requirements for servo feed systems 1. Wide range of speed regulation 2. High positioning accuracy 3. There is sufficient transmission rigidity and high speed stability 4. Fast response, no overshoot In order to ensure productivity and processing quality, in addition to the requirement of high positioning accuracy ...

Pilz safety switches – how to install safety switches Pilz safety switches – how to install safety switches

1) The installation of the switch panel should be after the installation of the lamp, and the switch must be connected in series on the live line; Application of sealed or protected sockets in wet locations; The allowable deviation of the verticality of the panel is not more than 1mm; The gap between the panels installed in rows should not be greater than 1mm. 2) Where the socket must be facing the switch panel ...

Pierre Servo Amplifier - Introduction to the advantages of servo amplifiers Pierre Servo Amplifier - Introduction to the advantages of servo amplifiers

Single-phase servo amplifier (referred to as amplifier), with a variety of quarter-turn, linear stroke, multi-turn single-phase electric actuator (electric actuator) matching, widely used in industrial automation control process in the automatic adjustment system, this amplifier is an improvement of the traditional amplifier, compared with the traditional ...

Pierz exhibited star products at the SIAF Guangzhou Automation Exhibition Pierz exhibited star products at the SIAF Guangzhou Automation Exhibition

At the SIAF Guangzhou Automation Exhibition, which opened on March 10th, Pilz once again brought new automation solutions to visitors under the concept of "WeAutomate Safely". The exhibition ...

Pilz won the China Machinery Industry Science and Technology Award Pilz won the China Machinery Industry Science and Technology Award

Recently, Pilz won the China Machinery Industry Science and Technology Award jointly issued by the China Machinery Industry Federation and the China Mechanical Engineering Society, in recognition of Pilz in the "Machinery Safety Hazardous Energy Control Method Locking/Listing (GB/T33579-2017 Standard Number) Standard Formulation, Application and Publicity...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top