(1) Whether the closing condition of the isolation switch is not defective, and whether there is any failure or dislocation;
(2) The porcelain insulation of the isolation switch should be free of defects, no cracks, no discharge phenomena and flashover traces;
(3) Contact inspection: a. Check whether the contact surface of the contact is dirty, deformed and corroded, and whether the contact is crooked; b. Check whether the contact spring or spring blade is broken; c. Check whether the contact has any heating and redness caused by poor contact.
(4) Whether there is rust or damage to the operating connecting rod and tissue parts, whether the parts are consolidated, and whether there are abnormal phenomena such as looseness, skewedness, and falling;
(5) Regarding the grounding isolation switch, check whether the ground knife is tight, whether the grounding is excellent, and whether there is cracking in the visible part of the grounding body;
(6) Check whether the anti-mistaken locking device is excellent.
|
More on that
|
Frequency converter and PLC connection problems - Schneider
When the inverter is used to form an automatic control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system.
1.PLC switch ...
|
|
Precautions for external wiring of the inverter
In the process of connecting the line of the inverter, it is necessary to pay attention to the following aspects:
1. The power supply must be connected to the main circuit power terminal L1/R, L2/S, L3/T, if the power supply is connected to other terminals by mistake, the inverter will be damaged.
2. It is necessary for the grounding terminal to be well connected.
|
|
Schneider inverter motor control mode
Fundamentals of magnetic flux vector manipulation
The control of a three-phase asynchronous motor is much more complicated than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating.
However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...
|
|
Schneider low-voltage circuit breaker selection
1. Determine the type and maintenance situation of Schneider circuit breaker according to the maintenance requirements of the line, and determine the selection of frame type, device type or current limiting type. Generally speaking, the Schneider frame circuit breaker can break the short-circuit current with a large device type and a large volume. Usually, the branch line chooses ...
|
|
Servo motor selection process – Schneider
1. Load organization (acknowledging the type of tissue and its specific data, such as ball screw length, ball screw diameter, stroke, pulley diameter, etc.)
2. Form of action (acknowledging the form of action of manipulating the target, the relationship between time and speed; Will manipulate ...
|
|
Schneider instrumentation maintenance precautions
1. When assembling and adjusting the appearance, the original position should be recorded for rehabilitation.
2. When repairing the appearance of precision instruments, if you accidentally bounce small parts away, you should first determine the position where you can fly down.
|
|
The upper and lower frequency parameters of the inverter - Schneider
The output frequency of the inverter set by the user according to the needs of the production process. For example: the original power frequency power supply of the fan motor is now transformed into frequency conversion speed regulation, you can set the given frequency to 50 Hz, and there are two ways to set it: one is to use the operation panel of the inverter to input the digital quantity of the frequency 5 ...
|
|
The difference between vector inverter and general-purpose inverter - Schneider
There are two main differences between vector inverters and general-purpose inverters. One is high control accuracy, and the other is high output torque at low speed.
Vector special inverter:
The operating principle of the vector special inverter is to carry out inverter after rectification, ...
|
|
Schneider intermediate relays
Schneider 24VDC intermediate relays are the most common components in control systems. Generally, 2 normally open and 2 normally closed are the most commonly used, but sometimes 4 normally open and 4 normally closed contacts are not enough. Both have different coil and base models.
...
|
|
Calculation method of inverter capacity - Schneider
1. Accounting of inverter capacity when the load is continuously changed periodically
In many cases, the load of the motor changes periodically. Obviously, in this case, picking the capacity of the inverter according to the minimum load will be overloaded, and it will be uneconomical to select according to the maximum load.
|
|
Schneider automatic control instrument construction content and procedures
1. Construction preparation. Including the preparation of operating conditions (construction skills documents and detailed design documents), construction organization design, equipment list, data budget, and list of machined parts;
2. Cooperate with civil engineering majors to do a good job of pre-embedding and reserving work;
3. Cooperate with process equipment, ...
|
|
Schneider inverter motor control mode
Fundamentals of magnetic flux vector manipulation
The control of a three-phase asynchronous motor is much more messy than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating.
However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...
|
|
The difference between Schneider and Siemens PLC
There are three main differences, namely: different uses, different products, and different characteristics.
1. Different use cases: The programmable manipulator produced by Siemens in Germany is also widely used in China, and has been used in metallurgy, chemical industry, printing production lines and other fields.
|
|
Frequency characteristics of frequency converters – Schneider
a. Output frequency scale. The output frequency scale that can be controlled by the general inverter, the lowest starting frequency is generally 0.1Hz, and the highest frequency varies according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it depends on the scale of the high-frequency inverter.
...
|
|
A brief description of the working principle of Schneider power soft starter
Schneider ATS48 soft starter is composed of three opposite parallel thyristors, which are connected in series between the three-phase power supply and the motor, by changing the trigger angle of the thyristor gate pulse, the conduction angle of the thyristor gradually increases from zero, according to the pre-set soft starter parameter curve, the motor output torque ...
|
|
Schneider Multi9 Series C120L Problem
1. What are the characteristic curves of Schneider Multi9 series C120L?
C/D curves.
2. What is the rated current level of Schneider Multi9 series C120?
63A、80A、100A、125A。
3. What is the weight of Schneider Multi9 series C120?
1P:205 ...
|
|
The inverter controls the speed of the AC motor – Schneider
Most of the motors used in the industry are of this type. The rotational speed of an induction AC motor (henceforth referred to as a motor) is approximately determined by the number of poles and frequency of the motor. The number of poles of the motor is fixed by the working principle of the motor. Since the pole ...
|
|
Maintenance of Schneider circuit breakers
In order to keep the main Schneider circuit breaker in excellent operating condition, it is necessary to strengthen the maintenance management.
1. Insist that the air is moist or unclean, and the pipes are not clean, may have the following consequences:
(1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the action of electric arc, which damages the ...
|
|
The UPS boot panel does not show that the UPS is not working - Schneider
Problem: After the UPS is turned on, there is no display on the panel, and the UPS does not work
Problem analysis: Judging from the problem phenomenon, the problem lies in the mains input, the battery and the mains detection part and the battery voltage detection loop:
1. Check ...
|
|
Schneider instrumentation accuracy
It refers to the degree to which the average value measured repeatedly under certain test conditions is consistent with the true value, which is indicated by error. It is used to indicate the magnitude of the error in the system. In practice, control tests are generally carried out with standardized substances or normative methods, and when there are no standardized substances or normative methods, it is often used to add ...
|
|