The output frequency of the inverter set by the user according to the needs of the production process. For example, the original power frequency power supply fan motor is now transformed into frequency conversion speed regulation, and the given frequency can be set to 50 Hz, and there are two ways to set it: one is to use the operation panel of the frequency converter to input the frequency of the digital 50; The other is to adjust with an externally given (voltage or current) signal from the control terminal, most commonly through an external potentiometer.

                              The upper and lower frequency parameters of the inverter - Schneider

The output frequency is the frequency of the actual output of the inverter. When the load of the motor changes, in order to stabilize the drag system, the output frequency of the inverter will be continuously adjusted according to the system condition. Hence the output frequency is frequently changed around a given frequency. From another point of view, the output frequency of the inverter is the operating frequency of the entire drag system.

The upper and lower frequencies refer to the highest and lowest frequencies of the inverter's output, which are usually indicated by fH and fL. According to the different loads carried by the drag system, sometimes the maximum and minimum speed of the motor should be constrained to ensure the safety of the drag system and the quality of the product. In addition, the frequency is too high or too low due to the misoperation of the operation panel and the maloperation of the external command signal, and the upper and lower frequency can be set to maintain the effect.

More on that
Precautions for the selection of Schneider molded case circuit breaker Precautions for the selection of Schneider molded case circuit breaker

1. Shell current and rated current The size of the shell current is 100 (rated current 16 25 32 40 63 80 100) 250 (rated current 160 250 400 (rated current 250 400) 630 (rated current 630A.) ...

Power wiring requirements for Schneider PLC Power wiring requirements for Schneider PLC

The power supply of the DPLC should be taken from the trunk line with a relatively stable voltage or the special line led by the bus of the substation to ensure the voltage quality of the PLC. If the voltage fluctuates too much, consider installing a voltage regulator or uninterruptible power supply (UPS). 2. The power cord is best to use twisted pair, and its cross-sectional area should not be less than 2 square millimeters.

Schneider switch socket authenticity Schneider switch socket authenticity

1. In terms of logo, the logo of the product is a sign of identity, so the genuine products will be very exquisite. The imitation is not very well handled on the logo, the plane contrast above the letter "A" is narrow, and even the top is directly pointed. We must pay attention to this point. 2. From ...

Schneider power supply configuration UPS backup battery method Schneider power supply configuration UPS backup battery method

In order to ensure that the APCUPS power supply can continue to provide high-quality power to the computer in the event of a power outage, it is particularly important to equip the battery backup battery. When the frequency load does not agree to be supplied with power, the backup time of the UPS battery in the communication room should be greater than the time from the suspension of the mains power to the recovery or until the generator set is normal.

Fault check steps for frequency converters - Schneider frequency converters Fault check steps for frequency converters - Schneider frequency converters

1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is running normally, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in the operating state, and do the corresponding recording work; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...

Inverter maintenance mantra method - Schneider Inverter maintenance mantra method - Schneider

Don't worry about the damage of the frequency conversion, disassemble the machine after the discharge; It is indispensable to ask for a diagnosis and clarify the problem at the beginning of the test; Input and output PN junction, three-phase balance and then unshelling; Look at the nameplate before powering on, the wrong voltage will blow up; The bus has no electricity to see that it is safe, and the rectifier filter is wrong ...

Is there still an output after the UPS power is turned off? Is there still an output after the UPS power is turned off?

1. After the UPS power supply is shut down, the output terminal is still powered, but the UPS power supply does not play a role at this time, and it is in a bypass state. 2. The power supply will not be cut off after the UPS power supply is shut down, because the UPS power supply will go bypass after the shutdown, there is still a mains power input at this time, ...

Schneider Multi9 Series C120L Problem Schneider Multi9 Series C120L Problem

1. What are the characteristic curves of Schneider Multi9 series C120L? C/D curves. 2. What is the rated current level of Schneider Multi9 series C120? 63A、80A、100A、125A。 3. What is the weight of Schneider Multi9 series C120? 1P:205 ...

Schneider UPS power supply installation steps Schneider UPS power supply installation steps

UPS power supply is widely used in shopping malls, supermarkets, banks and other enterprises and institutions, the primary effect of the power supply is to provide continuous power supply for the unit in the state of power failure, so as to ensure the normal operation of the computer network system and other application systems, and effectively avoid data loss. In the power supply ...

Schneider relay model introduction Schneider relay model introduction

RM4 Series Control Relay (Three-phase Power Control) RM4 series voltage steerable relays RM4 current operated relay RM4 level control relay RM17 three-phase power controller RM35 3-phase power control relay RM17 Voltage Steerable Relay ...

Circuit breaker failure protection - Schneider Circuit breaker failure protection - Schneider

Circuit breaker failure maintenance refers to the relay maintenance action of faulty electrical equipment when the trip command is announced and the circuit breaker refuses, the maintenance action information of the faulty equipment and the current information of the rejected circuit breaker constitute the judgment of circuit breaker failure, and other related problems in the same plant and station are cut off in a shorter time limit.

The reason for the frequent tripping of Schneider leakage switches The reason for the frequent tripping of Schneider leakage switches

1. Defective device The lead wire of each pile head is not firmly connected and loosened for a long time, which will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, forming undervoltage of the line, and the air switch action. 2. The leakage switch does not match the load The actual electricity load of the home is large ...

Switching power supply circuit fault phenomenon - Schneider Switching power supply circuit fault phenomenon - Schneider

1. The power supply voltage of the secondary load is 0V. There is no response after the inverter is powered on, there is no indication on the operation display panel, and the 24V and 10V voltages of the measurement and control terminals are 0V. Check that the charging resistance or pre-charging circuit of the main circuit is correct, which can be identified as a switching power supply fault. The overhaul process is as follows: 1 ...

AC-DC inverter composition and function - Schneider AC-DC inverter composition and function - Schneider

The AC-DC inverter main circuit consists of three components: the rectifier main circuit, the center circuit and the inverter circuit. 1. The main circuit is the power replacement part that provides voltage regulation and frequency regulation power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is the voltage source ...

Inverter selection and capacity matching - Schneider Inverter selection and capacity matching - Schneider

In addition, it is unscientific to select the inverter body alone, without considering whether the inverter selection and capacity matching are appropriate. ...

Schneider Modicon M100 Programmable Controller Features and Benefits Schneider Modicon M100 Programmable Controller Features and Benefits

The Schneider Electric Modicon M100 programmable controller is part of the Easy Series and is suitable for simple I/O logic control machines. characteristic AC power supply High-speed processor with 0.2μs/boolean amount Built-in a ...

Features of Schneider elliptical gear flowmeter Features of Schneider elliptical gear flowmeter

Elliptical gear flowmeter (also known as displacement flowmeter, gear flowmeter), classified as a positive displacement flowmeter, is a class with high accuracy in the flow surface. It uses a mechanical measuring element to continuously cut the fluid into a single known volume part, and according to the measuring chamber, it is repeated and repeated.

Features of Schneider explosion-proof inverter box Features of Schneider explosion-proof inverter box

1. Aluminum alloy shell or steel plate welding, surface spraying; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; 3. It is mainly adjusted by changing its output frequency to adjust the speed of ordinary three-phase asynchronous motor, so as to reach the production process.

Introduction to the core knowledge and application of instrumentation - Schneider Introduction to the core knowledge and application of instrumentation - Schneider

Although the "measurement and control skills and instruments" category of majors touch the fields of national defense, aerospace, aviation, sailing, railway, machinery, light industry, chemical industry, electronics, electric power, telecommunications, metallurgy, petroleum, mining, geology, surveying and other industrial, agricultural and scientific research categories, the Ministry of Education has a special understanding of "measurement and control skills and instruments".

Inverter trip protection circuit – Schneider Inverter trip protection circuit – Schneider

After the maintenance function of the inverter is caused by the operation of the problem, it will trip immediately, and the fault code will be displayed together, and the tripping alarm indication circuit of the peripheral inverter will send out an audible and visual alarm to remind the operator to clean up the problem in time. Inverter hopping ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top