The quality of the control circuit determines the function of the LS inverter.
The function of the DC central circuit is to smooth the output of the rectifier circuit to ensure that the inverter circuit and the control power supply can obtain a high-quality DC power supply. When the rectifier circuit is the voltage source, the primary component of the DC central circuit is a large-capacity electrolytic capacitor, and when the rectifier circuit is the current source, the lubrication circuit is mainly composed of a large-capacity inductor. In addition, due to the need for motor actuation, braking resistors and other auxiliary circuits are sometimes included in the DC center circuit.
The inverter circuit is one of the most important parts of the LS inverter. Its primary function is to convert the DC power output of the lubricating circuit into an AC power supply with arbitrary adjustable frequency and voltage under the control of the control circuit. The output of the inverter circuit is the output of the LS inverter, which is used to realize the speed control of the asynchronous motor.
The control circuit of LS inverter includes several parts, such as the main control circuit, signal detection circuit, gate (base) drive circuit, external interface circuit and maintenance circuit, which is also the core part of the inverter. The quality of the control circuit determines the quality of the function of the inverter.
The primary function of the control circuit is to send various signals obtained by the detection circuit to the operation circuit, so that the operation circuit can supply the necessary gate (base) driving signal for the main circuit of the inverter according to the requirements, and provide the necessary maintenance for the LS inverter and the asynchronous motor. In addition, the control circuit also receives/transmits various forms of external signals and gives the internal working conditions of the system through external interface circuits such as A/D, D/A, etc., so that the inverter can cooperate with external equipment for various high-performance controls.
|
More on that
|
LS inverter frequency conversion mode
1. The operator panel is given The operator panel is a simple frequency setting method of the inverter, and the user can directly change the set rate of the inverter through the potentiometer, digital key or rising and descending keys on the inverter operator panel. The big advantage of the operator panel is that it is simple ...
|
|
The advantages of the inverter in practical application - LS power generation
With the continuous progress of industrial automation, inverters have also been widely used, energy conservation and environmental protection as the core of China's industrial economy, in the direction of the sustainable development of China's industry, but also useful to promote the sustainable development of China's inverter profession, so that I ...
|
|
Introduction to the matching of LS power inverter loads
1. Square torque load
Fan and pump loads are the most widely used equipment in industrial sites, and frequency converters are used in this type of load. It is a square torque load. In general, inverters with U/f=const control mode can be satisfied with the ...
|
|
LS power converter interference phenomenon
1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly;
2. Use the inverter to control the water supply, the pressure transformer is used as the signal to collect the pressure, and the pressure transformer is disturbed by the inverter;
3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently;
4. Pressure transformer (4-20 ...
|
|
LS Group witnesses the reopening of the "Viet Nam Professional Football League".
The Viet Nam Professional Football League, sponsored by LS Group, began operations in June and is hosted by Viet Nam Professional Football Joint Stock Company. With the comeback of football events such as the Korea K League and the Bundesliga, more and more football events are also brewing to restart.
...
|
|
Recommended models for power production contactors
GMC-6 Contactor GMC-6 Rated voltage: 110V/22OV/380V;
GMC-9 Contactor GMC-9 Rated voltage: 110V/22OV/380V;
GMC-12 Contactor GMC-12 Rated voltage: 110V/22OV/380V;
GMC-18 Contactor GMC-18 Rated voltage 110V/ ...
|
|
Meaning and classification of LS Electronic Motor Relay (EMPR).
The Electronic Motor Relay (EMPR) is a digital motor maintenance relay with an MCU that has a compact and compact form factor that can be combined directly with a contactor. Through the implementation of real-time data processing, high reliability and high precision can be completed, and it can pass through phase loss, reverse, unbalance, stalled rotor, connection...
|
|
LS power terminal is faulty
From the perspective of application, the function of the terminal block should be achieved: the contact part should be conducted, and the contact should be reliable. The insulating parts should not be conducted, and it is necessary to insulate them firmly. There are three common forms of fatal failure of terminal blocks:
...
|
|
The inverter selects the appropriate peripheral equipment - LS power generation
After we have selected a suitable Variable-frequency Drive (VFD), we also need to consider whether we need to equip other peripheral equipment according to the actual situation of the site. The peripheral equipment selected by VFD mainly includes circuit breakers, reactors, contactors, braking resistors, etc.
...
|
|
Interference phenomenon that often occurs in LS power inverters
1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly;
2. In the water supply controlled by the inverter, the pressure transformer is used as a signal to collect the pressure, and the pressure transformer is disturbed by the inverter;
3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently;
4. Pressure transformer (4-20 ...
|
|
Inverter overvoltage alarm analysis - LS power generation
Change the shutdown mode to inertia parking and you're done! In this way, after the fan is stopped, the inverter will immediately turn off the output, so that the fan can stop freely, at this time, although the fan is in the power generation situation, but the electricity generated by the fan will not pass through the inverter of the inverter to generate direct current, so the inverter will not overvoltage ...
|
|
LS Electric reached a strategic cooperation with Nandu Power Supply and Changzhou Kunlan
Due to the "new infrastructure" policy, the Chinese government has vigorously promoted the new energy and ESS markets, and according to CNESA, the cumulative electrochemical energy storage scale in China will reach 19.3GW in 2023, which is expected to exceed 20% of the global market.
June 3 ...
|
|
Inverter harmonic calculation method - LS power generation
1. Method 1
Method 1: Fourier transform to obtain the amplitude and phase of each harmonic of voltage and current, calculate the active power of each harmonic according to P=√3UIcosφ, and add the active power of all harmonics to obtain the harmonic power.
Method 2: Measure the total active work ...
|
|
Wiring method of the main circuit of the inverter - LS power generation
1. The power supply should be connected to the R, S, and T terminals of the VFD, and should not be connected to the VFD (U, V, W), otherwise the VFD will be damaged. It is necessary to clean up the trivial parts of the wire head after wiring, which may lead to abnormalities, failures, and failures, and it is necessary for the VFD to always be clean. When punching holes in the console, note that ...
|
|
The working principle of the LS power production module
When the LS power generation module is put into operation, its working process is generally divided into three stages: input sampling, user program fulfillment, and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the upper ...
|
|
Introduction of LS power inverter governor
Frequency conversion governor is the power frequency power supply (50Hz or 60Hz) into various frequencies of communication power supply, in order to complete the variable speed operation of the motor equipment, during which the control circuit completes the control of the main circuit, the rectifier circuit converts the communication power into direct current, and the output input of the DC center circuit to the rectifier circuit ...
|
|
Cycloidal reducer transmission system testing - LS power production
With the support of data processing, signal analysis and computer skills, the transmission system uses dynamic error detection equipment, starting from the measurement of time domain error information, and the internal dynamic test of the transmission system should include the following aspects.
...
|
|
Basic introduction to transistors - LS produces electricity
A transistor is a solid-state semiconductor device with a variety of functions such as detection, rectification, amplification, switching, voltage regulation, and signal modulation. A transistor is a variable current switch that can manipulate the output current based on the input voltage. Unlike general mechanical switches (e.g. Relay, swit...)
|
|
Selection principles and key points of AC contactors for power production
1. The coil voltage of the contactor should generally be lower, so that the insulation requirements of the contactor can be reduced, and it is safer to use. However, in order to facilitate and reduce the equipment, it is often selected according to the actual grid voltage.
2. The operating frequency of the motor is not high, such as compressor, water pump, air ...
|
|
Asynchronous motor with inverter - LS generates electricity
Before the asynchronous motor is equipped with an inverter, let's take a look at the three major types of mechanical equipment loads:
1. Constant torque load: such as conveyor belts and mixers; When the inverter drags a load of constant torque nature, the torque at low speed should be large enough and the overload capacity should be large enough. If you need ...
|
|