1. The load is too heavy, the load carried by the motor is too heavy, or in other words, the resistance torque of the production machinery exceeds the additional torque of the motor.
2. Use improper overload, for example, increase the operating frequency of the inverter to the extra frequency of the motor, and when the motor runs above the extra frequency, it will enter the constant power operation area, and its useful torque decreases with the rise of frequency, when the useful torque is less than the load torque, the motor is overloaded.
3. Improper overload of functional preset, for example, a production machine is in a light load state, the operating frequency is very low, and the torque increase (U/f ratio) is preset too large, resulting in "overload" due to magnetic circuit saturation during low-frequency operation.
4. The voltage on the motor side is too low
(1) The voltage drop of the line is too large
Because the output voltage of the inverter is already low when running at low frequencies, if the distance between the motor and the inverter is large, and the wire diameter of the connecting wire is thin, the line voltage drop may cause the lack of voltage on the motor side.
(2) Lack of torque improvement
In the U/f control method, the output voltage of the inverter at low frequency operation depends on the amount of torque increase. When the torque increase is small, it will lead to a lack of voltage obtained by the motor.
|
More on that
|
LS inverter frequency conversion mode
1. The operator panel is given The operator panel is a simple frequency setting method of the inverter, and the user can directly change the set rate of the inverter through the potentiometer, digital key or rising and descending keys on the inverter operator panel. The big advantage of the operator panel is that it is simple ...
|
|
The difference between overload and overcurrent of the inverter
(1) The maintenance objectives are different
Overcurrent is mainly used to maintain the inverter, whereas overload is mainly used to maintain the motor. Because the capacity of the inverter sometimes needs to be increased by one or even two gears than the capacity of the motor, in this case, the inverter is not necessarily overcurrent when the motor is overloaded.
...
|
|
Classification of the nature of DC power supply of inverter - LS power generation
A frequency converter is actually an inverter. It starts by turning alternating current into direct current. Then the direct current is switched on and off with electronic components. Becomes alternating current. Thyristors for general inverters with larger power. And set up a device with adjustable frequency. Make the frequency adjustable within a certain range. Used to control ...
|
|
Briefly describe LS ABE203b molded case circuit breaker
The circuit breaker is a fundamental low-voltage electrical appliance, which has the function of overload, short circuit and undervoltage maintenance, and has the ability to maintain the line and power supply. Circuit breaker is an indispensable product in electrical safety. Due to different applications, there are molded case circuit breakers, frame circuit breakers, miniature circuit breakers, etc.
|
|
LG Inverter-LS Inverter-IGXA Sales
LG Inverter LS Inverter IGXA Series ** for sale, its models are as follows:
SV004IGXA-4 60210101W0 Power 0.37KW (Input: 3-phase 380V / Output: 3-phase 0——380V)
SV008IGXA-4 6021010 ...
|
|
Key points of LS power BKN circuit breaker design
(1) The cooperation between the circuit breaker and the circuit breaker should consider the instantaneous trip device action value of the superior circuit breaker, which should be greater than the maximum expected short-circuit current at the outlet end of the lower circuit breaker.
|
|
Grounding of the secondary side of the voltage transformer and the current transformer - power generation
1. The transformer is grounded twice
It refers to the grounding of the S2 terminal of the current transformer or the ground of the n terminal of the voltage transformer. As long as the single point is grounded, because the transformer is blocked between the second and the first, before grounding, the secondary winding has no potential connection with the ground, after grounding, the transformer ...
|
|
Introduction of LS electric power contactors
How LS Contactor Works:
Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...
|
|
Inverter circuit board repair and drawing-free maintenance method - LS power generation
1. Be "confident"
It is necessary to fully understand the principles of some typical circuits and be familiar with them. Guangzhou Kewo Training Center believes that drawings are dead, and the thoughts in the head are alive, able to make analogies, able to reason, and able to touch analogies. For example, switching power supply is always inseparable from ...
|
|
A brief description of the K120S series plc
K120S series PLC product is a unit PLC product introduced to the market by LS in 2004, which has laid a solid foundation in the low-end small machinery supporting industry with its high-performance price ratio. Relying on some special functions of the product, it has also won some industry praise.
...
|
|
The five stages of mastery of PLC technology
One. Logical stage
The so-called logical stage is to be able to complete the general logical planning in the relay system, since it is a relay system, so the knowledge of power drag is the foundation of this stage. I personally summarize that the root of learning the relay system lies in the word "grab", the relay system ...
|
|
The working principle of LS PLC module
When LS PLC is put into operation, its operation process is generally divided into three stages: input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the ...
|
|
The power frequency motor is abnormally installed with an inverter - LS produces electricity
Installing a variable-frequency drive (VFD) on the power frequency motor can complete the accurate control and speed regulation of the motor, and improve the power and accuracy of the forward motor. However, if not properly equipped and used, it may cause the following hazards:
...
|
|
Analysis of the working principle of the inverter - LS power generation
The rectified DC voltage of the rectifier contains the pulsating voltage of the power supply 6 times the frequency, and the pulsating current generated by the inverter also changes the DC voltage.
The main power is the power replacement part of the power supply for the asynchronous motor voltage regulation and frequency modulation power supply, and the main power of the inverter can be roughly divided into two ...
|
|
The internal accessories component of the power production circuit breaker
1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.
|
|
Common practical knowledge in the inverter industry - power inverter
The inverter is the power frequency power supply (50Hz or 60Hz) converted into various frequencies of AC power supply to achieve the variable speed operation of the motor equipment, by changing the motor power frequency to achieve speed adjustment, is an ideal high-efficiency, high-speed regulation means. Frequency converters are used in industrial production and residential ...
|
|
The meaning of servo in LS power production
"Servo" - the word derives from the Greece word for "slave". People want to treat the "servo mechanism" as a handy tame thing, and act in accordance with the requirements of the control signal. The rotor stands still until the signal comes; As soon as the signal arrives, the rotor rolls; When the signal disappears, the rotor can instantly ...
|
|
Inverter external potentiometer connection method - LS power generation
The two wires are connected to the resistor, and the other wire is connected to the adjustment terminal.
The red thread is attached to the blackhead and inserted in a small hole.
Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI.
...
|
|
Several basic functions of the inverter - LS generates electricity
The inverter mainly has the following functions:
1. Soft up
The direct launch of the inverter motor will have a severe impact on the power grid, and it will also have too high requirements for the capacity of the power grid, which is extremely unfavorable to the service life of equipment and power grid circuits.
|
|
Electricity-producing permanent magnet AC contactor structure
The contactor is mainly composed of a drive system, a contact system, an arc extinguishing system and other parts.
1. Drive system: The drive system includes electronic modules, soft iron, and permanent magnets, which is an important part of the permanent magnet contactor.
|
|