Bus load guessing is a kind of power system load guessing, and the bus system load can be defined as the sum of the terminal load of a relatively small power supply area supplied by the main transformer of the substation, which is the refinement of the system load. Bus load guessing generally only carries out short-term load guessing, and the results are the basis of dynamic condition estimation, safety and stability analysis, reactive power optimization, and local control of plants and stations.
Method: According to the change law of the bus load itself and the load distribution, the former is to guess the load of the bus system by analyzing the load law of the bus system, and then correct the results, and the latter is to guess the system load to obtain the composite value of the system at a certain time, and then distribute it to each bus.
Features: In addition to guessing the active load, sometimes it is necessary to guess the martial power load. The difference in load curves between different busbars is larger. For example, the load curve of the bus with commercial load is smooth and regular, while the load curve of the steel industry is mostly zigzag, and the load change trend is not obvious. The difference in load curves between different busbars is larger. For example, the load curve of the bus with commercial load is smooth and regular, while the load curve of the steel industry is mostly zigzag, and the load change trend is not obvious.
|
More on that
|
Features of Wiener busway
The Wiener busway mainly acts on the aluminum conductor, which has a large current capacity and good electrical and mechanical properties. In addition, it uses a metal trough as the shell, so it is non-flammable, safe and reliable, and has a long service life. Compared with traditional power distribution, the equipment occupies a significantly smaller area and has a beautiful appearance.
...
|
|
Difference Between Busbar and Cable in Power System – Wiener
Busbar refers to a product made of copper (copper bar) and aluminum materials with high conductivity to transmit electric energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the electrical energy output from generators, transformers or rectifiers is delivered to individual users.
|
|
Wiener bus differential protection switching operation
1. Whether the scale of bus differential maintenance is determined, and whether the maintenance goal is unchanged
Generally, differential maintenance includes bus differential maintenance, transformer differential maintenance, generator differential maintenance and line differential maintenance. The basic principle of achieving differential maintenance is common, i.e. on all sides or on each side...
|
|
Introduction to Laminated Busbar System – Wiener
In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar.
...
|
|
The operation procedure of the dual power supply automatic transfer switch
The dual-supply ACT is a new generation of products. Beautiful appearance, good quality, long life, simple It is composed of two three-pole or four-pole shell graders and their parts/mechanical interlocking transmission arrangements, intelligent controllers, etc., which are divided into two structures: integral and split.
|
|
Calculation method of bus system and distribution cabinet bus - Wiener
The bus system divides the bus into hard bus and soft bus. The 60mm bus system refers to the three-wire or four-wire bus with a distance of 60mm.
1. In the 60mm bus system, the different cross-sectional areas of rectangular copper bars or special-shaped copper busbars such as 2T and 3T can be used to achieve the best classification of current intensity grades.
|
|
Wiener bus adapters are suitable for use with Siemens 3VA1 and 3VA2 circuit breakers
For the use of Siemens' new 3VA1 series circuit breakers in the 30Compact system with currents up to 160A, Wiener has developed an EQUES® bus adapter.
A spring-loaded base and high-performance internal power rails ensure safe connection to the circuit breaker.
advantage
...
|
|
Ship unloader distribution cabinet convergence mode - Wiener
In the hardware layout planning of the ship unloader distribution cabinet, in order to omit the wiring slot pawn, save time and effort in wiring, prevent wiring errors, and make the distribution cabinet beautiful and useful, the circuit breaker inlet end in the distribution cabinet will use the confluence method. Here are a few commonly used ways to combine the flow with Siemens circuit breakers.
|
|
Busbar wiring problems of busbars - Vernal
Bus, transformer, generator set unit wiring. It has the characteristics of simple wiring, less switchgear, easy operation, suitable for expansion, and because there is no generator outlet voltage bus, the short-circuit current of the low-voltage side of the generator and the main transformer is reduced.
...
|
|
The Wiener bus system is reliable
The bus refers to the connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices. The role of the busbar is to gather, distribute and transmit electrical energy.
...
|
|
Wiener busway specification standard parameters
1. The standard scale of the bus duct
This specification regulates the terminology, skill requirements and test methods of the insulated bus trunk system (bus duct) and its plug-in feed box (hereinafter referred to as the feed box).
This specification specification applies to additional voltage AC to 660V...
|
|
Characteristics of power system bus wiring mode
(1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, less investment, convenient operation and expansion, but its reliability and activity are poor. When the bus or bus divider is faulty or overhauled, it is necessary to disconnect all power to the bus.
...
|
|
The role of plug-in busway – Wiener
Generally speaking, plug-in busway is mainly used for power transmission. We know that all conductors will have losses, and the losses caused by the flow of electricity through conductors are larger and some are smaller. For example, compared with the aluminum wire with the same wire diameter and the copper wire, the loss of aluminum is larger, and the loss of copper is smaller. That is, the conductivity ...
|
|
NH-Fuse Type Disconnector Instructions for Use
When switching on and off components, you should pay attention to the following:
–In accordance with VDE-0105-100, only operation by electrical professionals or persons with electrical knowledge is allowed (operation without electricity, closing, disconnecting, and replacing fuses ...).
|
|
Conductor and bus welding requirements - Wiener
1. Before welding, it is necessary to check whether the welding equipment is defective, whether the grounding of the electrical equipment is reliable, and strictly abide by the "welder safety operation procedures" when welding.
2. Correct wires and busbars, and prohibit the use of handleless files.
...
|
|
Performance characteristics of low-voltage busbar system - Wienal
Introduction to the performance of low-voltage bus system:
1. The bus bar is not perforated, and is connected with the cable and copper bar through the connection clip or terminal
2. Switches, contactors and other electrical components can be directly hung on the bus through adapters
3. Save ...
|
|
Operating regulations for the use of busbars - Wiener
1. Charging to the bus should be carried out with a switch (bus tie, bypass or line switch) with snap-action maintenance that reflects various types of faults. Before charging the bus, it should be considered whether the system may be unstable if the charging bus trips, and if necessary, the active power flow of the relevant line can be reduced. ...
|
|
Structural characteristics of high-voltage busway - Vernal
If you understand the scope of application of the busway, you can see that the excellent effect of the busway has the upper hand, which has a lot to do with the structural features. Therefore, if you want to have more confidence with the bus duct, you still need to understand it from the structural characteristics. At a time when China's economy is developing rapidly, ...
|
|
How to solve the fault of the busway
If there is a problem in the bus duct of the double bus wiring, it is necessary to pay attention to the operation mode of bus maintenance in the process of dealing with the problem, and if necessary, the bus maintenance should be stopped for a short time. After the bus voltage disappears, the dispatcher should immediately swing the switch (including the bus tie switch) that may call, and notify the operation team to ...
|
|
How to choose the right fuse - Wiener
1. Select the type of fuse according to the line requirements and installation conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses.
...
|
|