Advantages of Wiener aluminum busway

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

1. Reliable insulation method

There is an insulating layer on the conductive bar, and there is a certain air yard between the phase and the phase, and there is an insulating pad block limited by DMC data between the conductive bar and the shell, and the triple insulation ensures that the insulation of the bus duct is full of certainty, especially in the humid environment.

2. Strong anti-corrosion

The aluminum profile shell has a much better galvanized anti-corrosion function after anodizing 10u, which is much better than the steel shell Japan's long-term atmospheric exposure experiments on different grades of aluminum alloy plates and galvanized copper plates, showing that its corrosion depth is about two ^ of the latter.

                               Advantages of Wiener aluminum busway

3. Reinforced aluminum alloy shell planning

The shell is made of aluminum-magnesium alloy profile, which is made of two side plates and upper and lower cover plates, and the side plate is planned with heat sink and dovetail groove, which is not only conducive to the heat dissipation of the bus duct, but also strengthens the rigidity of the shell, and also facilitates the safety and reduces the weight of the bus duct at the same time, and can plan and reduce the device bracket in a large span.

4. All grounding skills

The traditional PGA wire is placed on one side of the bus duct, because the fault current induced by electromagnetic induction on the PGD is 50% higher than the calculation of the actual measurement, and the three-phase conductive row is unequal to the PE spacing, and the inductance is unequal.

The non-magnetic material aluminum alloy shell with excellent conductivity function is selected as the protective ground wire, surrounded by the conductive bar, because it is as close as possible to the three-phase busbar, the reactance ^ is small, and the interval between the protective ground wire and the three-phase bus bar is equal, and the reactance is the same.

In this way, whether it is a short-term or a continuous short circuit to the ground, this and the grounding method are better than setting the E-row alone. Therefore, the World Electrical Skills Council issued and sold a wire transfer (busway) with a shell as the grounding conductor.

5. The device is convenient

Because the full-length appearance scale is the same, the internal structure is symmetrical, and it can be arranged as L1, L2, L3, N on either side, so the inversion is very simple and the device is convenient.

More on that
Considerations for purchasing a busbar system – Wiener Considerations for purchasing a busbar system – Wiener

The bus system plays a very important role in the practice of construction, and for products such as the bus system, the relevant items can not be ignored, so that we can better use the practical value of this type of product. Generally speaking, when we are purchasing a bus system ...

Features of the use of closed busway - Wiener Features of the use of closed busway - Wiener

Compared with other air-type busway, Wiener closed busway has many similarities in appearance, and its difference lies mainly in the shell, the structure of the closed busway is more distinctive, which also makes its use have certain advantages. As long as it is in contrast ...

Power system bus wiring features - Wiener Power system bus wiring features - Wiener

1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, small investment, convenient operation and conducive to expansion, but the reliability and flexibility are poor. When there is a fault or maintenance of the bus bar or bus barrier switch, the full power supply of the bus must be disconnected. ...

The innovation of Wiener 185Power in the low-voltage main distribution system The innovation of Wiener 185Power in the low-voltage main distribution system

The new base system adapter creates a new type of solution in combination with the 185Power system, which was not possible before. CrossBoard® products can be easily connected to the adapter of the base system via the CrossLink® interface. Components of DIN support rails, e.g. fuses ...

Characteristics of power system bus wiring mode Characteristics of power system bus wiring mode

(1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, less investment, convenient operation and expansion, but its reliability and activity are poor. When the bus or bus divider is faulty or overhauled, it is necessary to disconnect all power to the bus. ...

Structural characteristics of high-voltage busway - Vernal Structural characteristics of high-voltage busway - Vernal

If you understand the scope of application of the busway, you can see that the excellent effect of the busway has the upper hand, which has a lot to do with the structural features. Therefore, if you want to have more confidence with the bus duct, you still need to understand it from the structural characteristics. At a time when China's economy is developing rapidly, ...

Introduction to the Wiener busbar system Introduction to the Wiener busbar system

The 60mm bus system refers to the three- or four-wire bus spacing of 60mm. In the 60mm bus system, the different cross-sectional areas of rectangular copper bars or special-shaped copper busbars such as 2T and 3T can be used to achieve the optimal distribution of current intensity levels, ...

Advantages of cable tray installed in busway Advantages of cable tray installed in busway

At the time of the cable tray installation, the wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plugging ...

The difference between busway and busbar - Vernal The difference between busway and busbar - Vernal

The busway and busbar are actually closed one after the other, and the other is not closed. Closing the busbar is referred to as the busway, which means that the busway is the vest that closes the busbar, and the closing busway and the busbar refer to the same thing. ...

The common DC bus of the inverter system - Wiener The common DC bus of the inverter system - Wiener

1. Three-phase AC power supply inlet The power input of each inverter is connected in parallel on the same AC bus, and the power supply phase of the input of each inverter is consistent. In Figure 3, the circuit breaker QF is the incoming protection device for each inverter. LR is an incoming reactor, when multiple inverters are in the same ...

Applications in the power of busbar systems – Vernal Applications in the power of busbar systems – Vernal

The bus refers to the connection of voltage transformers and other voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, and most of the bare wires or stranded wires with rectangular or circular cross-sections are selected. Follow the lines ...

Wiener bearing repair technology Wiener bearing repair technology

1. Comprehensive correction of bearings The comprehensive correction of the bearing includes the comprehensive and strict correction process of the damaged bearing after cleaning, dismantling, inspection, roller table grinding or replacement of inner and outer rings, new rolling element manufacturing/original rolling element grinding, rolling element replacement, assembly, clearance adjustment and inspection and packaging.

What is tubular busbar and dense busbar - Wiener What is tubular busbar and dense busbar - Wiener

What is a tubular busbar Tubular bus bar is a kind of bus bar product with copper tube or aluminum alloy tube as conductor and external insulation. The tubular bus has the characteristics of high current (12000A), high mechanical strength, good insulation, wide application range, etc., ...

There are several main ways to wiring the Wiener bus There are several main ways to wiring the Wiener bus

Bus line refers to a product made of copper (copper bar) and aluminum material with high conductivity to transmit electrical energy and have the ability to collect and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the output of the generator, transformer or rectifier ...

Protection of medium and low voltage busbars – Wienal Protection of medium and low voltage busbars – Wienal

There are three types of maintenance commonly used in medium and low voltage bus systems: (1) Transformer backup overcurrent maintenance (typical maintenance action time is 1.2s - 1.4s) (2) Transformer voltage with feeder quick-break maintenance locking ...

The Hazards of Arc Light – Wiener Busbar System The Hazards of Arc Light – Wiener Busbar System

The arc of the switchgear cable spacing causes the pressure and temperature in the switchgear to increase rapidly, and if not removed in time, it will cause serious harm in the following aspects: (1) The arc temperature is 2 times the appropriate solar temperature, and the large ...

Distribution cabinet bus connection method - Wiener Distribution cabinet bus connection method - Wiener

When users use the distribution cabinet, they must understand the circuit device of the busbar, and many users are not very well understood, so let's talk about the bus connection mode of the distribution cabinet. The bus bar is used for the internal and external electrical appliances of the distribution cabinet.

Introduction to the classification of busway - Wiener Introduction to the classification of busway - Wiener

According to the different uses of the bus duct, the bus groove is generally composed of the start bus slot, the straight bus slot (no partition jack and jack), the L-shaped straight (horizontal) curve bus, the Z-type straight (horizontal) offset bus, the T-shaped straight (horizontal) tee bus, the X-type straight (horizontal) cross-way bus, the variable ...

What are the specific accessories of the busway - Wiener What are the specific accessories of the busway - Wiener

1. Connecting copper plates, insulating plates, and insulating piercing screws generally refer to tension spring brackets, bus connectors, connecting copper bars, and plug-in boxes. The bracket is used for buffer busbars to squeeze each other during connection, and the adapter is used for connection. The connecting copper bar is the local use of the box and the bus connection of the cabinet connection. ...

Common Bus Application Considerations – Wiener Common Bus Application Considerations – Wiener

  In the common DC bus system of multiple inverters, especially the common DC bus of inverters of different power levels, it is very important that the connection between the bus bars is maintained by fuses. When one of the inverter power equipment in the common bus is damaged by short circuit breakdown, the other inverter bus ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top