(1) Busbar
It is the basic element of the bus system, and there are a variety of standards, which can be installed with 5mm or 10mm thick rectangular busbar, double T type and triple T type busbar. The busbar is divided into 1-4 wires, 1 wire can be used with N or PE, 2 wires can be used together with N and PE, 3 wires are two-phase, and 4 wires can be used for three-phase + N or PE. The 3-wire and 4-wire bus frames are used in the auxiliary distribution cabinet of the ship unloader, and after the bus frame is installed at both ends of the busbar, the end of the bus is sealed with the end cover to ensure electrical safety. Busbar covers are used at the spare busbar, both as a protection and as a backup loop.
(2) Terminal board
It can connect the busbar, can also connect the wire, as a section of the bus system of the inlet or outlet, to achieve a straight connection between the bus and the bus bar or between the bus bar and the wire on a plane without punching, the ship unloader distribution cabinet uses the wiring board of the connecting wire and the wiring board of the connecting bus, and the wiring board is covered with a protective cover to ensure electrical safety.
(3) Bus adapter
Connecting the bus and the switch element, mainly used in the cabinet 3RV, two-pole 5SJ switch, the maximum capacity to 80A, with the adapter, the switch element can be directly hung on the bus, the operation, safe, reliable, convenient and fast. The ship unloader distribution cabinet uses a single-rail bus adapter and a double-rail rail bus adapter together. When selecting the type, try to choose an adapter with wires, so that there can be less wiring.
(4) Universal adapter
The 3VL series of high-current circuit breaker must be connected to the busbar through the corresponding universal adapter, the maximum current is 630A, and a variety of different standards and different brands of switching elements can be connected, and the 3-pole and 4-pole universal adapter is used in the ship unloader distribution cabinet, which is connected to the upper end of the circuit breaker through the screws at the upper end, and there is no need to connect the large wire.
(5) Wiring module
There is only 1 model, 01563, which can connect 1.5-16mm² wire, and the single-pole to two-pole circuit breaker that can not use bus adapter or universal adapter in the ship unloader distribution cabinet can be used within the allowable current range, and this connection module will be found to be very useful in the hardware layout planning of the distribution cabinet with bus system.
|
More on that
|
Introduction to the classification of busway - Wiener
According to the different uses of the bus duct, the bus groove is generally composed of the start bus slot, the straight bus slot (no partition jack and jack), the L-shaped straight (horizontal) curve bus, the Z-type straight (horizontal) offset bus, the T-shaped straight (horizontal) tee bus, the X-type straight (horizontal) cross-way bus, the variable ...
|
|
220V DC Hazard of Bus System – Wiener
The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system.
In the DC system, the positive and negative poles of the DC are insulated from the ground, and when the ground of one pole is generated, there is no grounding current due to the fact that there is no grounding current.
|
|
Advantages and disadvantages of bus full differential protection
Thorough differential maintenance of the bus is to connect the current transformer of all the connecting elements on the bus to the differential circuit according to the same name phase and polarity, the characteristics and transformation ratio of the current transformer should be the same, if the transformation ratio can not be together, the compensation converter can be used to compensate, satisfactory ΣI=0.
...
|
|
Characteristics of single bus wiring in the switchgear - Wiener
In power distribution equipment such as voltage distribution cabinets and switchgear at all levels of power plants and substations, the conductors connected between large electrical equipment such as generators and transformers and various electrical equipment are called busbars. Busbars, also known as busbars, are used to gather, distribute, and transmit electrical energy. The connection methods of the bus bar are ...
|
|
Advantages of pluggable busway
1. The plug-in bus duct has strong overload capacity
The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105 is selected for the insulation data used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed.
|
|
Wiener busway plug-in box wiring method
The bus duct bracket has to be firmly installed, and the bus duct should be correctly placed according to the segment sequence number, phase sequence, number, direction and device mark, and when the sections are connected, the adjacent section of the bus duct should be aligned, and the conductor and shell of the bus duct should not accept mechanical stress after the connection.
...
|
|
The difference between metal busbar and closed busbar - EVOC
The nature is different
Busbar: It is a common path on which multiple devices are connected in the form of side-by-side branches.
Busway: It is a closed metal equipment composed of copper and aluminum busbars.
Different uses
Mother...
|
|
Introduction to several power supply systems – Wienal
At present, China has five power supply systems: IT, TT, TN-c, TN-c-s and TN-S. They have their own advantages and disadvantages, and we should choose sensitively according to the actual situation in life.
Five power supply systems
1.IT power supply system
In a ...
|
|
Wiener bus adapters are suitable for use with Siemens 3VA1 and 3VA2 circuit breakers
For the use of Siemens' new 3VA1 series circuit breakers in the 30Compact system with currents up to 160A, Wiener has developed an EQUES® bus adapter.
A spring-loaded base and high-performance internal power rails ensure safe connection to the circuit breaker.
advantage
...
|
|
Uses and characteristics of busbar systems – Wienal
The bus system is a system with standardized bus distance, which is used in low-voltage power supply and distribution switchgear and control equipment, so that the bus can play the effect of conducting electricity and supporting electrical components.
The system is divided into 40, 60, 100 and 185mm ...
|
|
The advantages of busway are used in cable tray installations
At the time of the cable tray installation, the wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows:
1. Convenient connection of bus duct: the so-called plug-in bus...
|
|
What is the difference between a Wiener busbar and a cable
The difference between busbar and cable
The busbar is used to gather current. Many power and power supply circuits are connected to the bus, through which the power is gathered and sent to each circuit. Therefore, the current carrying capacity of the bus bar is relatively large, and the current carrying capacity of the bus ...
|
|
Aluminum alloy busway circuit continuity - Wiener
The continuity of the aluminum alloy bus duct maintenance circuit is related to the PE line, and the crossover PE wire conductor bus of the maintenance conductor and the two-unit bus bar should reach 50% of the phase line, the equivalent cross-sectional area. The continuity resistance of the housing and PE line maintenance circuit is ≤ 0.005 ohm female, and the unit with jumper wire is not less than the maintenance conductor.
|
|
The difference between busway and silicone rubber inverter cable - Vernal
The internal bus duct uses high-quality T2 electrolytic copper as the transmission conductor, which has high purity, high conductivity, low loss and small heating, which is very suitable for industrial and mining enterprises that need large current load operations.
|
|
Precautions for the operation of low-voltage cabinets - Wienal
1. To carry out work in all and part of the energized panels, the equipment should be overhauled and separated from the operating machinery and equipment with obvious markings.
2. The secondary winding of the voltage transformer and the transformer should have reliable grounding maintenance.
3. On the secondary circuit of the voltage transformer in operation...
|
|
Difference Between Grounding Electrode and Grounding Busbar – Vernal
The grounding electrode is a discharge channel that connects current or voltage to the earth, and in order to reduce the grounding resistance, the electrodes that form the grounding grid are generally used in groups.
The grounding bus refers to the connecting wire that connects the current or voltage to the grounding grid, or the conductor that connects the grounding electrode into one.
...
|
|
The way in which the Wiener high-voltage busway is selected
In the selection, the following elements should be fully considered: fire protection specifications, insulation layer to flame retardant, good temperature resistance, high temperature is not easy to release harmful gases, structure type to avoid chimney effect, should give priority to the use of aggregate insulation layer bus duct, such as the use of air insulation type, it must be in the electric ...
|
|
Features of busway power supply system - Wiener
1. Trunk power distribution system, simple wiring and reliable operation.
2. It is convenient to tap, and you can tap without cutting off the main power supply. Large power supply capacity up to 6300A current-carrying capacity.
3. High dielectric strength, strong overload, superior fire performance. Good heat dissipation performance, low impedance ...
|
|
The busway power system is a key component - Wiener
The busway is one of the more critical components in the power system, and it is an important part of connecting cables to important equipment such as substations, overhead lines, transformers, circuit breakers, etc. It is widely used in various power systems, mainly for the reliable operation of power systems.
...
|
|
Specific optimization application of ship unloader bus system - Wiener
1. Bus system 1