The naming of solid state relay models has not been unified, and the following conditions should be considered when selecting the manufacturer's manual.

(1) Rated input voltage

Refers to the maximum allowable effective voltage of a steady-state resistive load that can be withstood under a given condition. When used in inductive loads, the selected rated input voltage must be greater than twice the value of the supply voltage, and the breakdown voltage of the selected product should be more than twice the peak value of the load supply voltage. The AC load is a resistive load of 220V, and SSR of 220V voltage level can be selected; For inductive load with AC load of 220V or resistive load with AC load of 380V, SSR with voltage level of 380V can be selected; The AC load is an inductive load of 380V, and SSR of 480V voltage level can be selected; The forward and reverse rotation of the motor can choose the SSR of 480V voltage level; For single-phase or three-phase motor loads with frequent starts, SSR with voltage level of 660-800V can be selected.

(2) Rated output current and inrush current

The rated output current refers to the maximum RMS current that can be withstood under a given condition (ambient temperature, rated voltage, power factor, presence or absence of heat sink, etc.). Solid state relays are very sensitive to temperature, and after the operating temperature exceeds the nominal value, they must be derated or used with an external heat sink, and usually manufacturers provide thermal derating curves.

Inrush current is the maximum non-repetitive peak current allowed under a given condition (ambient temperature, rated voltage, rated current, duration of time, etc.) without causing permanent damage. For resistive loads, SSR can be used in full or with a derating of 10%. The inrush current of electric heater and contactor can reach 3 times of the steady-state current at the moment of switching, and the SSR should be reduced by 20%-30%.

Use and maintenance of solid state relays

When wiring the solid state relay, do not reverse the output and output termination. Please pay attention to the following precautions when using it.

(1) The influence of inrush current on SSR All loads have inrush current when working, such as the electric heating element is a pure resistive load, with a positive temperature coefficient, the resistance is smaller at low temperature, and the current is larger when the initial power is on. If the heat inside the SSR does not have time to dissipate, it may damage the thyristor, so it is necessary to leave a certain amount of current margin when choosing the SSR. When using resistive and electric thermal loads, the current level of SSR should be 2-2.5 times greater than the rated current of the load.

(2) The influence of the ambient temperature of the use of the load capacity of the solid state relay is greatly affected by the ambient temperature and its own temperature rise, the use of good heat dissipation conditions, the rated working current of more than 10A SSR should be equipped with a radiator, more than 100A SSR should be equipped with a radiator plus fan for strong cooling. When installing, pay attention to the good contact between the bottom of the SSR and the radiator, and apply thermal grease. SSRs operating at 40-80°C for a long time should be derated at the current level.

(3) Over-current and over-voltage protection measures Over-current and load short circuit will cause permanent damage to the SSR, and a quick fuse and air switch should be set in the control loop for protection, and the RC absorption loop and varistor can be connected in parallel at the output of the SSR for protection.

(4) Input loop signal

If the input voltage or input current exceeds the specified limit, the voltage divider resistor can be connected in series at the input terminal or the shunt resistor in parallel at the input terminal to make the input signal meet the requirements of SSR. The input signal line should be kept away from the source of electromagnetic interference to prevent malfunction.
Peel Magnetic Relays – How to Choose a Solid State Relay


More on that
Pilz: Guard locking and safety interlocks in functional safety Pilz: Guard locking and safety interlocks in functional safety

In machinery safety, if it is an access door that prevents entry into the hazardous movement area, it is usually necessary to use a safety interlock switch to realize the "linkage" between the access door and the movement of the hazardous equipment, and when the access door is opened, the dangerous movement stops. In some cases, it is also necessary to prevent the access door from being hit.

Introduction to the appearance and terminal blocks of the Pilz safety relay PNOZ s5 Introduction to the appearance and terminal blocks of the Pilz safety relay PNOZ s5

PNOZ s5 belongs to the PNOZSigma family and is a safety relay with a time-delay function There are 8 terminal blocks on the top and bottom of the module, where: A1 and A2 are the terminal blocks of the module power supply; S11 and S12 are terminal blocks for a set of safety input channels; S21 and ...

Pilz: Safety control solution for SIL4 at rail level crossings Pilz: Safety control solution for SIL4 at rail level crossings

On fully enclosed rail transit lines, viaducts or tunnels are usually used to avoid the impact of rail lines on the distance, while on non-fully enclosed rail transit lines, the plane intersection between the railway and the distance, that is, level crossings, is more common. In the early stage, rail transit ...

Pilz: Cleared! The risks of the canning line are "gone" Pilz: Cleared! The risks of the canning line are "gone"

Today we share with you the case of ACMI S.p.A., an Italy company dedicated to the production of high-end filling and packaging lines, to see how they do the safety protection of canning lines.   Let's start with their process...... This mineral water filling ...

PILZ WILL BE EXHIBITING AT THERMPROCESS 2023 PILZ WILL BE EXHIBITING AT THERMPROCESS 2023

From June 12 to June 16, 2023, Pilz will be present at the THERMPROCESS trade fair in Düsseldorf, Germany, at booth B10 in Hall 9. Germany Düsseldorf Thermprocess is Germany most important trade fair for industrial furnaces and heat treatment ...

Pilz Switches - Introduction to the use, characteristics and functions of high-voltage load switches Pilz Switches - Introduction to the use, characteristics and functions of high-voltage load switches

(1) Use The high-voltage load switch is an electrical appliance with a function between the high-voltage circuit breaker and the high-voltage isolation switch, and the high-voltage load switch is often used in series with the high-voltage fuse; It is used to control power transformers. The high-voltage load switch has a simple arc extinguishing device, because it can turn on and off ...

Pilz: The best helper for safety control systems Pilz: The best helper for safety control systems

The safety control system generates a large amount of data at all times while ensuring the safety functions of its equipment. For example, when the E-STOP button is pressed, when someone opens a certain safety door, who switches the machine to service mode when, etc. This data is important for device managers ...

Selection and features of Pilz safety relays Selection and features of Pilz safety relays

Selection and features of Pilz safety relays: 1. Understand the necessary conditions first The power supply voltage of the control circuit, the maximum current that can be delivered; voltage and current in the controlled circuit; How many sets of contacts and what form of contacts are required for the controlled circuit. Choosing the following ...

Peel magnetic relays - what are the connection methods of relays? Peel magnetic relays - what are the connection methods of relays?

1. 3-pin relay wiring The common 3-pin relay is the car horn relay. No. 1 is the contact terminal, which connects the load; No. 2 is the common terminal between the contact and the coil, which is connected to the power supply; No. 3 is the coil terminal, which connects the button switch (such as the horn on the steering wheel).

Pilz: New system version PSS 4000 1.24 Pilz: New system version PSS 4000 1.24

The automation system PSS 4000 offers new features in the new version 1.24. Here's what you need to know:   New data types FIXED and LFIXED The data types FIXED (a fixed digit with 6 decimal places) and LFIXED (a fixed number with 11 decimal places) are now ...

Peel magnetic relays – what do you need to do when equipping your machine with a safety light curtain? Peel magnetic relays – what do you need to do when equipping your machine with a safety light curtain?

1. Choose the correct encoder model 2. Build the right safety loop 3. There is no blind spot in the installation of safety light curtains 4. The safety distance of the safety light curtain meets the requirements of EN ISO 13855 ...

Pilz: The path of innovation that began with the "mouse connection". Pilz: The path of innovation that began with the "mouse connection".

The debut of "Mouse Wire" in the world of automation dates back to 2002 at the SPS trade fair in Nuremberg, where Pilz presented users for the first time with a configurable small safety controller: no need to know a "higher-level" programming language, thanks to the ease of operation, the graphical ...

Pilz safety switches – wiring methods for safety switches Pilz safety switches – wiring methods for safety switches

1. The switch binding post is generally marked with L, L1, L2. When the L end enters the line, L1 and L2 have one end and L on, and after pressing the switch, the other end of L1 and L2 is connected to L. 2. Peel the thread with diagonal pliers first, and be careful not to leave too long the thread to avoid touching. 3. To the left ...

Pilz: It's easy to build your own customised safety relay Pilz: It's easy to build your own customised safety relay

The myPNOZ Creator online tool, the configurator for the modular configurable safety relay myPNOZ, can be used via a PC with an Internet connection and no need for local installation in advance. Find the entrance to myPNOZ Creator on this page and start an extraordinary experience. ...

Pilz: Conventional mechanical risks of hydraulic presses and how to prevent them effectively Pilz: Conventional mechanical risks of hydraulic presses and how to prevent them effectively

With the rapid development of industrial technology, on-site equipment is also developing towards a high degree of integration and automation. But no matter how the technology develops, behind the dazzling technology, the basic common equipment is always a solid backing. The hydraulic press is one of the old industrial basic equipment, and it is almost ...

Peel magnetic relays – how thermal relays control contactors Peel magnetic relays – how thermal relays control contactors

The main function of a thermal relay is to protect the motor. The new electronic thermal relay has protection against overload, overcurrent, blocked rotor and various phase faults, current unbalance, interphase short circuit, inter-turn short circuit or overvoltage, undervoltage and so on. In the process of using thermal relays, we should ...

How Pilz safety relays work How Pilz safety relays work

PILZ SAFETY RELAYS GENERALLY CONSIST OF AN IRON CORE, COILS, ARMATURES, CONTACT REEDS, ETC. As long as a certain voltage is added to both ends of the coil, a certain current will flow through the coil, resulting in an electromagnetic effect, and the armature will overcome the tensile force of the return spring under the action of electromagnetic force attraction to ...

Pilz: Here comes an alternative to tagout lockout Pilz: Here comes an alternative to tagout lockout

The repair and maintenance of industrial field equipment is inevitable, and the most embarrassing thing for field personnel is that the equipment is started while the person is still in the danger area. In this scenario, personnel are highly vulnerable to serious injuries from moving parts, harmful gases, harmful rays, and high temperatures. Listing...

Peel magnetic relays – the difference between solid state relays and mechanical relays Peel magnetic relays – the difference between solid state relays and mechanical relays

1. The structure/working principle of the two is different Mechanical relays consist of an iron core, coils, and contacts. When the coil is energized, the current in the coil generates a magnetic field that makes the contacts act, thus completing the working principle of the mechanical relay. Solid state relays are made up entirely of electronic components. That...

ANALYSIS OF THE WORKING PRINCIPLE OF PILZ SAFETY RELAYS ANALYSIS OF THE WORKING PRINCIPLE OF PILZ SAFETY RELAYS

Germany Pilz automatic switching element with isolation function PILZ relay: PILZ relay is an automatic switching element with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the important control components. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top