1. Lower limit deviation alarm setting: Press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. Upper limit deviation alarm setting: press the SET key to select "SHP", the green display shows the value of the parameter, select the shift, increase, decrement shortcut setting or modify the parameter, the parameter indicates that the alarm point is higher than the difference value of the main control without fixed point.
3. The ratio range is not set: the 5 selection displays", the green display shows the value of the parameter, and selects the shift, increase, subtraction setting or modify the parameter. The larger the temperature controller, the lower the sensitivity of the electrical output of the soil control line, and the smaller the value of "", the higher the sensitivity of the main control relay output of the thermostat.
4. Integral time setting: select and display according to SET"
The green display shows the value of the parameter, and you can select the shift, increment, or decrement keys to set or modify the parameter. The shorter the set integration time, the stronger the integration effect.
5. Differential time setting: press the SET key to select "D", the green display screen displays the value of the parameter, and select the shift, increment, decrement key to set or modify the parameter. The longer the differential time set by the instrument, the stronger the correction will be made by differentiation.
6. Proportional period setting: press the SET key to select and display "T", the green display screen displays the value of the parameter, and select the shift, increment, decrement key to set or modify the parameter.
7. Self-tuning settings: select and display "Ar" according to SET, display the value of the parameter in green, select bits, increments, increments to set or modify the parameter to "00" to indicate that the self-tuning is off, and set to 01 means to start the auto-tuning.
8. Teaching settings: press the SET key to select and display "LOK", the green display screen shows the status of the lock, select the shift, increment, and decrement keys to set or modify the teaching method: set to "00" table is not locked, and "01" table is not locked to teach Shihan, set
A value of 02 indicates that all parameters are locked. After the parameter is locked, others cannot modify it, and when it needs to be modified, it must be unlocked, that is, it is set to "00"
9. The upper limit of the main control temperature setting: Press the SET key to select the value of the SOH green display to display multiple parameters, and elect the position, increase, speed urban construction setting or township to participate in the teaching, the parameter indicates that the action temperature of the soil control electrical appliance is not confident in the value, otherwise, the main control temperature is invalid
10. Temperature correction setting: Press the SET key to select and display "SC", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter; This function can be used to correct the measurement deviation after a long period of operation of the thermostat. If the measured value is 2°C smaller, you can set this parameter to 02, if the measured value is 2°C, you can set this parameter to -2.
|
More on that
|
RKC thermostat - introduction of the three output modes of the thermostat
The first output method is relay output, which is output for temperature control through the switching signal of the relay on/off, which is used to directly control the load less than 5A, or directly control the contactor and the intermediate relay, and control the high-power load externally through the contactor.
The second ...
|
|
How to set the parameters of the RKG thermostat - intelligent digital display controller?
1. First of all, the digital display should be installed on the cabinet, so the overall coordination should be considered, too large may not fit, too small to see the display numbers.
2. In addition, the large size of the instrument is generally more expandable, the same function price may be expensive, the small size of the instrument may be ...
|
|
RKG thermostat - an introduction to the relevant knowledge of temperature controllers
The temperature controller is an electrical switchgear that controls the temperature of an air-conditioned room. The temperature range in the air-conditioned room controlled by the temperature controller is generally 18°C--28°C. The temperature controller commonly used in window air conditioners uses the principle of pressure to push the contacts on and off. Its structure consists of bellows ...
|
|
RKC Level Gauge – The structure of a float level gauge
(1) For the indicator, also known as the display panel, the indicator plays the role of local display, convenient for long-distance observation of the actual situation of the liquid level, the indicator is generally bundled with the pontoon, easy to install.
(2) It is a magnetic float, which is located in the pontoon and is in direct contact with the liquid to be measured, ...
|
|
Key features of the RLC thermostat:
Thermocouples, RTDs, analog and other signals are freely inputted, and the range can be set freely;
The software zeros the full degree, the cold end measures the temperature separately, the amplifier is self-stabilizing, and the display accuracy is better than 0.5%FS;
Fuzzy theory combined with traditional PD method, fast and stable control, advanced tuning ...
|
|
RKC Level Gauge – Buoy Level Gauge Use and Precautions
1. Support welding under the guidewire:
According to the direction of the movement of the buoy of the level gauge, determine the position at the bottom of the container, and fix the guide bracket (piece 1) under the welded or riveted steel wire
2. Install the guide rail joint.
(1) Straighten the wire forcefully and fix it at the lower support, taking care not to ...
|
|
RKC Level Gauge – The correct maintenance method for float level gauges
(1) After 6 months to 1 year of operation, the sensor should be visually inspected and routinely calibrated.
(2) Regularly check whether the sensor is bent and deformed by external force to avoid ball jamming.
(3) Regularly check whether the magnetic induction switch element of the sensor is aging and failing, ...
|
|
Common faults and solutions of intelligent temperature controllers - RTC
Master the common problems of several common intelligent temperature controllers, and solve them by yourself when you encounter problems, and you don't need to spend time and effort to find someone to repair, the common problems are as follows:
1. Heating for a period of time, the temperature does not change. Ambient temperature (e.g., room temperature 25°C) is displayed at all times
...
|
|
RRKC thermostats – the commissioning steps of mechanical thermostats
1. Confirm the angle sample first. See where the angle of the sample is today.
2. Pick up the thermostat, first confirm whether the switch of the thermostat is tight, stuck, whether the white dot falls off, whether there is sound when the thermostat contacts are in contact, and if there is no sound, there should be two possibilities!
...
|
|
RKC thermostat - how to set the parameters of the thermostat?
1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. The upper limit deviation alarm is set ...
|
|
RRKC thermostat – the correct way to set up the thermostat
Press the SET button to set or view the temperature set point, press the SET key digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The instrument returns to normal working condition ...
|
|
The debugging method of the temperature controller
Generally, there are three buttons to provide the need for setting, one is the Set button, press it once to enter the setting state. The other two offer upward and downward temperature adjustments, which can be adjusted to any temperature point. After adjusting to the desired temperature point, press the Set button again to confirm.
1. Turn on the smart thermostat ...
|
|
How to set the parameters of the RKC fb900 thermostat
Model definition
FB90②③*④4⑤⑥⑦⑧⑨-0(
CODE 8N-4*4NN5/A1-F801/Y
control
"(1)(2)" indicates Output 1 and Output 2 classes
M: Relay output V: Voltage pulse output 5: 0-10V
8: 4-20mAN: No output
“ ...
|
|
RKC thermostat REX-C400 model settings and parameter instructions
Japan RIKA RKC REX-C400 temperature controller product introduction
REX-C400 Digital Thermostat RKC PID Temperature Controller Thermostat (SSR Output) + Type K Thermocouple + *Large 40A SSR Relay
1. Dual display set temperature and process temperature
2. General Digital Programmable Temperature ...
|
|
RKC Level Gauge - Preservation and storage of float level gauges in daily use
1. To avoid damage to the instrument, pay attention to the correct protection method: in order to ensure the accuracy of the instrument and avoid damage to the instrument, try not to use the protection instrument of isolator or other isolation devices. If you have to do it, you should also pay attention to the careful selection, determine the isolation solution, and wash the isolation film correctly, ...
|
|
What are the precautions for the installation of the RKG thermostat?
1) For RTD input, 3 wires with low resistance and no difference should be used.
2) The input signal line should be far away from the power line of the instrument. Power supply and load lines to prevent noise disturbances.
3) The power cord of the instrument is generally disturbed by the power supply.
4) Instrument complement ...
|
|
RKC Temperature Control Meter - How to set the temperature control meter
1. Turn on the power supply of the smart thermostat, and the temperature displayed on the screen is the temperature at that time. Because the sensor is not in contact with other devices, but is directly exposed to the air clock, this is the current temperature: 31 degrees Celsius, which is not too hot.
2. At the bottom right of the display screen is the "starting temperature" setting ...
|
|
RLC thermostat - a classification introduction of floor heating thermostats
Floor heating thermostats can be divided into digital thermostats and analog thermostats according to different input and output forms. Digital thermostats generally have liquid crystal display or digital tube display panels, and set and control the temperature through buttons, while analog thermostats generally use knobs or slider band wave wheels to set ...
|
|
How to set the parameters of the RKC rs400 thermostat?
1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key data will change rapidly, press the SET key again ...
|
|
RK Level Gauge - Four common types of faults and solutions for float level gauges
1. The indicated value is large (or out of range).
According to the investigation of our staff, this kind of problem often appears in the atmospheric pressure workshop. When we find that the counterweight of the float in the float level gauge is at a low point, the liquid level must be very high at this time, and the glass plate is inconsistent with the indication of the instrument.
|
|